Texas Instruments SN74AS230ADW, SN74AS230ADWR, SN74AS230AN Datasheet

SN74AS230A
OCTAL BUFFER/DRIVER
WITH 3-STATE OUTPUTS
SDAS213B – DECEMBER 1982 – REVISED DECEMBER 1994
Copyright 1994, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
True and Complementary Outputs
Memory Address Registers
High Capacitive-Drive Capability
Current-Sinking Capability Up to 64 mA
Package Options Include Plastic
Small-Outline (DW) Packages and Standard Plastic (N) 300-mil DIPs
description
This octal buffer/driver is designed specifically to improve the performance of 3-state memory address drivers, clock drivers, and bus-oriented receivers and transmitters. When used together, multiples of this device provide the choice of selected combinations of inverting and noninverting outputs, symmetrical active-low output-enable (OE
) inputs, and complementary OE and OE inputs.
The SN74AS230A is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
(each buffer)
INPUTS
OUTPUT
OE A
Y
L H L L LH
HXZ
logic symbol
2
1A1
4
1A2
6
1A3
8
1A4
EN
1
1Y1
18
1Y2
16
1Y3
14
1Y4
12
11
2A1
13
2A2
15
2A3
17
2A4
EN
19
2Y1
9
2Y2
7
2Y3
5
2Y4
3
1OE
2OE
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
1OE
1A1 2Y4 1A2 2Y3 1A3 2Y2 1A4 2Y1
GND
V
CC
2OE 1Y1 2A4 1Y2 2A3 1Y3 2A2 1Y4 2A1
DW OR N PACKAGE
(TOP VIEW)
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN74AS230A OCTAL BUFFER/DRIVER WITH 3-STATE OUTPUTS
SDAS213B – DECEMBER 1982 – REVISED DECEMBER 1994
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic diagram (positive logic)
1
2
4
6
8
19
11
13
15
17
3
5
7
9
12
14
16
18
1A1
1A2
1A3
1A4
1Y1
2A1
2A2
2A3
2A4
2Y1
1Y2
1Y3
1Y4
2Y2
2Y3
2Y4
2OE
1OE
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to a disabled 3-state output 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current –15 mA
I
OL
Low-level output current 64 mA
T
A
Operating free-air temperature 0 70 °C
Loading...