T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty . Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICA TIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERST OOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1999, Texas Instruments Incorporated
About This Manual
Information About Cautions and Warnings
Preface
Read This First
The purpose of this user’s guide is to serve as a reference book for the
TLC5540/TLC5510/TLC5510A/TLV5510/TLV5540 devices. This document
provides information to assist managers and hardware/software engineers in
application development.
How to Use This Manual
This document contains the following chapters:
-
Chapter 1 Overview
-
Chapter 2 Circuit Description
-
Chapter 3 Physical Description
Information About Cautions and Warnings
This book may contain cautions and warnings.
This is an example of a caution statement.
A caution statement describes a situation that could potentially
damage your software or equipment.
This is an example of a warning statement.
A warning statement describes a situation that could potentially
cause harm to you
.
The information in a caution or a warning is provided for your protection.
Please read each caution and warning carefully.
Read This First
iii
Related Documentation From Texas Instruments
Related Documentation From Texas Instruments
The following documents may be ordered by contacting the T exas Instruments
Product Information Center at one of the numbers listed on the next page, or,
they may be downloaded at:
http://www–s.ti.com/sc/docs/psheets/pids2.htm
CE/FCC Warnings
TLC5510/TLC5510A Data Sheet
(literature number SLAS095) contains
electrical specifications, available temperature options, general overview of the device, and application information.
TLC5540 Data Sheet
(literature number SLAS105) contains electrical
specifications, available temperature options, general overview of the
device, and application information.
TLV5510 Data Sheet
(literature number SLAS124) contains electrical
specifications, available temperature options, general overview of the
device, and application information.
TLV5540 Data Sheet
(literature number SLAS192) contains electrical
specifications, available temperature options, general overview of the
device, and application information.
This equipment is intended for use in a laboratory test environment only . It generates, uses, and can radiate radio frequency energy and has not been tested
for compliance with the limits of computing devices pursuant to subpart J of
part 15 of FCC rules.This device has been tested and found to comply with the
limits for a CISPRII Group 1 and the following directives: EMC Directive
89/336/EEC amending directive 92/31/EEC and 93/68/EEC as per
ENV50204:1995, EN55011: 1995 Class A, EN61000–4–4: 1995, and
EN6100–4–3: 1993. Operation of this equipment in other environments may
cause interference with radio communications, in which case the user at his
own expense will be required to take whatever measures may be required to
correct this interference.
The TLC5540/TLC5510/TLC5510A/TLV5540/TLV5510 evaluation module
(EVM) provides a platform for lab prototype evaluation of the Texas Instruments TLC5540/TLC5510/TLC5510A/TLV5540/TLV5510 8-bit, high-speed
analog-to-digital converters.
Since practical operation can be acheived in excess of 40 MHz, the circuit
layout is critical and does not lend itself to classic breadboarding techniques.
In fact, proper operation requires use of surface-mount components.
1-2
Overview
Loading...