Texas Instruments SN74BCT646DW, SN74BCT646DWR, SN74BCT646NT, SNJ54BCT646FK, SNJ54BCT646JT Datasheet

...
SN54BCT646, SN74BCT646
OCTAL BUS TRANSCEIVERS AND REGISTERS
WITH 3-STATE OUTPUTS
SCBS037C – AUGUST 1989 – REVISED NOVEMBER 1993
State-of-the-Art BiCMOS Design
Significantly Reduces I
CCZ
SN54BCT646 . . . JT OR W PACKAGE
SN74BCT646 . . . DW OR NT PACKAGE
(TOP VIEW)
ESD Protection Exceeds 2000 V Per
MIL-STD-883C, Method 3015; Exceeds 200 V Using Machine Model (C = 200 pF, R = 0)
Bus Transceivers/Registers
Independent Registers and Enables for
A and B Buses
Multiplexed Real-Time and Stored Data
Power-Up High-Impedance Mode
Package Options Include Plastic
Small-Outline (DW) Packages, Ceramic Chip Carriers (FK) and Flatpacks (W), and Plastic and Ceramic 300-mil DIPs (JT, NT)
description
These devices consist of bus transceiver circuits, D-type flip-flops, and control circuitry arranged for multiplexed transmission of data directly from the input bus or from the internal registers. Data on the A or B bus is clocked into the registers on the low-to-high transition of the appropriate clock (CLKAB or CLKBA) input. Figure 1 illustrates the four fundamental bus-management functions that can be performed with the ′BCT646.
Output-enable (OE inputs are provided to control the transceiver functions. In the transceiver mode, data present at the high-impedance port may be stored in either register or in both.
The select-control (SAB and SBA) inputs can multiplex stored and real-time (transparent mode) data. The direction control (DIR) determines which bus will receive data when OE (OE high), A data may be stored in one register and/or B data may be stored in the other register.
) and direction-control (DIR)
CLKAB
SAB
GND
SN54BCT646 . . . FK PACKAGE
A1 A2 A3
NC
A4 A5 A6
NC – No internal connection
1 2
DIR
3
A1
4
A2
5
A3
6
A4
7
A5
8
A6
9
A7
10
A8
11 12
(TOP VIEW)
DIR
SAB
CLKAB
432128
5 6 7 8 9 10 11
12 13 14 15 16
A8
A7
GND
24 23 22 21 20 19 18 17 16 15 14 13
NC
NC
is low. In the isolation mode
CC
V
27 26
17 18
B8
V
CC
CLKBA SBA OE B1 B2 B3 B4 B5 B6 B7 B8
CLKBA
SBA
25 24 23 22 21 20 19
B7
B6
When an output function is disabled, the input function is still enabled and may be used to store and transmit data. Only one of the two buses, A or B, may be driven at a time.
The SN54BCT646 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74BCT646 is characterized for operation from 0°C to 70°C.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright 1993, Texas Instruments Incorporated
2–1
SN54BCT646, SN74BCT646 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SCBS037C – AUGUST 1989 – REVISED NOVEMBER 1993
21 OE
L
BUS A
3
DIR
L
BUS A
1
CLKAB
REAL-TIME TRANSFER
BUS B TO BUS A
CLKBA
X
23
BUS B
22
2
SAB
X
SBA
X
L
BUS B
21 OE
BUS A
3
DIR
L
H
BUS A
1
CLKAB
X
REAL-TIME TRANSFER
BUS A TO BUS B
23
CLKBA
X
2
SAB
L
BUS B
22
SBA
X
BUS B
21
X X H
3
DIR
X X X
1
CLKAB23CLKBA
XX
STORAGE FROM
A, B, OR A AND B
2
22
SAB
X
↑ ↑
SBA
X
X
X X X
Figure 1. Bus-Management Functions
Pin numbers shown are for the DW, JT, NT, and W packages.
2–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
21
OEOE
L LH L XHX
3
DIR
L
1
CLKAB
X
TRANSFER STORED DA TA
TO A AND/OR B
23
CLKBA
L
2
SAB
X
22
SBA
H
SN54BCT646, SN74BCT646
OPERATION OR FUNCTION
OCTAL BUS TRANSCEIVERS AND REGISTERS
WITH 3-STATE OUTPUTS
SCBS037C – AUGUST 1989 – REVISED NOVEMBER 1993
FUNCTION TABLE
INPUTS
OE DIR CLKAB CLKBA SAB SBA A1 THRU A8 B1 THRU B8
X X X X X Input Unspecified X XX X X Unspecified H X X X Input Input Store A and B data H X H or L H or L X X Input disabled Input disabled Isolation, hold storage L L X X X L Output Input Real-time B data to A bus L L X H or L X H Output Input Stored B data to A bus L H X X L X Input Output Real-time A data to B bus L H H or L X H X Input Output Stored A data to B bus
The data output functions may be enabled or disabled by various signals at the OE and DIR inputs. Data input functions are always enabled; i.e., data at the bus pins will be stored on every low-to-high transition of the clock inputs.
DATA I/O
Input Store B, A unspecified
Store A, B unspecified
† †
logic symbol
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the DW, JT, NT, and W packages.
OE
DIR
CLKBA
SBA
CLKAB
SAB
A1
A2 A3 A4 A5 A6 A7 A8
21 3
23 22
1
2
4
5 6
7 8 9 10 11
G3 3 EN1 [BA]
3 EN2 [AB]
C4
G5
C6
G7
5
1
1
5
7
6D 1
7
1
4D
1
2
20
19 18 17 16 15 14 13
B1
B2 B3 B4 B5 B6 B7 B8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2–3