Texas Instruments SN65176BD, SN65176BDR, SN65176BP, SN75176BD, SN75176BDR Datasheet

...
SN65176B, SN75176B
DIFFERENTIAL BUS TRANSCEIVERS
SLLS101B – JULY 1985 – REVISED JUNE 1999
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
Bidirectional Transceivers
D
D
Designed for Multipoint Transmission on Long Bus Lines in Noisy Environments
D
3-State Driver and Receiver Outputs
D
Individual Driver and Receiver Enables
D
Wide Positive and Negative Input/Output Bus Voltage Ranges
D
Driver Output Capability...±60 mA Max
D
Thermal Shutdown Protection
D
Driver Positive and Negative Current Limiting
D
Receiver Input Impedance...12 kΩ Min
D
Receiver Input Sensitivity...±200 mV
D
Receiver Input Hysteresis...50 mV Typ
D
Operate From Single 5-V Supply
description
The SN65176B and SN75176B differential bus transceivers are monolithic integrated circuits designed for bidirectional data communication on multipoint bus transmission lines. They are designed for balanced transmission lines and meet ANSI Standards TIA/EIA-422-B and TIA/EIA-485-A and ITU Recommendations V.11 and X.27.
The SN65176B and SN75176B combine a 3-state differential line driver and a differential input line receiver, both of which operate from a single 5-V power supply . The driver and receiver have active-high and active-low enables, respectively, that can be connected together externally to function as a direction control. The driver differential outputs and the receiver differential inputs are connected internally to form differential input/output (I/O) bus ports that are designed to offer minimum loading to the bus when the driver is disabled or V
CC
= 0. These ports feature wide positive and negative common-mode voltage ranges, making the device suitable for party-line applications.
The driver is designed for up to 60 mA of sink or source current. The driver features positive and negative current limiting and thermal shutdown for protection from line-fault conditions. Thermal shutdown is designed to occur at a junction temperature of approximately 150°C. The receiver features a minimum input impedance of 12 k, an input sensitivity of ±200 mV, and a typical input hysteresis of 50 mV.
The SN65176B and SN75176B can be used in transmission-line applications employing the SN75172 and SN75174 quadruple differential line drivers and SN75173 and SN75175 quadruple differential line receivers.
The SN65176B is characterized for operation from – 40°C to 105°C and the SN75176B is characterized for operation from 0°C to 70°C.
Copyright 1999, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1 2 3 4
8 7 6 5
R RE DE
D
V
CC
B A GND
D OR P PACKAGE
(TOP VIEW)
SN65176B, SN75176B DIFFERENTIAL BUS TRANSCEIVERS
SLLS101B – JULY 1985 – REVISED JUNE 1999
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Function Tables
DRIVER
INPUT ENABLE
OUTPUTS
D DE
A B
H H H L L H L H X L Z Z
RECEIVER
DIFFERENTIAL INPUTS
ENABLE OUTPUT
A–B RE R
VID 0.2 V L H
–0.2 V < VID < 0.2 V L ?
VID – 0.2 V L L
X H Z
Open L ?
H = high level, L = low level, ? = indeterminate, X = irrelevant, Z = high impedance (off)
logic symbol
RE
DE
1
1
2
B
A
7
6
EN2
EN1
R
D
1
4
2
3
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
DE
RE
R
6 7
3
1
2
B
A
Bus
D
4
SN65176B, SN75176B
DIFFERENTIAL BUS TRANSCEIVERS
SLLS101B – JULY 1985 – REVISED JUNE 1999
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematics of inputs and outputs
Output
85 NOM
TYPICAL OF RECEIVER OUTPUT
Input/Output
Port
960 NOM
16.8 k
NOM
TYPICAL OF A AND B I/O PORTS
Driver input: R
(eq)
= 3 k NOM
Enable inputs: R
(eq
)= 8 k NOM
R
(eq)
= equivalent resistor
R
(eq)
V
CC
EQUIVALENT OF EACH INPUT
V
CC
Input
960 NOM
V
CC
GND
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at any bus terminal –10 V to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enable input voltage, V
I
5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 2): D package 197°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P package 104°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential input/output bus voltage, are with respect to network ground terminal.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.
recommended operating conditions
MIN TYP MAX UNIT
Supply voltage, V
CC
4.75 5 5.25 V
p
12
Voltage at any bus terminal (separately or common mode), V
I
or
V
IC
–7
V
High-level input voltage, V
IH
D, DE, and RE 2 V
Low-level input voltage, V
IL
D, DE, and RE 0.8 V
Differential input voltage, VID (see Note 3) ±12 V
p
Driver –60 mA
High-level output current, I
OH
Receiver –400 µA
p
Driver 60
Low-level output current, I
OL
Receiver 8
mA
p
p
SN65176B –40 105
°
Operating free-air temperature, T
A
SN75176B 0 70
°C
NOTE 3: Differential-input/output bus voltage is measured at the noninverting terminal A with respect to the inverting terminal B.
SN65176B, SN75176B DIFFERENTIAL BUS TRANSCEIVERS
SLLS101B – JULY 1985 – REVISED JUNE 1999
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
DRIVER SECTION
electrical characteristics over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS
MIN TYP‡MAX UNIT
V
IK
Input clamp voltage II = –18 mA –1.5 V
V
O
Output voltage IO = 0 0 6 V
|V
OD1
| Differential output voltage IO = 0 1.5 3.6 6 V
|V
OD2
| Differential output voltage
RL = 100 Ω, See Figure 1
1/2 V
OD1
or 2
V
OD2
g
RL = 54 Ω, See Figure 1 1.5 2.5 5 V
V
OD3
Differential output voltage See Note 4 1.5 5 V Change in magnitude of differential output
|VOD|
gg
voltage
§
±0.2
V
p
+3
VOCCommon-mode output voltage
R
L
= 54 Ω or
100 Ω
,
See Figure 1
–1
V
Change in magnitude of common-mode
|VOC|
gg
output voltage
§
±0.2
V
p
Output disabled,
VO = 12 V 1
IOOutput current
,
See Note 5
VO = – 7 V –0.8
mA
I
IH
High-level input current VI = 2.4 V 20 µA
I
IL
Low-level input current VI = 0.4 V –400 µA
VO = –7 V –250
p
VO = 0 150
IOSShort-circuit output current
VO = V
CC
250
mA
VO = 12 V 250
pp
p
Outputs enabled 42 70
ICCSupply current (total package)
No load
Outputs disabled 26 35
mA
The power-off measurement in ANSI Standard TIA/EIA-422-B applies to disabled outputs only and is not applied to combined inputs and outputs.
All typical values are at VCC = 5 V and TA = 25°C.
§
|VOD| and |VOC| are the changes in magnitude of VOD and VOC, respectively, that occur when the input is changed from a high level to a low level.
The minimum V
OD2
with a 100- load is either 1/2 V
OD1
or 2 V, whichever is greater.
NOTES: 4. See ANSI Standard TIA/EIA-485-A, Figure 3.5, Test Termination Measurement 2.
5. This applies for both power on and off; refer to ANSI Standard TIA/EIA-485-A for exact conditions. The TIA/EIA-422-B limit does not apply for a combined driver and receiver terminal.
switching characteristics, VCC = 5 V, RL = 110 kΩ, TA = 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
d(OD)
Differential-output delay time
15 22 ns
t
t(OD)
Differential-output transition time
R
L
= 54 Ω,
See Figure 3
20 30 ns
t
PZH
Output enable time to high level See Figure 4 85 120 ns
t
PZL
Output enable time to low level See Figure 5 40 60 ns
t
PHZ
Output disable time from high level See Figure 4 150 250 ns
t
PLZ
Output disable time from low level See Figure 5 20 30 ns
Loading...
+ 8 hidden pages