RC4136, RM4136, RV4136
QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
Continuous-Short-Circuit Protection
D
D
No Frequency Compensation Required
D
Low Power Consumption
D
No Latch-Up
D
Unity Gain Bandwidth...3 MHz Typ
D
Gain and Phase Match Between Amplifiers
D
Designed To Be Interchangeable With Raytheon RC4136, RM4136, and RV4136
D
Low Noise...8 nV√Hz Typ at 1 kHz
description
The RC4136, RM4136, and RV4136 are quad general-purpose operational amplifiers with each amplifier electrically similar to the µA741 except that offset null capability is not provided.
The high common-mode input voltage range and the absence of latch-up make these amplifiers ideal for voltage-follower applications. The devices are short circuit protected and the internal frequency compensation ensures stability without external components.
The RC4136 is characterized for operation from 0°C to 70°C, the RM4136 is characterized for operation over the full military temperature range of –55°C to 125°C, and the RV4136 is characterized for operation from –40°C to 85°C.
AVAILABLE OPTIONS
PACKAGE
T
A
V
IO
max
°
SMALL OUTLINE CHIP CARRIER CERAMIC DIP PLASTIC DIP FLAT
AT 25 C
(D) (FK) (J) (N) (W)
0°C to 70°C 6 mV RC4136D RC4136N
–40°C to 85°C 6 mV RV4136D RV4136N
–55°C to 125°C 4 mV RM4136FK RM4136J RM4136W
The D packages are available taped and reeled. Add the suffix R to the device type (e.g., RC4136DR).
Copyright 1990, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1 2 3 4 5 6 7
14 13 12 11 10
9 8
1IN–
1IN+ 1OUT 2OUT
2IN+
2IN–
V
CC–
4IN– 4IN+ 4OUT V
CC+
3OUT 3IN+ 3IN–
RM4136 ...J OR W PACKAGE
ALL OTHERS ...D OR N PACKAGE
(TOP VIEW)
3212019
910111213
4 5 6 7 8
18 17 16 15 14
4OUT NC V
CC+
NC 3OUT
1OUT
NC
2OUT
NC
2IN+
RM4136 .. . FK PACKAGE
(TOP VIEW)
NC
3IN –
3IN +
2IN –
NC
1IN +
1IN –
4IN –
4IN +
V
CC–
NC – No internal connection
symbol (each amplifier)
+
OUT
IN+
IN–
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematic (each amplifier)
OUT
IN+
IN–
V
CC–
V
CC+
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
RC4136 RM4136 RV4136 UNIT
Supply voltage V
CC+
(see Note 1) 18 22 18 V
Supply voltage V
CC–
(see Note 1) –18 –22 –18 V Differential input voltage (see Note 2) ±30 ±30 ±30 V Input voltage (any input, see Notes 1 and 3) ±15 ±15 ±15 V Duration of output short circuit to ground, one amplifier at a time (see Note 4) unlimited unlimited unlimited Continuous total dissipation See Dissipation Rating Table Operating free-air temperature range 0 to 70 –55 to 125 –40 to 85 °C Storage temperature range –65 to 150 –65 to 150 –65 to 150 °C Case temperature for 60 seconds FK package 260 °C Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds J or W package 300 °C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or N package 260 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–
.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA 25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING
D 800 mW 7.6 mW/°C 45°C 608 mW 494 mW
FK 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
J 800 mW 11.0 mW/°C77°C 800 mW 715 mW 275 mW
N 800 mW 9.2 mW/°C63°C 736 mW 598 mW
W 800 mW 8.0 mW/°C 50°C 640 mW 520 mW 200 mW
RC4136, RM4136, RV4136
QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN MAX UNIT
Supply voltage, V
CC+
5 15 V
Supply voltage, V
CC–
–5 –15 V
electrical characteristics at specified free-air temperature, V
CC+
= 15 V, V
CC–
= –15 V
RC4136 RM4136 RV4136
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX MIN TYP MAX
UNIT
p
25°C 0.5 6 0.5 4 0.5 6
V
IL
Input offset
voltage
VO = 0
Full
range
7.5 6 7.5
mV
p
25°C 5 200 5 1.50 5 200
I
IO
Input offset
current
VO = 0
Full
range
300 500 500
nA
25°C 140 500 140 400 140 500
I
IB
Input bias current VO = 0
Full
range
800 1500 1500
nA
V
i
Input voltage range
25°C ±12 ±14 ±12 ±14 ±12 ±14 V
RL = 10 k 25°C ±12 ±14 ±12 ±14 ±12 ±14
Maxi
mum pea
k
p
RL = 2 k 25°C ±10 ±13 ±10 ±13 ±10 ±13
V
OM
out ut voltage
swing
RL 2 k
Full
range
±10 ±10 ±10
V
Large-signal
25°C 20 300 50 350 20 300
A
VD
gg
differential voltage amplification
V
O
=
±10 V
,
RL 2 k
Full
range
15 25 15
V/mV
B
1
Unity-gain bandwith
25°C 3 3.5 3 MHz
r
i
Input resistance 25°C
0.3*
5
0.3*
5
0.3*
5 M
CMRR
Common-mode rejection ratio
VO = 0, RS = 50 25°C 70 90 70 90 70 90 dB
Supply voltage
k
SVS
yg
sensitivity
V
CC
= ±9 V
to ±15 V
,
25°C 30 150 30 150 30 150 µV/V
SVS
(VIO/VCC)
V
O
=
0
µ
V
n
Equivalent input noise voltage (closed-loop)
AVD = 100, BW = 1 Hz, f = 1 kHz, RS = 100
25°C 8 8 8 nVHz
25°C 5 11.3 5 11.3 5 11.3
I
CC
S
upply curren
t
p
VO = 0, No load
MIN T
A
6 13.7 6 13.3 6 13.7
mA
(all four am lifiers)
MAX T
A
4.5 10 4.5 10 4.5 10
Total power
25°C 150 340 150 340 150 340
P
D
dissipation
VO = 0,
No load
MIN T
A
180 400 180 400 180 400
mW
(all four amplifiers)
MAX T
A
135 300 135 300 135 300
Crosstalk AVD = 100, attenuation
VD
f = 10 kHz,
25°C 105 105 105 dB
(VO1/VO2) RS = 1 k
* This parameter is not production tested.
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified. Full range is 0°C to 70°C for RC4136, –55°C to 125°C for RM4136, and –40°C to 85°C for RV4136. Minimum TA is 0°C for RC4136, –55°C for RM4136, and –40°C for RV4136. Maximum TA is 70°C for RC4136, 125°C for RM4136, and 85°C for RV4136.
RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS072 – MARCH 1978 – REVISED SEPTEMBER 1990
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
operating characteristics, V
CC+
= 15 V, V
CC–
= –15 V, TA = 25°C
RC4136, RV4136 RM4136
PARAMETER
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
t
r
Rise time
V
= 20 mV, R
= 2 k,
0.13 0.13
Overshoot factor
I
,
CL = 100 pF
L
,
5% 5%
µ
s
VI = 10 V, RL = 2 k,
SR
Slew rate at unity gain
I
CL = 100 pF
L
1.7
1.7
V/µs
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICA TIONS IS UNDERST OOD TO BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
Loading...