SN54ALS133, SN74ALS133
13-INPUT POSITIVE-NAND GATES
SDAS202B – APRIL 1982 – REVISED DECEMBER 1994
Copyright 1994, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
• Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
description
These devices contain a 13-input positive-NAND
gate. They perform the following Boolean
functions in positive logic:
Y=A
•B•C•D•E•F•G•H•I•J•K•L•M
Y=A
+B+C+D+E+F+G+H+I+J+K+L+M
The SN54ALS133 is characterized for operation
over the full military temperature range of –55°C
to 125°C. The SN74ALS133 is characterized for
operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS A – M
OUTPUT
Y
All inputs H L
One or more inputs L H
logic symbol
†
logic diagram (positive logic)
&
Y
9
1
A
2
B
3
C
4
D
5
E
13
K
14
L
15
M
6
F
7
G
10
H
11
I
12
J
Y
9
1
A
2
B
3
C
4
D
5
E
13
K
14
L
15
M
6
F
7
G
10
H
11
I
12
J
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
SN54ALS133 ...J PACKAGE
SN74ALS133 ...D OR N PACKAGE
(TOP VIEW)
SN54ALS133 . . . FK PACKAGE
(TOP VIEW)
NC – No internal connection
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
A
B
C
D
E
F
G
GND
V
CC
M
L
K
J
I
H
Y
3212019
910111213
4
5
6
7
8
18
17
16
15
14
L
K
NC
J
I
C
D
NC
E
F
AYV
M
G
CC
GND
NC
H
B
NC
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
SN54ALS133, SN74ALS133
13-INPUT POSITIVE-NAND GATES
SDAS202B – APRIL 1982 – REVISED DECEMBER 1994
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54ALS133 –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS133 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS133 SN74ALS133
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
VILLow-level input voltage
I
OH
High-level output current –0.4 –0.4 mA
I
OL
Low-level output current 4 8 mA
T
A
Operating free-air temperature –55 125 0 70 °C
‡
Applies over temperature range –55°C to 70°C
§
Applies over temperature range 70°C to 125°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
V
IK
VCC = 4.5 V, II = –18 mA –1.2 –1.5 V
V
OH
VCC = 4.5 V to 5.5 V, IOH = –0.4 mA VCC–2 VCC–2 V
IOL = 4 mA 0.25 0.5 0.25 0.4
I
I
VCC = 5.5 V, VI = 7 V 0.1 0.1 mA
I
IH
VCC = 5.5 V, VI = 2.7 V 20 20 µA
I
IL
VCC = 5.5 V, VI = 0.4 V –0.1 –0.1 mA
I
O
#
VCC = 5.5 V, VO = 2.25 V –20 –112 –30 –112 mA
I
CCH
VCC = 5.5 V, VI = 0 0.24 0.34 0.24 0.34 mA
I
CCL
VCC = 5.5 V, VI = 4.5 V 0.56 0.8 0.56 0.08 mA
¶
All typical values are at VCC = 5 V, TA = 25°C.
#
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.