Texas Instruments SN54HC253J, SN74HC253D, SN74HC253DBR, SN74HC253DR, SN74HC253N Datasheet

...
SN54HC253, SN74HC253
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
D
High-Current Inverting Outputs Drive up to 15 LSTTL Loads
D
Permit Multiplexing from n Lines to One Line
D
Perform Parallel-to-Serial Conversion
D
Package Options Include Plastic Small-Outline (D) and Ceramic Flat (W) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs
description
Each of these data selectors/multiplexers contain inverters and drivers to supply full binary decoding data selection to the AND-OR gates. Separate output-control inputs are provided for each of the two 4-line sections.
The 3-state outputs can interface with and drive data lines of bus-organized systems. With all but one of the common outputs disabled (at the high-impedance state), the low impedance of the single enabled output drives the bus line to a high or low logic level. Each output has its own output-enable (OE
) input. The outputs are
disabled when their respective OE is high. The SN54HC253 is characterized for operation over the full military temperature range of –55°C to 125°C. The
SN74HC253 is characterized for operation from –40°C to 85 °C.
FUNCTION TABLE
INPUTS
SELECT
DATA
OUTPUT
B A C0 C1 C2 C3
OE
Y
X X X X X X H Z
L LLXXXL L L LHXXXL H L HXLXXL L
L HXHXXL H H LXXLXL L H LXXHXL H H HXXXLL L H H X X X H L H
Select inputs A and B are common to both sections.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
SN54HC253 ...J OR W PACKAGE SN74HC253 . . . D OR N PACKAGE
(TOP VIEW)
3212019
910111213
4 5 6 7 8
18 17 16 15 14
A 2C3 NC 2C2 2C1
1C3 1C2
NC 1C1 1C0
SN54HC253 . . . FK PACKAGE
(TOP VIEW)
B
1OE
NC
2Y
2C0
2OE
1Y
GND
NC
V
CC
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10
9
1OE
B 1C3 1C2 1C1 1C0
1Y
GND
V
CC
2OE A 2C3 2C2 2C1 2C0 2Y
NC – No internal connection
Copyright 1997, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN54HC253, SN74HC253 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbol
G
MUX
0 3
0
14
A
1
2
B
EN
1
15
1Y
7
0
6
1C0
1
5
1C1
2
4
1C2
3
3
1C3
10
2C0
11
2C1
12
2C2
13
2C3
2Y
9
1OE
2OE
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, N, and W packages.
SN54HC253, SN74HC253
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic diagram (positive logic)
Pin numbers shown are for the D, J, N, and W packages.
TG
TG
TG
TG
TG
TG
TG
TG
TG
TG
TG
TG
14 2 1
6
5
4
3
15
10
11
12
13
7
9
1OE
A B
1C0
1C1
1C2
1C3
2OE
2C0
2C1
2C2
2C3
1Y
2Y
SN54HC253, SN74HC253 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, IO (VO = 0 to VCC) ±25 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through VCC or GND ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 2): D package 113°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 78°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.
recommended operating conditions
SN54HC253 SN74HC253
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 2 5 6 2 5 6 V
VCC = 2 V 1.5 1.5
V
IH
High-level input voltage
VCC = 4.5 V
3.15 3.15
V VCC = 6 V 4.2 4.2 VCC = 2 V 0 0.5 0 0.5
V
IL
Low-level input voltage
VCC = 4.5 V
0 1.35 0 1.35
V VCC = 6 V 0 1.8 0 1.8
V
I
Input voltage 0 V
CC
0 V
CC
V
V
O
Output voltage 0 V
CC
0 V
CC
V VCC = 2 V 0 1000 0 1000
t
t
Input transition (rise and fall) time
VCC = 4.5 V
0 500 0 500
ns
VCC = 6 V 0 400 0 400
T
A
Operating free-air temperature –55 125 –40 85 °C
SN54HC253, SN74HC253
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
TA = 25°C SN54HC253 SN74HC253
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP MAX MIN MAX MIN MAX
UNIT
2 V 1.9 1.998 1.9 1.9
IOH = –20 µA
4.5 V 4.4 4.499 4.4 4.4
V
OH
VI = VIH or V
IL
6 V 5.9 5.999 5.9 5.9
V IOH = –6 mA 4.5 V 3.98 4.3 3.7 3.84 IOH = –7.8 mA 6 V 5.48 5.8 5.2 5.34
2 V 0.002 0.1 0.1 0.1
IOL = 20 µA
4.5 V 0.001 0.1 0.1 0.1
V
OL
VI = VIH or V
IL
6 V 0.001 0.1 0.1 0.1
V IOL = 6 mA 4.5 V 0.17 0.26 0.4 0.33 IOL = 7.8 mA 6 V 0.15 0.26 0.4 0.33
I
I
VI = VCC or 0 6 V ±0.1 ±100 ±1000 ±1000 nA
I
OZ
VO = VCC or 0 ±0.01 ±0.5 ±10 ±5 µA
I
CC
VI = VCC or 0, IO = 0 6 V 8 160 80 µA
C
i
2 V to 6 V 3 10 10 10 pF
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
FROM TO
TA = 25°C SN54HC253 SN74HC253
PARAMETER
(INPUT) (OUTPUT)
V
CC
MIN TYP MAX MIN MAX MIN MAX
UNIT
2 V 62 150 225 190
A or B Any Y
4.5 V 19 30 45 38 6 V 16 26 38 32
t
pd
2 V 54 126 210 175
ns
Data
Y
4.5 V 16 28 42 35
(Any C)
6 V 13 23 36 30 2 V 28 100 150 125
t
en
OE Y
4.5 V 11 20 30 25
ns 6 V 9 17 26 21 2 V 21 135 203 170
t
dis
OE Y
4.5 V 14 30 45 38
ns 6 V 12 35 38 31 2 V 28 60 90 75
t
t
Y
4.5 V 8 12 18 15
ns 6 V 6 10 15 13
SN54HC253, SN74HC253 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range, CL = 150 pF (unless otherwise noted) (see Figure 1)
FROM TO
TA = 25°C SN54HC253 SN74HC253
PARAMETER
(INPUT) (OUTPUT)
V
CC
MIN TYP MAX MIN MAX MIN MAX
UNIT
2 V 76 235 355 295
A or B Any Y
4.5 V 23 47 71 59 6 V 20 41 60 51
t
pd
2 V 68 220 335 275
ns
Data
Y
4.5 V 20 44 67 55
(Any C)
6 V 17 38 57 51 2 V 44 185 280 230
t
en
OE Y
4.5 V 16 37 56 46
ns 6 V 14 32 48 40 2 V 45 210 315 265
t
t
Y
4.5 V 17 42 63 53
ns 6 V 13 36 53 45
operating characteristics, TA = 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance per multiplexer No load 45 pF
SN54HC253, SN74HC253
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SCLS133B – DECEMBER 1982 – REVISED MA Y 1997
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
VOLTAGE WAVEFORM
INPUT RISE AND FALL TIMES
50%50%
10%10%
90% 90%
V
CC
0 V
t
r
t
f
Input
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
50%
50%50%
10%10%
90% 90%
V
CC
V
OH
V
OL
0 V
t
r
t
f
Input
In-Phase
Output
50%
t
PLH
t
PHL
50% 50%
10% 10%
90%90%
V
OH
V
OL
t
r
t
f
t
PHL
t
PLH
Out-of-Phase
Output
50%
10%
90%
V
CC
V
CC
V
OL
0 V
Output
Control
(Low-Level
Enabling)
Output
Waveform 1
(See Note B)
50%
t
PZL
t
PLZ
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES FOR 3-STATE OUTPUTS
V
OH
0 V
50%
50%
t
PZH
t
PHZ
Output
Waveform 2
(See Note B)
V
CC
Test
Point
From Output
Under Test
C
L
(see Note A)
R
L
V
CC
S1
S2
LOAD CIRCUIT
PARAMETER C
L
t
PZH
tpd or t
t
t
dis
t
en
t
PZL
t
PHZ
t
PLZ
1 k
1 k
50 pF
or
150 pF
50 pF
Open Closed
R
L
S1
Closed Open
S2
Open Closed
Closed Open
50 pF
or
150 pF
Open Open––
NOTES: A. CL includes probe and test-fixture capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following
characteristics: PRR 1 MHz, ZO = 50 Ω, tr = 6 ns, tf = 6 ns. D. The outputs are measured one at a time with one input transition per measurement. E. t
PLZ
and t
PHZ
are the same as t
dis
.
F. t
PZL
and t
PZH
are the same as ten.
G. t
PLH
and t
PHL
are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICA TIONS IS UNDERSTOOD T O BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
Loading...