Texas Instruments SN74F260D, SN74F260DR, SN74F260N Datasheet

SN74F260
DUAL 5-INPUT POSITIVE-NOR GATE
SDFS012A – D3214, JANUARY 1989 – REVISED OCT OBER 1993
Copyright 1993, Texas Instruments Incorporated
2–1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Package Options Include Plastic
Small-Outline Packages and Standard Plastic 300-mil DIPs
description
The SN74F260 contains two independent 5-input positive-NOR gates. It performs the Boolean functions Y = A + B + C + D + E
in positive logic.
The SN74F260 is characterized for operation from 0°C to 70°C.
logic symbol
logic diagram, each gate (positive logic)
1
1A
2
1B
1Y
5
3
1C
12
1D
2Y
6
8
2B
9
2C
A B
Y
1
C D E
10
2D
11
2E
13
1E
4
2A
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1) –1.2 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current range –30 mA to 5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state –0.5 V to V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state 40 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
D OR N PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7
14 13 12 11 10
9 8
1A 1B 1C 2A 1Y 2Y
GND
V
CC
1E 1D 2E 2D 2C 2B
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN74F260 DUAL 5-INPUT POSITIVE-NOR GATE
SDFS012A – D3214, JANUAR Y 1989 – REVISED OCT OBER 1993
2–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
IK
Input clamp current –18 mA
I
OH
High-level output current –1 mA
I
OL
Low-level output current 20 mA
T
A
Operating free-air temperature 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP†MAX UNIT
V
IK
VCC = 4.5 V, II = –18 mA –1.2 V VCC = 4.5 V, IOH = – 1 mA 2.5 3.4
V
OH
VCC = 4.75 V , IOH = – 1 mA 2.7
V
V
OL
VCC = 4.5 V, IOL = 20 mA 0.3 0.5 V
I
I
VCC = 5.5 V, VI = 7 V 0.1 mA
I
IH
VCC = 5.5 V, VI = 2.7 V 20 µA
I
IL
VCC = 5.5 V, VI = 0.5 V – 0.6 mA
I
OS
VCC = 5.5 V, VO = 0 –60 –150 mA
I
CCH
VCC = 5.5 V, VI = 0 4.6 6.5 mA
I
CCL
VCC = 5.5 V, VI = 4.5 V 7.3 9.5 mA
All typical values are at VCC = 5 V, TA = 25°C.
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
switching characteristics (see Note 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 5 V, CL = 50 pF, RL = 500 , TA = 25°C
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500, TA = MIN to MAX
§
UNIT
MIN TYP MAX MIN MAX
t
PLH
1.7 4 5.5 1.2 6.5
t
PHL
A, B, C, D, E
Y
1 2.5 4 1 4.5
ns
§
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
NOTE 2: Load circuits and waveforms are shown in Section 1.