Texas Instruments SN54AS1004AJ, SN74AS1004AD, SN74AS1004ADR, SN74AS1004AN, SN74AS1004AN3 Datasheet

SN54AS1004A, SN74ALS1004, SN74AS1004A
HEX INVERTING DRIVERS
SDAS074B – APRIL 1982 – REVISED JANUARY 1995
′AS1004A Offer High Capacitive-Drive
Driver Version of ′ALS04B and ′AS04
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs
description
These devices contain six independent inverting drivers. They perform the Boolean function Y = A
The SN54AS1004A is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74ALS1004 and SN74AS1004A are characterized for operation from 0°C to 70°C.
FUNCTION TABLE (each inverter)
INPUT
OUTPUT
A
H L
L H
Y
SN74ALS1004, SN74AS1004A ...D OR N PACKAGE
SN54AS1004A ...J PACKAGE
(TOP VIEW)
1A 1Y 2A 2Y 3A 3Y
GND
1 2 3 4 5 6 7
14 13 12 11 10
V
CC
6A 6Y 5A 5Y 4A
9
4Y
8
.
SN54AS1004A . . . FK PACKAGE
2A
NC
2Y
NC
3A
NC – No internal connection
(TOP VIEW)
1Y1ANC
3 2 1 20 19
4 5 6 7 8
9 10 11 12 13
3Y
NC
GND
V
CC
4Y
6A
18 17 16 15 14
4A
6Y NC 5A NC 5Y
logic symbol
1
1A
3
2A
5
3A
9
4A
11
5A
13
6A
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
2 4 6
8 10 12
1Y 2Y 3Y 4Y 5Y 6Y
logic diagram (positive logic)
12
3
2A 2Y
5
3A 3Y
9
4A 4Y
11
5A 5Y
13
6A 6Y
1Y1A
4
6
8
10
12
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright 1995, Texas Instruments Incorporated
1
SN54AS1004A, SN74ALS1004, SN74AS1004A
UNIT
PARAMETER
TEST CONDITIONS
UNIT
V
V
VOLV
V
V
(
)
(
)
(INPUT)
(OUTPUT)
A
Y
ns
HEX INVERTING DRIVERS
SDAS074B – APRIL 1982 – REVISED JANUARY 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V Input voltage, V Operating free-air temperature range, T
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
: SN74ALS1004 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS1004
MIN NOM MAX
V V V I I T
CC IH
IL OH OL
A
Supply voltage 4.5 5 5.5 V High-level input voltage 2 V Low-level input voltage 0.8 V High-level output current –15 mA Low-level output current 24 mA Operating free-air temperature 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN74ALS1004
MIN TYP‡MAX
V
IK
V
OH
I
I
I
IH
I
IL
§
I
O
I
CCH
I
All typical values are at VCC = 5 V, TA = 25°C.
§
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
CCL
VCC = 4.5 V, II = –18 mA –1.5 V VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC –2
= 4.5
CC
= 4.5
CC
VCC = 5.5 V, VI = 7 V 0.1 mA VCC = 5.5 V, VI = 2.7 V 20 µA VCC = 5.5 V, VI = 0.4 V –0.1 mA VCC = 5.5 V, VO = 2.25 V –30 –112 mA VCC = 5.5 V, VI = 0 0.84 3 mA VCC = 5.5 V, VI = 4.5 V 7 12 mA
IOH = –3 mA 2.4 3.2 IOH = –15 mA 2 IOL = 12 mA 0.25 0.4 IOL = 24 mA 0.35 0.5
V
switching characteristics (see Figure 1)
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
2
PARAMETER
t
PLH
t
PHL
FROM INPUT
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TO
OUTPUT
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 , TA = MIN to MAX
SN74ALS1004
MIN MAX
1 7 1 6
UNIT
Loading...