Texas Instruments SN74F112D, SN74F112DR, SN74F112N Datasheet

SN74F112
DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP
WITH CLEAR AND PRESET
SDFS048A – D2932, MARCH 1987 – REVISED OCTOBER 1993
Copyright 1993, Texas Instruments Incorporated
2–1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Package Options Include Plastic
description
The SN74F112 contains two independent J-K negative-edge-triggered flip-flops. A low level at the preset (PRE
) or clear (CLR) inputs sets or resets the outputs regardless of the levels of the other inputs. When PRE
and CLR are inactive (high), data at the J and K inputs meeting the setup time requirements is transferred to the outputs on the negative-going edge of the clock pulse. Clock triggering occurs at a voltage level and is not directly related to the rise time of the clock pulse. Following the hold-time interval, data at the J and K inputs may be changed without affecting the levels at the outputs. The SN74F1 12 can perform as a toggle flip-flop by tying J and K high.
The SN74F1 12 is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS
OUTPUTS
PRE CLR CLK J K Q Q
L H X X X H L H LXXXLH LLXXXH
H
HHLLQ
0
Q
0
HH↓HLHL HHLHLH HHH H Toggle H H H X X Q
0
Q
0
The output levels in this configuration are not guaranteed to meet the minimum levels for VOH. Furthermore, this configuration is nonstable; that is, it will not persist when either PRE
or CLR returns to its inactive (high) level.
D OR N PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10
9
1CLK
1K
1J
1PRE
1Q 1Q 2Q
GND
V
CC
1CLR 2CLR 2CLK 2K 2J 2PRE 2Q
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN74F112 DUAL NEGATIVE-EDGE-TRIGGERED J-K FLIP-FLOP WITH CLEAR AND PRESET
SDFS048A – D2932, MARCH 1987 – REVISED OCT OBER 1993
2–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbol
S
4
1J
3
1J
1K
2
1K
R
15
1Q
5
6
C1
1PRE
1CLR
1Q
1
1CLK
10 11
2J
12
2K
14
2Q
9
7
2PRE
2CLR
2Q
13
2CLK
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram, each flip-flop (positive logic)
PRE
CLK
K
Q Q
CLR
J
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1) –1.2 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current range –30 mA to 5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state –0.5 V to V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state 40 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
Loading...