Texas Instruments SN64BCT25245DW, SN64BCT25245DWR, SN64BCT25245NT Datasheet

SN64BCT25245
25- OCT AL BUS TRANSCEIVER
SCBS060A – JUNE 1990 – REVISED DECEMBER 1993
Copyright 1993, Texas Instruments Incorporated
3–1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
State-of-the-Art BiCMOS Design
CCZ
Designed to Facilitate Incident-Wave
Switching for Line Impedances of 25 or Greater
Distributed V
CC
and GND Pins Minimize Noise Generated by the Simultaneous Switching of Outputs
Data Flow-Through Pinout (All Inputs
on Opposite Side From Outputs)
High-Impedance State During Power Up
and Power Down
ESD Protection Exceeds 2000 V
Per MIL-STD-883C, Method 3015
Package Options Include Plastic
Small-Outline (DW) Packages and Standard Plastic 300-mil DIPs (NT)
description
The SN64BCT25245 is a 25-octal bus transceiver designed for asynchronous communication between data buses. It improves both the performance and density of 3-state memory address drivers, clock drivers, and bus-oriented transceivers.
The device allows data transmission from the A bus to the B bus or from the B bus to the A bus depending upon the logic level at the direction-control (DIR) input. The output-enable (OE) input can disable the device so that both buses are effectively isolated.
This transceiver is capable of sinking 188-mA IOL, which facilitates switching 25- transmission lines on the incident wave. The distributed VCC and GND pins minimize switching noise for more reliable system operation.
The outputs are in a high-impedance state during power up and power down while the supply voltage is less than approximately 3 V.
The SN64BCT25245 is characterized for operation from –40°C to 85°C and 0°C to 70°C.
FUNCTION TABLE
INPUTS
OE
DIR
OPERATION
L L B data to A bus L H A data to B bus H X Isolation
1 2 3 4 5 6 7 8 9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
A1
GND
A2 A3
GND
A4 A5
GND
A6 A7
GND
A8
DIR B1 B2 V
CC
B3 B4 B5 B6 V
CC
B7 B8 OE
DW OR NT PACKAGE
(TOP VIEW)
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN64BCT25245 25- OCT AL BUS TRANSCEIVER
SCBS060A – JUNE 1990 – REVISED DECEMBER 1993
3–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbol
logic diagram (positive logic)
B2
22
B3
20
B4
19
A5
7
A6
9
A7
10
A8
12
A2
3
A3
4
A4
6
OE
A1
1
G3
13
3EN2[AB]
B5
18
B6
17
B7
15
B8
14
B1
23
3EN1[BA]
24
DIR
DIR
OE
A1
B1
24
1
23
13
To Seven Other Channels
1
2
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI (see Note 1): Control inputs –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I/O ports –0.5 V to 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the disabled or power-off state, V
O
–0.5 V to 7 V. . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state, V
O
(B port) –0.5 V to V
CC
. . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
–30 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state, IO: A port 376 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B port 48 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
IK
Input clamp current –18 mA
p
A port –80
IOHHigh-level output current
B port –3
mA
p
A port 188
IOLLow-level output current
B port 24
mA
T
A
Operating free-air temperature –40 85 °C
Loading...