Datasheet SN54F623J, SN74F623DW, SN74F623DWR, SN74F623N, SNJ54F623FK Datasheet (Texas Instruments)

SN54F623, SN74F623
OCTAL BUS TRANSCEIVERS
WITH 3-STATE OUTPUTS
SDFS087 – MARCH 1987 – REVISED OCTOBER 1993
Copyright 1993, Texas Instruments Incorporated
2–1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Local Bus-Latch Capability
Package Options Include Plastic
Small-Outline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs
description
These octal bus transceivers are designed for asynchronous communication between data buses. The control function implementation allows for maximum flexibility in timing.
These devices allow data transmission from the A bus to the B bus or from the B bus to the A bus depending upon the logic levels at the output enable (OEAB and OEBA
) inputs.
The output-enable inputs can be used to disable the device so that the buses are effectively isolated. The dual-enable configuration gives the transceivers the capability of storing data by simultaneously enabling OEAB and OEBA
. Each output reinforces its input in this configuration. When both OEAB and OEBA
are enabled and all other data sources to the two sets of bus lines are at high impedance, both sets of bus lines (16 in all) will remain at their last states.
The SN54F623 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74F623 is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS
OEBA OEAB
OPERATION
L L B data to A bus L H
B data to A bus,
A data to B bus H L Isolation H H A data to B bus
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
OEAB
A1 A2 A3 A4 A5 A6 A7 A8
GND
V
CC
OEBA B1 B2 B3 B4 B5 B6 B7 B8
SN54F623 ...J PACKAGE
SN74F623 . . . DW OR N PACKAGE
(TOP VIEW)
3 2 1 20 19
9 10 11 12 13
4 5 6 7 8
18 17 16 15 14
B1 B2 B3 B4 B5
A3 A4 A5 A6 A7
SN54F623 . . . FK PACKAGE
(TOP VIEW)
A2A1OEAB
B7
B6
OEBA
A8
GND
B8
V
CC
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN54F623, SN74F623 OCTAL BUS TRANSCEIVERS WITH 3-STATE OUTPUTS
SDFS087 – MARCH 1987 – REVISED OCTOBER 1993
2–2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic symbol
logic diagram (positive logic)
2
A1 B1
EN1
19
EN2
1
OEAB
2
A1
3
A2
B1
18
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
B2
17
B3
16
B5
14
B4
15
B6
13
B8
11
B7
12
OEBA
1
OEBA
OEAB
19
1
182
To Seven Other Channels
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(excluding I/O ports) (see Note 1) –1.2 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current range, I
IK
–30 mA to 5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the disabled or power-off state –0.5 V to 5.5 V. . . . . . . . . . . . . . . . . . . .
Voltage range applied to any output in the high state –0.5 V to V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state: SN54F623 (A1–A8) 40 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN54F623 (B1–B8) 96 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74F623 (A1–A8) 48 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74F623 (B1–B8) 128 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range: SN54F623 –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74F623 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input-voltage ratings may be exceeded provided the input-current ratings are observed.
recommended operating conditions
SN54F623 SN74F623
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
IK
Input clamp current –18 –18 mA
p
A1–A8 –3 –3
IOHHigh-level output current
B1–B8 –12 –15
mA
p
A1–A8 20 24
IOLLow-level output current
B1–B8 48 64
mA
T
A
Operating free-air temperature –55 125 0 70 °C
SN54F623, SN74F623
OCTAL BUS TRANSCEIVERS
WITH 3-STATE OUTPUTS
SDFS087 – MARCH 1987 – REVISED OCTOBER 1993
2–3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
SN54F623 SN74F623
PARAMETER
TEST CONDITIONS
MIN TYP†MAX MIN TYP†MAX
UNIT
V
IK
VCC = 4.5 V, II = – 18 mA – 1.2 – 1.2 V
IOH = – 1 mA 2.5 3.4 2.5 3.4
A1–A8
IOH = – 3 mA 2.4 3.3 2.4 3.3
VCC = 4.5 V
IOH = – 3 mA 2.4 3.3 2.4 3.3
V
OH
B1–B8
IOH = – 12 mA 2 3.2
V
IOH = – 15 mA 2 3.1
Any output VCC = 4.75 V , IOH = – 1 mA to –3 mA 2.7
IOL = 20 mA 0.3 0.5
A1–A8
IOL = 24 mA 0.35 0.5
VOLV
CC
= 4.5
V
IOL = 48 mA 0.38 0.55
V
B1–B8
IOL = 64 mA 0.42 0.55
A and B ports
VI = 5.5 V 1 1
I
I
OEAB or OEBA
V
CC
= 5.5
V
VI = 7 V 0.1 0.1
mA
A and B ports
70 70
I
IH
OEAB or OEBA
V
CC
= 5.5 V,
V
I
= 2.7
V
20 20
µ
A
A and B ports
– 0.65 – 0.65
I
IL
OEAB or OEBA
V
CC
=
5.5 V
,
V
I
=
0.5 V
– 0.6 – 0.6
mA
A1–A8
–60 – 150 –60 – 150
I
OS
§
B1–B8
V
CC
=
5.5 V
,
V
O
=
0
– 100 – 225 –100 – 225
mA
I
CCH
VCC = 5.5 V, Any output = 4.5 V 110 140 110 140 mA
I
CCL
VCC = 5.5 V
OEAB or OEBA = 4.5 V, A1–A8 = GND
110 140 110 140 mA
I
CCZ
VCC = 5.5 V
OEBA or A1–A8 = 4.5 V, OEAB = GND
99 130 99 130 mA
All typical values are at VCC = 5 V, TA = 25°C.
For I/O ports, the parameters IIH and IIL include the off-state output current.
§
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
SN54F623, SN74F623 OCTAL BUS TRANSCEIVERS WITH 3-STATE OUTPUTS
SDFS087 – MARCH 1987 – REVISED OCTOBER 1993
2–4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics (see Note 2)
PARAMETER
FROM
(
INPUT
)
TO
(
OUTPUT
)
VCC = 5 V, CL = 50 pF, RL = 500 , TA = 25°C
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500, TA = MIN to MAX
UNIT
(INPUT)
(OUTPUT)
F623 SN54F623 SN74F623
MIN TYP MAX MIN MAX MIN MAX
t
PLH
1.2 3.6 5.5 1.1 6.8 1.2 6.5
t
PHL
A
B
2.2 4.6 7 1.6 8 1.7 7.5
ns
t
PLH
1.2 3.6 5.5 1.1 6.8 1.2 6.5
t
PHL
B
A
1.7 4.1 6.5 1.6 8 1.7 7.5
ns
t
PZH
3.1 8.1 10.5 2.7 12.4 3.1 12
t
PZL
OEBA
A
2.8 7.1 9.5 2.5 10.3 2.8 10
ns
t
PHZ
1.7 4.1 6.5 1.6 8.3 1.7 7.5
t
PLZ
OEBA
A
1.7 4.1 6.5 1.5 7.4 1.7 7
ns
t
PZH
2.8 7.6 10 2.7 12 2.8 11.5
t
PZL
OEAB
B
2.8 6.6 9 2.8 10 2.9 9.5
ns
t
PHZ
2.2 5.6 8.5 1.9 10 2.2 10
t
PLZ
OEAB
B
3.2 6.6 9 3.1 10.7 3.2 10
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
NOTE 2: Load circuits and waveforms are shown in Section 1.
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICA TIONS IS UNDERST OOD TO BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
Loading...