TEXIO PA18-2B, PA18-3B, PA18-1.2B, PA18-5B, PA36-1.2B Instruction Manual

...
©PRINTED IN JAPAN B71-0116-10
INSTRUCTION MANUAL
REGULATED DC POWER SUPPLY
PA-B SERIES
PA10-5B PA18-1.2B PA18-2B PA18-3B PA18-5B PA36-1.2B PA36-2B PA36-3B PA80-1B PA120-0.6B PA160-0.4B PA250-0.25B
PA250-0.42B PA350-0.2B PA600-0.1B
CONTENTS
USING THE PRODUCT SAFELY ..................................................-
1OUTLINE AND FEATURES_________________________________1
2SPECIFICATIONS ________________________________________2
3. INSTRUCTIONS ON USE _________________________________ 10
3-1. Checking Source Voltage...........................................................................10
3-2. Connection of Power Cable.......................................................................10
3-3. Precautions for Connecting Output Terminals.........................................10
3-4Switches on Front Panel and Connection Terminals on Rear Panel....11
3-5Digital Display .............................................................................................11
3-6. Switching Points of Relay...........................................................................11
3-7. Installation Environments ...........................................................................12
3-8. Rack Mounting ............................................................................................13
3-9. Options.........................................................................................................14
4PANEL EXPLANATION ___________________________________15
4-1. Front panel...................................................................................................16
4-2Rear panel...................................................................................................19
5. OPERATION PROCEDURES ______________________________21
5-1Independent Operation..............................................................................21
5-2Remote Sensing.........................................................................................21
5-3OVP..............................................................................................................22
5-4Remote Control Functions.........................................................................23
5-5Output ON/OFF Remote Control..............................................................25
5-6Constant-Voltage Remote Control............................................................26
5-7Constant-Current Remote Control............................................................29
5-8Status Signals .............................................................................................32
5-9. Monitoring Voltage and Current.................................................................33
5-10.Series and Parallel Connections ............................................................34
5-11.One-Control Parallel Operation...............................................................36
5-12.Recharging Battery.................................................................................38
6. TROUBLES AND PHENOMENA ____________________________39
7.EXTERNAL DIMENSIONS FIGURE _________________________40
This instruction manual applies to fifteen models: PA10-5B, PA18-1.2B, PA18-2B, PA18-3B, PA18-5B, PA36-1.2B, PA36-2B, PA36-3B, PA80-1B, PA120-0.6B, PA160-0.4B, PA250-0.25B, PA250-0.42B, PA350-0.2B, and PA600-0.1B. The operation procedures, etc. described in this manual are common to all models, except some difference in the specifications. Please refer to the descriptions about the purchased model.
I
USING THE PRODUCT SAFELY
Preface
To use the product safely, read this manual to the end. Before using this product, understand how to correctly use it. If you read this manual but you do not understand how to use it, call the company that is indicated on the back cover of this manual. After you read this manual, keep it so that you can read it anytime as required.
Notes on reading this manual
The contents of this manual include technical terms in part of their explanation. If you do not understand those terms, do not hesitate to ask the company or each distributor.
Pictorial indication and warning character indication
This manual and product show the warning and caution items required to safely use the product. The following pictorial indication and warning character indication are provided.
<Pictorial Indication>
Some part of this product or the manual
may show
this pictorial indication. In this case, if the product
is incorrectly used in that part, a serious danger may
be brought about on the user's body or the product.
To use the part with this pictorial indication, be sure
to refer to this manual.
<Warning character Indication>
WARNING
CAUTION
If you use the product, ignoring this indication, you
may get killed or seriously injured. This indication
shows that the warning item to avoid the danger is
provided.
If you incorrectly use the prod
uct, ignoring this
indication, you may get slightly injured or the product
may be damaged. This indication shows that the
caution item to avoid the danger is provided.
Please acknowledge beforehand that our company does not assume the responsibility at all except when the liability for damage in the law is admitted for the user or the third person’s misuse, abuse, neglect, unauthorized product modification or failure to follow this manual, and other troubles, or any damages caused by use of this product.
II
USING THE PRODUCT SAFELY
WARNING
Do not remove the product's covers and panels
Never remove the product's covers and panels for any purpose. Otherwise, electric shock to the users or a fire may be incurred.
Warning on using the product
The warning items given below are to avoid danger to the user's
body and life and avoid the damage and deterioration of the product.
Use the product, observing the following warning and caution items.
Warning item on installation environment
Operating temperature
Use the product within the operating temperature indicated in
the rating column. If the product is used with the vents of the product blocked or in high ambient temperatures, a fire may occur.
Operating humidity
Use the product within the operating humidity indicated in the
rating column. Watch out for condensation by a sharp humidity change such as transfer to a room with a different humidity. Also, do not operate the product with wet hands. Otherwise, an electric shock or fire may occur.
Use in a gas Use in and around a place where an inflammable or explosive
gas or steam is generated or stored may result in an explosion and fire. Do not operate the product in such an environment.
Also, use in and around a place where a corrosive gas is
generated or spreading causes a serious damage to the product. Do not use the product in such an environment.
Do not let foreign matter in
Do not insert metal and flammable materials into the product
from its vent and spill water on it. Otherwise, an electric shock and fire may occur.
III
USING THE PRODUCT SAFELY
WARNING
Warning about Power Source
Input Power
Check the source voltage before using the PA-B series. The product has an input voltage selector switch above the AC inlet on the rear panel. The figure below shows the source voltage of the PA-B series. Note that using the PA-B series on different voltage may result in a trouble or breakdown. Check the switch, and connect the power cable to the AC outlet.
Power Cable
IMPORTANT: The power cable set supplied with the PA-B series
is unusable for any other product.
Using a power cable not supplied with the PA-B series may result
in electric shocks, electrocution or a fire. If the power cable set supplied with the PA-B series is damaged, stop using the PA-B series and contact our distributor. Using the PA-B series with the damaged power cable may result in electric shocks, electrocution or a fire. The power cable set supplied with the PA-B series is to be used for 220 VAC power. Contact the distributor if you intend to use the PA-B series on input voltage other than 220 VAC.
The fuse for protection
The product doesn't operate when the fuse for input protection is blown. Users can replace the fuse by themselves according to some instructions including cautions and remarks on the user’s manual. It is important to be very careful to keep the instructions strictly without fail. Misplacing may cause danger of fire.
220
V
IV
USING THE PRODUCT SAFELY
WARNING
Warning item on grounding
The product has the GND terminal on the panel surface to protect the user from electric shock and protect the product. Be sure to ground the product to safely use it.
Warning item on abnormality while in use
If smoke or fire is generated from the product while in use, stop using
the product, turn off the switch, and remove the power cord plug from the outlet. After confirming that no other devices catch fire, call the company or our distributor.
CAUTION
Connection of Remote Control Input and Output Terminals
The maximum input rating of the remote control input and
output terminals is determined in order to avoid damages to the product. Do not input or output voltage/current exceeding the rating described in the instruction manual. Excessive input or output may cause a trouble or breakdown of the product.
When the voltage or current is controlled according to external
voltage, the negative (-) side of the external voltage unit is connected with the -S output terminal of the PA-B series. Use the output circuit of the external voltage unit in the condition where it is floated from the frame in order to avoid accidents or malfunctioning. When several power supply units are used for a remote control application, each external power supply unit must be floated.
The negative (-) side of the voltage/current monitor terminal is
internally connected with the -S terminal. Use the input circuit of the external measuring instrument in the condition where it is floated from the frame in order to avoid accidents or malfunctioning.
V
USING THE PRODUCT SAFELY
CAUTION
Input/output terminal
Maximum input to the input terminals is specified to prevent the product from being damaged. Do not supply input, exceeding the specifications that are indicated in the "Rating" or "Caution on use" column in this manual of the product. Otherwise, a product failure is caused. Also, do not supply power to the output terminals from the outside. Otherwise, a product failure is caused.
When the product is left unused for a long time
Be sure to remove the power plug from the outlet.
<Calibration>
Although the performance and specifications of the product are checked under strict quality control during shipment from the factory, they may slightly change because of secular changes in its parts. It is recommended to periodically calibrate the product so that it is used with its performance and specifications stable. For consultation about the product calibration, call the distributor or the company where you bought the product.
<Daily maintenance>
When you clean off the dirt of the product covers, panels, and knobs, avoid solvents such as thinner and benzene. Otherwise, paint may peel off or the resin surface may be affected. To wipe off the covers, panels, and knobs, use a soft cloth with neutral detergent in it. During cleaning, be careful that water, detergents, and other foreign matters do not get into the product. If a liquid or metal gets into the product, an electric shock and fire are caused. During cleaning, remove the power cord plug from the outlet.
Use the product correctly and safely, observing the above warning and caution items. Because this manual indicates caution items even in individual items, observe those caution items to correctly use the product. If you have questions or comments about the content of this manual, call the distributor or the company.
1
1OUTLINE AND FEATURES
The PA-B series is a high-performance DC constant-voltage, constant­current power supply unit with 3 1/2-digit voltage indicator LEDs and 3-digit current indicator LEDs. The series regulator control allows the user to vary the output from 0 to the rated output. The output controller, a 10-turn winding type variable resistor, offers fine control of output voltage and current. It is possible to set the output voltage and current even when the output is off. The output voltage and current may be checked on digital indicators simultaneously. The PA-B series are high-cost-performance power supply units with output On/Off, output sensing and various remote control functions and fully meet various users' needs. They have a wide variety of applications such as power supplies for researches and development, power supplies for aging, and fixed power supplies for many systems according to purposes.
- Low-Ripple and Low-Noise Power Supply Unit The series regulator control system eliminates ripples and noises to quite low levels and provides low temperature coefficient and superior electrical performances.
- Simultaneous Voltage and Current Digital Display LEDs
3 1/2-digit automatic-range voltage indicator LEDs (fixed range indicators on the PA18-1.2B, PA18-2B, PA18-3B, PA18-5B, PA120-0.6B and PA160-0.4B) and 3-digit current indicator LEDs enable simultaneous check and setting of the voltage and current. The LEDs give indications in green in the constant-voltage mode and in red in the constant-current mode.
- Increased Output in Series/Parallel Operation Series connection increases the output voltage (except the PA350-0.2B, and PA600-0.1B). Parallel connection increases the output current. One-control parallel connection allows control of several slave power supply units from a single master power supply unit.
- With Floating Output/Voltage Remote Sensing Terminal The output terminal is a floating type terminal and may be used in the positive or negative polarity. A voltage remote sensing terminal is provided on the front panel for fine control of the load terminal voltage (except the PA80-1B, PA120-0.6B, PA160-0.4B, PA250-0.25B, PA250-0.42B, PA350-0.2B and PA600-0.1B).
- Various Remote Control Terminals for Systematization The PA-B series have various remote control terminals, which allow the output to be turned on or off or fixed using external contact signals and the output voltage or current to be remote-controlled according to external voltage (0 to 10 V) or input resistance (0 Ω to 10 kΩ).
2
2SPECIFICATIONS
Item PA10-5B PA18-1.2B PA18-2B PA18-3B PA18-5B PA36-1.2B PA36-2B PA36-3B
OUTPUT
Output voltage 0 to 10V 0 to 18V 0 to 36V
Resolution (logical value) 1.8mV 3.3mV 6.5mV
Voltage setting dial 10 Rotary
Output current 0 to 5A 0 to 1.2A 0 to 2A 0 to 3A 0 to 5A 0 to 1.2A 0 to 2A 0 to 3A
Resolution (logical value) 0.9mA 0.3mA 0.4mA 0.6mA 0.9mA 0.3mA 0.4mA 0.6mA
Current setting dial 10 Rotary
CONSTANT VOLTAGE CHARACTERISTICS CV
Input regulation
For ±10% variance of source voltage *1
1mV 1mV 2mV
Load regulation
For 0V to 100% variance of output current *1
5mV 2mV 2.5mV 3mV 5mV 2mV 3mV 4mV
Ripple and noise
rms10Hz to 1MHz *2
0.5mV
Transient response
typcurrent 10% to 100%
*3
50us typ
Temperature coefficient
typ 100ppm/°C typ
Rise time
Full load/No load typ
100ms/100ms
Fall time
Full load/No load typ
50ms/1s
Remote control
External voltage/
output voltage ratio
Approx.
10V/10V
Approx. 10V/18V Approx. 10V/36V
Remote control
External resistance/
output voltage ratio
Approx.
10kΩ/10V
Approx. 10kΩ/18V Approx. 10kΩ/36V
3
Item PA80-1B PA120-0.6B PA160-0.4B PA250-0.25B PA250-0.42B PA350-0.2B PA600-0.1B
OUTPUT
Output voltage 0 to 80V 0 to 120V 0 to 160V 0 to 250V 0 to 350V 0 to 600V
Resolution (logical value) 14.4mV 21.6mV 28.8mV 45.0mV 63.0mV 108.0mV
Voltage setting dial 10 Rotary
Output current 0 to 1A 0 to 600mA 0 to 400mA 0 to 250mA 0 to 420mA 0 to 200mA 0 to 100mA
Resolution (logical value) 180uA 108uA 72uA 45uA 76uA 36uA 18uA
Current setting dial 10 Rotary
CONSTANT VOLTAGE CHARACTERISTICS CV
Input regulation
For ±10% variance of source voltage *1
5mV 7mV 8mV 15mV 20mV 30mV
Load regulation
For 0V to 100% variance of output current *1
5mV 7mV 8mV 15mV 20mV 30mV
Ripple and noise
rms10Hz to 1MHz *2
1mV 1.2mV 1.6mV 2.5mV 3.5mV 5mV
Transient response
typcurrent 10% to 100% *3
50us typ
Temperature coefficient
typ 100ppm/°C typ
Rise time
Full load/No load typ
100ms/
100ms
150ms/150ms 190ms/190ms
200ms/
200ms
330ms/ 330ms
Fall time
Full load/No load typ
50ms/1s 50ms/1.5s
Remote control
External voltage/
output voltage ratio
Approx.
10V/80V
Approx.
10V/120V
Approx.
10V/160V
Approx. 10V/250V
Approx.
10V/350V
Approx.
10V/600V
Remote control
External resistance/
output voltage ratio
Approx.
10kΩ/80V
Approx.
10kΩ/120V
Approx.
10kΩ/160V
Approx. 10kΩ/250V
Approx.
10kΩ/350V
Approx.
10kΩ/600V
4
Item PA10-5B PA18-1.2B PA18-2B PA18-3B PA18-5B PA36-1.2B PA36-2B PA36-3B
CONSTANT-CURRENT CHARACTERISTICS (CC)
Input regulation
For ±10% source voltage fluctuation *1
2mA
Load regulation
For 0V to 100% variance of output voltage *1
5mA 5mA 5mA 5mA 5mA
Ripple and noise rms (10 Hz to 1 MHz) *2 5mA 1mA 5mA 1mA 2mA
Temperature coefficient
typ 250ppm/°C typ
Remote control
External voltage to output current ratio
Approx.
10 V/5 A
Approx.
10 V/1.2A
Approx.
10 V/2 A
Approx.
10 V/3 A
Approx.
10 V/5 A
Approx.
10 V/1.2A
Approx.
10 V/2 A
Approx.
10 V/3 A
Remote control
External resistance to output current ratio
Approx.
10 kΩ/5 A
Approx.
10k Ω/1.2A
Approx.
10 kΩ/2 A
Approx.
10 kΩ/3 A
Approx.
10 kΩ/5 A
Approx.
10k Ω/1.2A
Approx.
10 kΩ/2 A
Approx.
10 kΩ/3 A
Constant-voltage operation display
Off when output is off CV (green LED) is on.
Constant-current operation display
Off when output is off CC (red LED) is on.
DIDITAL METER DISPLAY
Voltmeter display 3 1/2-digit LEDs, red 19.99 V max., fixed range 19.99V/199.9V max., auto range
Accuracy Output on ±(0.2% rdg + 1 digit), 23 ±5°C, 80%RH or less
Ammeter display 3-digit LEDs, red 9.99 A max., fixed range
Accuracy Output on *4 ±(1.0% rdg + 2 digits), 23 ±5°C, 80%RH or less
Sampling rate Approx. 2.5 times/sec. or more
5
Item PA80-1B PA120-0.6B PA160-0.4B PA250-0.25B PA250-0.42B PA350-0.2B PA600-0.1B
CONSTANT CURRENT CHARACTERISTICS CC
Input regulation
For ±10% source voltage fluctuation *1
2mA 1mA 0.5mA 1mA 0.5mA
Load regulation
For 0V to 100% variance of output voltage *1
5mA 5mA 5mA 5mA 5mA 2.5mA
Ripple and noise
rms10Hz to 1MHz
*2
2mA 1mA
Temperature coefficient
typ 250ppm/°C typ
200ppm/°C typ
250ppm/°C
typ
200ppm/°C typ
Remote control
External voltage to output current ratio
Approx.10V/1A
Approx.
10V/0.6A
Approx.
10V/0.4A
Approx.
10V/0.25A
Approx.
10V/0.42A
Approx.
10V/0.2A
Approx.
10V/0.1A
Remote control
External resistance to output current ratio
Approx.
10kΩ/1A
Approx.
10kΩ/0.6A
Approx.
10kΩ/0.4A
Approx.
10kΩ/0.25A
Approx.
10kΩ/0.42A
Approx.
10kΩ/0.2A
Approx.
10kΩ/0.1A
Constant-voltage operation display
Off when output is off CV (green LED) is on.
Constant-current operation display
Off when output is off CC (red LED) is on.
DIDITAL METER DISPLAY
Voltmeter display 3 1/2-digit LEDs, red
199.9/999 V
max.,auto range
199.9 V max., fixed range
199.9/999 V max., auto range
Accuracy Output on
±(0.2% rdg + 1 digit), 23 ±5°C, 80%RH or less
±(0.2% rdg + 2 digit), 23 ±5°C, 80%RH or less
Ammeter display 3-digit LEDs, red
9.99A max., fixed range
999mA max., fixed range
Accuracy Output on *4
±(1.0% rdg + 2 digit), 23 ±5°C, 80%RH or less
±(1.0% rdg + 3 digit), 23 ±5°C, 80%RH or less
Sampling rate Approx. 2.5 times/sec. or more
6
Item PA10-5B PA18-1.2B PA18-2B PA18-3B PA18-5B PA36-1.2B PA36-2B PA36-3B
FUNCTIONS
OVP ALARM LED goes on Approx. 5 to 105%
OHP ALARM LED goes on
Output goes off when internal heat sink temperature reaches 105 ±5°C.
(Only PA18-5B,PA36-3B are 110°C)
Output switch Remote on/off control
Output may be turned on or off with remote control switch on rear panel.
(Front/rear control is selected with switch on front panel.)
V/I check switch Indicator indicates constant-voltage or constant-current set value when switch is turned on.
Remote sensing Enabled with (+S) and (-S) terminals on front panel. May correct up to 0.5 V, one way. *5
Voltage monitor
Output voltage to monitor voltage ratio
Output voltage 0 to rated voltage/approx. 0 to 10 V output (Connector on rear panel)
Current monitor
Output current to monitor voltage ratio
Output current 0 to rated current/approx. 0 to 10 V output (Connector on rear panel)
Status signal CV Open collector output, Low in CV mode
CC Open collector output, Low in CC mode
ALARM Open collector output, Low in alarm mode
Parallel operation
Master/slave system
Capable of one-control parallel operation.
(Current error: ±20%, up to 3 units. One-control is applicable to same models only.)
7
Item PA80-1B PA120-0.6B PA160-0.4B PA250-0.25B PA250-0.42B PA350-0.2B PA600-0.1B
FUNCTIONS
OVP ALARM LED goes on Approx. 5 to 105%
OHP ALARM LED goes on
Output goes off when internal heat sink temperature reaches 105 ±5°C.
(Only PA250-0.42B is 110°C)
Output switch Remote on/off control
Output may be turned on or off with remote control switch on rear panel.
(Front/rear control is selected with switch on front panel.)
V/I check switch Indicator indicates constant-voltage or constant-current set value when switch is turned on.
Voltage monitor
Output voltage to monitor voltage ratio
Output voltage 0 to rated voltage/approx. 0 to 10 V output (Connector on rear panel)
Current monitor
Output current to monitor voltage ratio
Output current 0 to rated current/approx. 0 to 10 V output (Connector on rear panel)
CV Open collector output, Low in CV mode
CC Open collector output, Low in CC mode
Status signal
ALARM Open collector output, Low in ALARM mode
Parallel operation Master/slave system
Capable of one-control parallel operation.
(Current error: ±20%, up to 3 units. One-control is applicable to same models only.)
Loading...