Texas Instruments LM336LP-2-5, LM336D-2-5, LM236DR-2-5, LM236D-2-5, LM236LP-2-5 Datasheet

...
CHIP FORM
(Y)
D
Low Temperature Coefficient
D
D
0.27-Dynamic Impedance
D
±1% Tolerance Available
D
Specified Temperature Stability
D
Easily Trimmed for Minimum Temperature Drift
D
Fast Turnon
D
Three-Lead Transistor Package
description
The LM236-2.5 and LM336-2.5 integrated circuits are precision 2.5-V shunt regulator diodes. These monolithic references operate as low-temperature-coefficient 2.5-V zeners with a
0.2- dynamic impedance. A third terminal provided on the circuit allows the reference voltage and temperature coefficient to be easily trimmed.
LM236-2.5, LM336-2.5
2.5-V INTEGRATED REFERENCE CIRCUITS
SLVS063B – NOVEMBER 1988 – REVISED JULY 1999
D PACKAGE
(TOP VIEW)
CATHODE
8
NC
7
NC
6
ADJ
5
ANODE CATHODE
ADJ
CATHODEANODE
symbol
NC
1
NC
2
NC
3
ANODE
NC-No internal connection
4
LP PACKAGE
(TOP VIEW)
ADJ
The series is useful as precision 2.5-V low-voltage references (V
) for digital voltmeters, power
Z
supplies, or operational-amplifier circuitry . The 2.5-V voltage reference makes it convenient to obtain a stable reference from 5-V logic supplies. Devices in this series operate as shunt regulators, and can be used as either positive or negative voltage references.
The LM236-2.5 is characterized for operation from –25°C to 85°C. The LM336-2.5 is characterized for operation from 0°C to 70°C.
AVAILABLE OPTIONS PACKAGED DEVICES
T
A
0°C to 70°C LM336D-2.5 LM336LP-2.5 LM336Y-2.5
–25°C to 85°C LM236D-2.5 LM236LP-2.5
The D package is available taped and reeled. Add the suffix R to the device type (i.e., LM336DR-2.5). Chip forms are tested at 25°C.
SMALL OUTLINE PLASTIC
(D) (LP)
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright 1999, Texas Instruments Incorporated
1
LM236-2.5, LM336-2.5
Operating free-air temperature, T
°C
2.5-V INTEGRATED REFERENCE CIRCUITS
SLVS063B – NOVEMBER 1988 – REVISED JULY 1999
schematic diagram
CATHODE
Q8
20 pF
Q2
Q1
Q3
All component values are nominal
Q7
10 k
30 pF
Q4
Q6
Q5
Q14
24 k
720
Q9
Q12
24 k
Q10
Q11
6.6 k
500 30 k
6.6 k
Q13
ADJ
ANODE
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Reverse current, IR 20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Forward current, IF 10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or LP package 260°C. . . . . . . . . . . . . . .
Storage temperature range, T
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Maximum power dissipation is a function of TJ(max),
ambient temperature is PD = (TJ(max) – TA)/
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.
(see Notes 1 and 2): D package 97°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . .
JA
LP package 156°C/W. . . . . . . . . . . . . . . . . . . . . . . . . .
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
θ
, and TA. The maximum allowable power dissipation at any allowable
θ
JA
JA
. Operating at the absolute maximum TJ of 150°C can impact reliability.
recommended operating conditions
p
2
MIN MAX UNIT
p
A
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
LM236-2.5 –25 85 LM336-2.5 0 70
°