SN54AHCU04, SN74AHCU04
HEX INVERTERS
SCLS234H – OCTOBER 1995 – REVISED JANUARY 2000
D
EPIC
(Enhanced-Performance Implanted
CMOS) Process
D
Operating Range 2-V to 5.5-V V
D
Unbuffered Outputs
D
Latch-Up Performance Exceeds 250 mA Per
CC
JESD 17
D
ESD Protection Exceeds 2000 V Per
MIL-STD-883, Method 3015; Exceeds 200 V
Using Machine Model (C = 200 pF, R = 0)
D
Package Options Include Plastic
Small-Outline (D), Shrink Small-Outline
(DB), Thin Very Small-Outline (DGV), Thin
Shrink Small-Outline (PW), and Ceramic
Flat (W) Packages, Ceramic Chip Carriers
(FK), and Standard Plastic (N) and Ceramic
(J) DIPs
description
The ’AHCU04 devices contain six independent
inverters. These devices perform the Boolean
function Y = A. Internal circuitry consists of
single-stage inverters that can be used in analog
applications such as crystal oscillators.
The SN54AHCU04 is characterized for operation
over the full military temperature range of –55°C
to 125°C. The SN74AHCU04 is characterized for
operation from –40°C to 85°C.
SN54AHCU04 ...J OR W PACKAGE
SN74AHCU04 . . . D, DB, DGV, N, OR PW PACKAGE
SN54AHCU04 . . . FK PACKAGE
2A
NC
2Y
NC
3A
NC – No internal connection
(TOP VIEW)
1A
1
1Y
2
2A
3
2Y
4
3A
5
6
3Y
GND
7
(TOP VIEW)
1Y1ANC
3212019
4
5
6
7
8
910111213
3Y
GND
NC
14
13
12
11
10
9
8
CC
V
4Y
V
6A
6Y
5A
5Y
4A
4Y
6A
18
17
16
15
14
4A
CC
6Y
NC
5A
NC
5Y
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
FUNCTION TABLE
(each inverter)
INPUTAOUTPUT
Y
H L
L H
Copyright 2000, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
1
SN54AHCU04, SN74AHCU04
HEX INVERTERS
SCLS234H – OCTOBER 1995 – REVISED JANUARY 2000
logic symbol
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, DB, DGV, J, N, PW, and W packages.
†
1
1A
3
2A 2Y
5
3A 3Y
9
4A 4Y
11
5A 5Y
13
6A 6Y
1
10
12
2
1Y
4
6
8
logic diagram (positive logic)
YA
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI (see Note 1) –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO (see Note 1) –0.5 V to V
Input clamp current, I
Output clamp current, I
Continuous output current, I
(V
< 0) –20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IK
I
(V
OK
< 0 or VO > VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
O
(V
= 0 to VCC) ±25 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
O
O
Continuous current through VCC or GND ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θJA (see Note 2): D package 86°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DB package 96°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DGV package 127°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 80°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package 113°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51.
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
‡
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265