SN74F125
QUADRUPLE BUS BUFFER GATE
WITH 3-STATE OUTPUTS
SDFS016A – D3211, JANUARY 1989 – REVISED OCTOBER 1993
• 3-State Outputs Drive Bus Lines or Buffer
Memory Address Registers
• Package Options Include Plastic
Small-Outline Packages and Standard
Plastic 300-mil DIPs
description
The SN74F125 features independent line drivers
with 3-state outputs. Each output is disabled when
the associated output enable (OE
The SN74F125 is characterized for operation from
0°C to 70°C.
logic symbol
†
) input is high.
FUNCTION TABLE
(each buffer)
INPUTS
OE A
L H H
L LL
HXZ
OUTPUT
Y
logic diagram (positive logic)
D OR N PACKAGE
(TOP VIEW)
1OE
2OE
GND
1A
1Y
2A
2Y
1
2
3
4
5
6
7
14
13
12
11
10
V
CC
4OE
4A
4Y
3OE
9
3A
8
3Y
1
1OE
2
1A
4
2OE
5
2A
10
3OE
9
3A
13
4OE
12
4A
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
EN
1
3
6
8
11
1Y
2Y
3Y
4Y
1OE
2OE
3OE
4OE
1
23
1A 1Y
4
56
2A 2Y
10
98
3A 3Y
13
12 11
4A 4Y
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Copyright 1993, Texas Instruments Incorporated
2–1

SN74F125
QUADRUPLE BUS BUFFER GATE
WITH 3-STATE OUTPUTS
SDFS016A – D3211, JANUARY 1989 – REVISED OCTOBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
Input voltage range, V
Input current range –30 mA to 5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the disabled or power-off state –0.5 V to 5.5 V. . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state –0.5 V to V
Current into any output in the low state 128 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
(see Note 1) –1.2 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions
MIN NOM MAX UNIT
V
V
V
I
I
I
T
CC
IH
IL
IK
OH
OL
A
Supply voltage 4.5 5 5.5 V
High-level input voltage 2 V
Low-level input voltage 0.8 V
Input clamp current –18 mA
High-level output current –15 mA
Low-level output current 64 mA
Operating free-air temperature 0 70 °C
†
CC
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP‡MAX UNIT
V
IK
V
OH
V
OL
I
I
I
IH
I
IL
I
OZH
I
OZL
§
I
OS
I
CCH
I
CCL
I
‡
All typical values are at VCC = 5 V, TA = 25°C.
§
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
CCZ
VCC = 4.5 V, II = –18 mA –1.2 V
= 4.5
CC
VCC = 4.75 V, IOH = – 3 mA 2.7
VCC = 4.5 V, IOL = 64 mA 0.4 0.55 V
VCC = 0, VI = 7 V 0.1 mA
VCC = 5.5 V, VI = 2.7 V 20 µA
VCC = 5.5 V, VI = 0.5 V –20 µA
VCC = 5.5 V, VO = 2.7 V 50 µA
VCC = 5.5 V, VO = 0.5 V –50 µA
VCC = 5.5 V, VO = 0 –100 –225 mA
VCC = 5.5 V, Outputs open 17 24 mA
VCC = 5.5 V, Outputs open 28 40 mA
VCC = 5.5 V, Outputs open 25 35 mA
IOH = – 3 mA 2.4 3.3
IOH = – 15 mA 2 3.1
V
2–2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265

QUADRUPLE BUS BUFFER GATE
WITH 3-STATE OUTPUTS
SDFS016A – D3211, JANUARY 1989 – REVISED OCTOBER 1993
switching characteristics (see Note 2)
VCC = 5 V,
PARAMETER
t
PLH
t
PHL
t
PZH
t
PZL
t
PHZ
t
†
NOTE 2: Load circuits and waveforms are shown in Section 1.
PLZ
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
FROM
(INPUT)
TO
(OUTPUT)
CL = 50 pF,
RL = 500 Ω,
TA = 25°C
MIN TYP MAX MIN MAX
1.2 3.6 6 1.2 6.5
2.2 5.1 7.5 2.2 8
2.7 5.1 7.5 2.7 8.5
3.2 5.6 8 3.2 9
1 3.1 5 1 6
1 3.1 5.5 1 6
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX
SN74F125
UNIT
†
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
2–3

SN74F125
QUADRUPLE BUS BUFFER GATE
WITH 3-STATE OUTPUTS
SDFS016A – D3211, JANUARY 1989 – REVISED OCTOBER 1993
2–4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265

IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty . Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICA TIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERST OOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated