Needs No Adjustment for Minimum
Temperature Coefficient
D
Surface-Mount Three-Lead Package
description
The LT1009 reference circuit is a
precision-trimmed 2.5-V shunt regulator featuring
low dynamic impedance and a wide operating
current range. The maximum initial tolerance is
±5 mV in the LP package and ±10 mV in the
D package. The reference tolerance is achieved
by on-chip trimming, which minimizes the initial
voltage tolerance and the temperature
coefficient α
Although the LT1009 needs no adjustments, a
third terminal (ADJ) allows the reference voltage
to be adjusted ±5% to eliminate system errors. In
many applications, the LT1009 can be used as a
terminal-for-terminal replacement for the
LM136-2.5, which eliminates the external trim
network.
vz
.
ANODE
NC–No internal connection
logic symbol
ANODECATHODE
D PACKAGE
(TOP VIEW)
NC
1
NC
2
NC
3
4
LP PACKAGE
(TOP VIEW)
ADJ
CATHODE
8
NC
7
CATHODE
6
ADJ
5
ANODE
CATHODE
ADJ
The L T1009 uses include 5-V system references, 8-bit ADC and DAC references, and power-supply monitors.
The device also can be used in applications such as digital voltmeters and current-loop measurement and
control systems.
The L T1009C is characterized for operation from 0°C to 70°C. The L T1009I is characterized for operation from
–40°C to 85°C.
AVAILABLE OPTIONS
PACKAGED DEVICES
T
A
0°C to 70°CLT1009CDLT1009CLP
–40°C to 85°CLT1009IDLT1009ILP
The D and LP packages are available taped and reeled. Add the suffix R to device
type (e.g., LT1009CDR). Chip forms are tested at 25°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
SMALL
OUTLINE
(D)
PLASTIC
CYLINDRICAL
(LP)
FORM
(Y)
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Copyright 1999, Texas Instruments Incorporated
1
LT1009
Operating free-air temperature range, T
°C
2.5-V INTEGRATED REFERENCE CIRCUITS
SLVS013G – MAY 1987 – REVISED NOVEMBER 1999
schematic
Q14Q11
Q8
CATHODE
24 kΩ24 kΩ6.6 kΩ
20 pF
Q2
Q1
Q3
All component values shown are nominal.
absolute maximum ratings over operating free-air temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D and LP packages 260°C. . . . . . . . . . . . .
Storage temperature range, T
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Maximum power dissipation is a function of T
temperature is PD = (T
2. The package thermal impedance is calculated in accordance with JESD 51.
. Operation at the absolute maximum TJ of 150°C can impact reliability.
JA
, and TA. The maximum allowable power dissipation at any allowable ambient
JA
recommended operating conditions
p
2
p
A
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
MINMAXUNIT
LT1009C070
LT1009I–4085
°
PARAMETER
TEST CONDITIONS
T
†
UNIT
25°C
VZReference voltage
I
mA
V
Full range
Adjustment range
25°C
mV
∆V
Full range
mV
ppm/°C
∆V
I
400 µA to 10 mA
mV
I
mA
Ω
PARAMETER
TEST CONDITIONS
UNIT
Adjustment range
mV
LT1009
2.5-V INTEGRATED REFERENCE CIRCUITS
SLVS013G – MAY 1987 – REVISED NOVEMBER 1999
electrical characteristics at specified free-air temperature
A
D package
= 1
Z
V
Z(temp)
α
∆VZ/∆t
z
z
†
Full range is 0°C to 70°C for the LT1009C and –40°C to 85°C for the LT1009I.
‡
The average temperature coefficient of reference voltage is defined as the total change in reference voltage divided by the specified temperature
range.
Forward voltageIF = 2 mA25°C0.410.41V
F
IZ = 1 mA,
V
ADJ
IZ = 1 mA,
V
ADJ
Change in
reference voltage
with temperature
Average
temperature
VZ
coefficient of
reference voltage
Change in
reference voltage
Z
with current
Long-term change
in reference
voltage
Reference
impedance
‡
=
Z
IZ = 1 mA25°C2020ppm/khr
= 1
Z
LP package
D package
LP package
= GND to V
= 0.6 V to VZ – 0.6 V
Z
D package
LP package
°
°
0°C to 70°C152530
–40°C to 85°C20
25°C2.6102.66
Full range1210
25°C0.310.31
Full range1.41.4
LT1009CLT1009I
MINTYPMAXMINTYPMAX
2.492.52.512.492.52.51
2.4952.5 2.505 2.4952.5 2.505
2.4852.515 2.4752.525
2.4912.5092.482.52
125125
4545
515
415
pp
°
electrical characteristics at TA = 25°C
LT1009Y
MINTYPMAX
V
Z
V
F
∆V
Z(temp)
α
VZ
∆V
Z
∆VZ/∆tLong-term change in reference voltageIZ = 1 mA20ppm/khr
z
z
‡
The average temperature coefficient of reference voltage is defined as the total change in reference voltage divided by the specified temperature
range.