Inputs Are TTL-Voltage Compatible
D
(Enhanced-Performance Implanted
CMOS) 1-µm Process
D
Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), and Thin Shrink Small-Outline (PW) Packages, Ceramic Chip Carriers (FK) and Flatpacks (W), and Standard Plastic (N) and Ceramic (J) DIPS
description
The ’ACT08 are quadruple 2-input positive-AND gates. These devices perform the Boolean functions Y = A B or Y = A + B in positive logic.
The SN54ACT08 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74ACT08 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
(each gate)
INPUTS
A B
H H H
L XL
X L L
OUTPUT
Y
SN54ACT08 ... J OR W PACKAGE
SN74ACT08 ... D, DB, N, OR PW PACKAGE
SN54ACT08 .. . FK PACKAGE
1Y
NC
2A
NC
2B
NC – No internal connection
(TOP VIEW)
1A 1B 1Y 2A 2B 2Y
GND
(TOP VIEW)
1B1ANC
3 2 1 20 19
4 5 6 7 8
910111213
2Y
1 2 3 4 5 6 7
GND
NC
14 13 12 11 10
9 8
V
3Y
CC
4B
18 17 16 15 14
3A
V 4B 4A 4Y 3B 3A 3Y
CC
4A NC 4Y NC 3B
logic symbol
1
1A
2
1B
4
2A
5
2B
9
3A
10
3B
12
4A
13
4B
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, DB, J, N, PW, and W packages.
EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
&
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
3
1Y
6
2Y
8
3Y
11
4Y
logic diagram, each gate (positive logic)
A
Y
B
Copyright 1996, Texas Instruments Incorporated
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1
SN54ACT08, SN74ACT08
UNIT
QUADRUPLE 2-INPUT POSITIVE-AND GATES
SCAS535A – SEPTEMBER 1995 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
Input voltage range, VI (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, IIK (VI < 0 or VI > VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (VO < 0 or VO > VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
Continuous current through VCC or GND ±200 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum power dissipation at TA = 55°C (in still air) (see Note 2):D package 1.25 W. . . . . . . . . . . . . . . . . .
Storage temperature range, T
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils, except for the N package, which has a trace length of zero.
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
(VO = 0 to VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
O
DB package 0.5 W. . . . . . . . . . . . . . . . . .
N package 1.1 W. . . . . . . . . . . . . . . . . . .
PW package 0.5 W. . . . . . . . . . . . . . . . . .
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
recommended operating conditions (see Note 3)
SN54ACT08 SN74ACT08
MIN MAX MIN MAX
V
CC
V
IH
V
IL
V
I
V
O
I
OH
I
OL
t/∆v Input transition rise or fall rate 0 8 0 8 ns/V T
A
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
Supply voltage 4.5 5.5 4.5 5.5 V High-level input voltage 2 2 V Low-level input voltage 0.8 0.8 V Input voltage 0 V Output voltage 0 V High-level output current –24 –24 mA Low-level output current 24 24 mA
Operating free-air temperature –55 125 –40 85 °C
CC CC
0 V 0 V
CC CC
V V
2