Texas Instruments TPS2047DR, TPS2047D, TPS2057DR, TPS2057D Datasheet

TPS2047, TPS2057
TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
features
D
D
250 mA Continuous Current per Channel
D
Independent Short-Circuit and Thermal Protection With Overcurrent Logic Output
D
Operating Range . . . 2.7-V to 5.5-V
D
Logic-Level Enable Input
D
2.5-ms Typical Rise Time
D
Undervoltage Lockout
D
20 µA Maximum Standby Supply Current
D
Bidirectional Switch
D
Available in 16-pin SOIC Package
D
Ambient Temperature Range, –40°C to 85°C
D
2-kV Human-Body-Model, 200-V Machine-Model ESD Protection
typical applications
D
Notebook, Desktop and Palmtop PCs
D
Monitors, Keyboards, Scanners, and Printers
D
Digital Cameras, Phones, and PBXs
D
Hot-Insertion Applications
description
The TPS2047 and TPS2057 triple power-distribution switches are intended for applications where heavy capacitive loads and short circuits are likely. These devices incorporate in single packages three 135-m N-channel MOSFET high-side power switches for power-distribution systems that require multiple power switches. Each switch is controlled by a logic enable compatible with 5-V and 3-V logic. Gate drive is provided by an internal charge pump that controls the power-switch rise times and fall times to minimize current surges during switching. The charge pump, requiring no external components, allows operation from supplies as low as 2.7 V.
When the output load exceeds the current-limit threshold or a short is present, the TPS2047 and TPS2057 limit the output current to a safe level by switching into a constant-current mode, pulling the overcurrent (OCx
) logic output low. When continuous heavy overloads and short circuits increase the power dissipation in the switch causing the junction temperature to rise, a thermal protection circuit shuts off the switch in overcurrent to prevent damage. Recovery from a thermal shutdown is automatic once the device has cooled sufficiently. Internal circuitry ensures the switch remains off until valid input voltage is present.
The TPS2047 and TPS2057 are designed to limit at 0.44-A load. These power-distribution switches are available in 16-pin small-outline integrated circuit (SOIC) packages and operate over an ambient temperature range of –40°C to 85°C.
AVAILABLE OPTIONS
RECOMMENDED MAXIMUM TYPICAL SHORT-CIRCUIT
PACKAGED DEVICES
T
A
ENABLE
CONTINUOUS LOAD CURRENT
(A)
CURRENT LIMIT AT 25°C
(A)
SOIC
(D)
–40°C to 85°C Active low 0.25 0.44 TPS2047D –40°C to 85°C Active high 0.25 0.44 TPS2057D
The D package is available taped and reeled. Add an R suffix to device type (e.g., TPS2047DR)
Copyright 1999, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10
9
GND1
IN1 EN1 EN2
GND2
IN2 EN3
NC
OC1 OUT1 OUT2 OC2 OC3 OUT3 NC NC
TPS2047
D PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10
9
GND1
IN1 EN1 EN2
GND2
IN2 EN3
NC
OC1 OUT1 OUT2 OC2 OC3 OUT3 NC NC
TPS2057
D PACKAGE
(TOP VIEW)
NC – No internal connection
TPS2047, TPS2057 TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TPS2047 functional block diagram
Thermal
Sense
Driver
Current
Limit
Charge
Pump
UVLO
CS
Driver
Current
Limit
CS
Thermal
Sense
Charge
Pump
Power Switch
GND1
EN1
IN1
EN2
OC1
OUT1
OUT2
OC2
Current sense
Thermal
Sense
Driver
Current
Limit
Charge
Pump
UVLO
CS
Power Switch
GND2
EN3
IN2
OC3
OUT3
TPS2047, TPS2057
TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Terminal Functions
TERMINAL
NO.
I/O DESCRIPTION
NAME
TPS2047 TPS2057
EN1 3 I Enable input. Logic low turns on power switch, IN1-OUT1. EN2 4 I Enable input. Logic low turns on power switch, IN1-OUT2. EN3 7 I Enable input. Logic low turns on power switch, IN2-OUT3. EN1 3 I Enable input. Logic high turns on power switch, IN1-OUT1. EN2 4 I Enable input. Logic high turns on power switch, IN1-OUT2. EN3 7 I Enable input. Logic high turns on power switch, IN2-OUT3. GND1 1 1 Ground GND2 5 5 Ground IN1 2 2 I Input voltage IN2 6 6 I Input voltage NC 8, 9, 10 8, 9, 10 No connection OC1 16 16 O Overcurrent. Logic output active low, IN1-OUT1 OC2 13 13 O Overcurrent. Logic output active low, IN1-OUT2 OC3 12 12 O Overcurrent. Logic output active low, IN2-OUT3 OUT1 15 15 O Power-switch output, IN1-OUT1 OUT2 14 14 O Power-switch output, IN1-OUT2 OUT3 11 11 O Power-switch output, IN2-OUT3
TPS2047, TPS2057 TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
detailed description
power switch
The power switch is an N-channel MOSFET with a maximum on-state resistance of 135 m (V
I(INx)
= 5 V). Configured as a high-side switch, the power switch prevents current flow from OUTx to INx and INx to OUTx when disabled. The power switch can supply a minimum of 250 mA per switch.
charge pump
An internal charge pump supplies power to the driver circuit and provides the necessary voltage to pull the gate of the MOSFET above the source. The charge pump operates from input voltages as low as 2.7 V and requires very little supply current.
driver
The driver controls the gate voltage of the power switch. T o limit large current surges and reduce the associated electromagnetic interference (EMI) produced, the driver incorporates circuitry that controls the rise times and fall times of the output voltage. The rise and fall times are typically in the 2-ms to 4-ms range.
enable (ENx or ENx)
The logic enable disables the power switch and the bias for the charge pump, driver, and other circuitry to reduce the supply current to less than 20 µA when a logic high is present on ENx (TPS2047) or a logic low is present on ENx (TPS2057). A logic zero input on ENx or logic high on ENx restores bias to the drive and control circuits and turns the power on. The enable input is compatible with both TTL and CMOS logic levels.
overcurrent (OCx)
The OCx
open drain output is asserted (active low) when an overcurrent or over temperature condition is
encountered. The output will remain asserted until the overcurrent or over temperature condition is removed.
current sense
A sense FET monitors the current supplied to the load. The sense FET measures current more efficiently than conventional resistance methods. When an overload or short circuit is encountered, the current-sense circuitry sends a control signal to the driver. The driver in turn reduces the gate voltage and drives the power FET into its saturation region, which switches the output into a constant current mode and holds the current constant while varying the voltage on the load.
thermal sense
The TPS2047 and TPS2057 implement a dual-threshold thermal trip to allow fully independent operation of the power distribution switches. In an overcurrent or short-circuit condition the junction temperature rises. When the die temperature rises to approximately 140°C, the internal thermal sense circuitry checks to determine which power switch is in an overcurrent condition and turns off that switch, thus, isolating the fault without interrupting operation of the adjacent power switches. Hysteresis is built into the thermal sense, and after the device has cooled approximately 20 degrees, the switch turns back on. The switch continues to cycle off and on until the fault is removed. The (OCx
) open-drain output is asserted (active low) when overtemperature or overcurrent
occurs.
undervoltage lockout
A voltage sense circuit monitors the input voltage. When the input voltage is below approximately 2 V , a control signal turns off the power switch.
TPS2047, TPS2057
TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Input voltage range, V
I(INx)
(see Note1) –0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O(OUTx)
(see Note1) –0.3 V to V
I(INx)
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I(ENx)
or V
I(ENx)
–0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O(OUTx)
Internally limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, T
J
–40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge (ESD) protection: Human body model MIL-STD-883C 2 kV. . . . . . . . . . . . . . . . . . . . .
Machine model 0.2 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
DISSIPATION RATING TABLE
PACKAGE
TA 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
D 725 mW 5.8 mW/°C 464 mW 377 mW
recommended operating conditions
TPS2047 TPS2057
MIN MAX MIN MAX
UNIT
Input voltage, V
I(INx)
2.7 5.5 2.7 5.5 V
Input voltage, V
I(ENx)
or V
I(ENx)
0 5.5 0 5.5 V
Continuous output current, I
O(OUTx)
0 250 0 250 mA
Operating virtual junction temperature, T
J
–40 125 –40 125 °C
TPS2047, TPS2057 TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating junction temperature range, V
I(INx)
= 5.5 V ,
I
O
= rated current, V
I(ENx)
= 0 V, V
I(ENx)
= Hi (unless otherwise noted)
power switch
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
V
I(INx)
= 5 V,
IO = 0.25 A
TJ = 25°C,
80 95 80 95
Static drain-source on-state resistance, 5-V operation
V
I(INx)
= 5 V,
IO = 0.25 A
TJ = 85°C,
90 120 90 120
V
I(INx)
= 5 V,
IO = 0.25 A
TJ = 125°C,
100 135 100 135
m
r
DS(on)
V
I(INx)
= 3.3 V,
IO = 0.25 A
TJ = 25°C,
85 105 85 105
Static drain-source on-state resistance, 3.3-V operation
V
I(INx)
= 3.3 V,
IO = 0.25 A
TJ = 85°C,
100 135 100 135
V
I(INx)
= 3.3 V,
IO = 0.25 A
TJ = 125°C,
115 150 115 150
p
V
I(INx)
= 5.5 V,
CL = 1 µF,
TJ = 25°C, RL = 20
2.5 2.5
trRise time, output
V
I(INx)
= 2.7 V,
CL = 1 µF,
TJ = 25°C, RL = 20
3 3
ms
p
V
I(INx)
= 5.5 V,
CL = 1 µF,
TJ = 25°C, RL = 20
4.4 4.4
tfFall time, output
V
I(INx)
= 2.7 V,
CL = 1 µF,
TJ = 25°C, RL = 20
2.5 2.5
ms
Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately.
enable input ENx or ENx
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
V
IH
High–level input voltage 2.7 V ≤ V
I(INx)
5.5 V 2 2 V
p
4.5 V ≤ V
I(INx)
5.5 V 0.8 0.8 V
VILLow–level input voltage
2.7 V≤ V
I(INx)
4.5 V 0.4 0.4
p
TPS2047 V
I(ENx
)
= 0 V or V
I(ENx)
= V
I(INx)
–0.5 0.5
IIInput current
TPS2057 V
I(ENx)
= V
I(INx)
or V
I(ENx)
= 0 V –0.5 0.5
µ
A
t
on
Turnon time CL = 100 µF, RL = 20 20 20 ms
t
off
Turnoff time CL = 100 µF, RL = 20 40 40
current limit
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
I
OS
Short-circuit output current
V
I(INx)
= 5 V, OUT connected to GND,
Device enable into short circuit
0.345 0.44 0.525 0.345 0.44 0.525 A
Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately.
TPS2047, TPS2057
TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating junction temperature range, V
I(INx)
= 5.5 V ,
I
O
= rated current, V
I(ENx)
= 0 V, V
I(ENx)
= Hi (unless otherwise noted) (continued)
supply current
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
TJ = 25°C
0.03 2
Supply current, No Load
V
I(ENx)
= V
I(INx)
–40°C ≤ TJ 125°C
TPS2047
20
y,
low-level output on OUTx
TJ = 25°C
0.03 2
µ
A
V
I(ENx)
= 0
V
–40°C TJ 125°C
TPS2057
20
TJ = 25°C
160 200
Supply current,
No Load
V
I(ENx)
= 0
V
–40°C TJ 125°C
TPS2047
200
high-level
output
on OUTx
TJ = 25°C
160 200
µ
A
V
I(ENx)
=
V
I(INx)
–40°C ≤ TJ 125°C
TPS2057
200
Leakage OUTx connected
V
I(ENx)
= V
I(INx)
°
°
TPS2047 200
g
current to ground
V
I(ENx)
= 0 V
40°C ≤ T
J
125°C
TPS2057 200
µ
A
Reverse INx = high
V
I(ENx)
= 0 V
°
TPS2047 0.3
leakage currentgimpedance
V
I(ENx)
= Hi
T
J
=
25°C
TPS2057 0.3
µ
A
undervoltage lockout
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
Low-level input voltage 2 2.5 2 2.5 V Hysteresis TJ = 25°C 100 100 mV
overcurrent OCx
TPS2047 TPS2057
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
Sink current
VO = 5 V 10 10 mA
Output low voltage IO = 5 mA, V
OL(OCx
)
0.5 0.5 V
Off-state current
VO = 5 V, VO = 3.3 V 1 1 µA
Specified by design, not production tested.
TPS2047, TPS2057 TRIPLE CURRENT-LIMITED POWER-DISTRIBUTION SWITCHES
SLVS194 – APRIL 1999
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
RL CL
OUTx
t
r
t
f
90%
90%
10%
10%
50%
50%
90%
10%
V
O(OUTx)
V
I(ENx)
V
O(OUTx)
VOLTAGE WA VEFORMS
TEST CIRCUIT
t
on
t
off
50%
50%
90%
10%
V
I(ENx)
V
O(OUTx)
t
on
t
off
Figure 1. Test Circuit and Voltage Waveforms
Figure 2. Turnon Delay and Rise Time
with 0.1-µF Load
Figure 3. Turnoff Delay and Fall Time
with 0.1-µF Load
V
O(OUTx)
(2 V/div)
0123456
t – Time – ms
78910
V
I(INx)
= 5 V TA = 25°C CL = 0.1 µF
V
I(ENx)
(5 V/div)
0 1000 2000 3000
t – Time – ms
4000 5000
V
I(INx)
= 5 V TA = 25°C CL = 0.1 µF
V
I(ENx)
(5 V/div)
V
O(OUTx)
(2 V/div)
Loading...