EN 6 I Active low enable
GND 8 Ground
MR1 4 I Manual reset input 1, active low, pulled up internally
MR2 5 I Manual reset input 2, active low, pulled up internally
NC 1, 11, 20 No connection
PG1 16 O Open drain output, low when V
OUT1
voltage is less than 95% of the nominal regulated voltage
RESET 15 O Open drain output, SVS (power on reset) signal, active low
SEQ 7 I Power up sequence control: SEQ=High, V
OUT2
powers up first; SEQ=Low, V
OUT1
powers up first, SEQ
terminal pulled up internally .
V
IN1
2, 3 I Input voltage of regulator 1
V
IN2
9, 10 I Input voltage of regulator 2
V
OUT1
18, 19 O Output voltage of regulator 1
V
OUT2
12, 13 O Output voltage of regulator 2
V
SENSE2
/FB2 14 I Regulator 2 output voltage sense/ regulator 2 feedback for adjustable
V
SENSE1
/FB1 17 I Regulator 1 output voltage sense/ regulator 1 feedback for adjustable
absolute maximum ratings over operating junction temperature (unless otherwise noted)
†
Input voltage range‡:V
IN1
–0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
IN2
–0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at EN –0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range (V
OUT1
, V
SENSE1
) 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range (V
OUT2
, V
SENSE2
) 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum RESET, PG1 voltage 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum MR1, MR2, and SEQ voltage V
IN1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak output current Internally limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, T
J
–40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESD rating, HBM 2 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
‡
All voltages are tied to network ground.
DISSIPATION RATING TABLE
PACKAGE
AIR FLOW
(CFM)
TA ≤ 25°C