Texas Instruments CDC586PAHR, CDC586PAH Datasheet

CDC586
3.3-V PHASE-LOCK-LOOP CLOCK DRIVER WITH 3-STATE OUTPUTS
SCAS336D – FEBRUARY 1993 – REVISED OCTOBER 1998
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
D
Operates at 3.3-V V
CC
D
Distributes One Clock Input to Twelve Outputs
D
Two Select Inputs Configure Up to Nine Outputs to Operate at One-Half or Double the Input Frequency
D
No External RC Network Required
D
External Feedback Pin (FBIN) Is Used to Synchronize the Outputs to the Clock Input
D
Application for Synchronous DRAM, High-Speed Microprocessor
D
TTL-Compatible Inputs and Outputs
D
Outputs Drive Parallel 50- Terminated Transmission Lines
D
State-of-the-Art
EPIC-ΙΙB
BiCMOS Design
Significantly Reduces Power Dissipation
D
Distributed VCC and Ground Pins Reduce Switching Noise
D
Packaged in 52-Pin Thin Quad Flat Package
AV
PAH PACKAGE
(TOP VIEW)
15 16
V
CC
4Y3 GND V
CC
4Y2 GND V
CC
4Y1 GND GND V
CC
3Y3 GND
39 38 37 36 35 34 33 32 31 30 29 28 27
17
1 2 3 4 5 6 7 8 9 10 11 12 13
GND
1Y1
V
CC
GND
1Y2
V
CC
GND
1Y3
V
CC
GND GND
2Y1
V
CC
18 19 20 21
CLKINNCOE
51 50 49 48 4752 46
GND
SEL1
SEL0
AGND
FBIN
AGND
AV
GND
3Y2
V
GND
2Y3
GND
GND
3Y1
44 43 4245
22 23 24 25 26
41 40
14
GND
2Y2
TEST
CLR
CC
CC
CC
V
CC
V
CC
V
CC
NC – No internal connection
description
The CDC586 is a high-performance, low-skew, low-jitter clock driver . It uses a phase-lock loop (PLL) to precisely align, in both frequency and phase, the clock output signals to the clock input (CLKIN) signal. It is specifically designed for use with popular microprocessors operating at speeds from 50 MHz to 100 MHz or down to 25 MHz on outputs configured as half-frequency outputs. The CDC586 operates at 3.3-V V
CC
and is designed to drive
a properly terminated 50-W transmission line.
Copyright 1998, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC-ΙΙB is a trademark of Texas Instruments Incorporated.
CDC586
3.3-V PHASE-LOCK-LOOP CLOCK DRIVER WITH 3-STATE OUTPUTS
SCAS336D – FEBRUARY 1993 – REVISED OCTOBER 1998
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
description (continued)
The feedback input (FBIN) is used to synchronize the output clocks in frequency and phase to CLKIN. One of the twelve output clocks must be fed back to FBIN for the PLL to maintain synchronization between the CLKIN input and the outputs. The output used as the feedback pin is synchronized to the same frequency as the CLKIN input.
The Y outputs can be configured to switch in phase and at the same frequency as CLKIN. Select inputs (SEL1, SEL0) configure up to nine Y outputs, in banks of three, to operate at one-half or double the CLKIN frequency , depending on which pin is fed back to FBIN (see Tables 1 and 2). All output signal duty cycles are adjusted to 50%, independent of the duty cycle at CLKIN.
Output-enable (OE
) is provided for output control. When OE is high, the outputs are in the high-impedance state.
When OE
is low, the outputs are active. TEST is used for factory testing of the device and can be used to bypass
the PLL. TEST should be strapped to GND for normal operation. Unlike many products containing PLLs, the CDC586 does not require external RC networks. The loop filter for
the PLL is included on chip, minimizing component count, board space, and cost. Because it is based on PLL circuitry, the CDC586 requires a stabilization time to achieve phase lock of the
feedback signal to the reference signal. This stabilization time is required following power up and application of a fixed-frequency, fixed-phase signal at CLKIN, as well as following any changes to the PLL reference or feedback signals. Such changes occur upon change of the select inputs, upon enabling of the PLL via TEST, and upon enable of all outputs via OE
.
The CDC586 is characterized for operation from 0°C to 70°C.
detailed description of output configurations
The voltage-controlled oscillator (VCO) used in the CDC586 PLL has a frequency range of 100 MHz to 200 MHz, twice the operating frequency range of the CDC586 outputs. The output of the VCO is divided by two and by four to provide reference frequencies with a 50% duty cycle of one-half and one-fourth the VCO frequency . SEL0 and SEL1 select which of the two signals are buffered to each bank of device outputs.
One device output must be externally wired to FBIN to complete the PLL. The VCO operates such that the frequency and phase of this output match that of the CLKIN signal. In the case that a VCO/2 output is wired to FBIN, the VCO must operate at twice the CLKIN frequency, resulting in device outputs that operate at either the same or one-half the CLKIN frequency. If a VCO/4 output is wired to FBIN, the device outputs operate at twice or the same frequency as the CLKIN frequency.
CDC586
3.3-V PHASE-LOCK-LOOP CLOCK DRIVER WITH 3-STATE OUTPUTS
SCAS336D – FEBRUARY 1993 – REVISED OCTOBER 1998
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
output configuration A
Output configuration A is valid when any output configured as a 1x frequency output in Table 1 is fed back to FBIN. The input frequency range for CLKIN is 50 MHz to 100 MHz when using output configuration A. Outputs configured as 1/2x outputs operate at half the CLKIN frequency , while outputs configured as 1x outputs operate at the same frequency as CLKIN.
Table 1. Output Configuration A
INPUTS
OUTPUTS
SEL1 SEL0
1/2x
FREQUENCY1xFREQUENCY
L L None All L H 1Yn 2Yn, 3Yn, 4Yn H L 1Yn, 2Yn 3Yn, 4Yn H H 1Yn, 2Yn, 3Yn 4Yn
NOTE: n = 1, 2, 3
output configuration B
Output configuration B is valid when any output configured as a 1x frequency output in Table 2 is fed back to FBIN. The input frequency range for CLKIN is 25 MHz to 50 MHz when using output configuration B. Outputs configured as 1x outputs operate at the CLKIN frequency, while outputs configured as 2x outputs operate at double the frequency of CLKIN.
Table 2. Output Configuration B
INPUTS
OUTPUTS
SEL1 SEL0
1x
FREQUENCY2xFREQUENCY
L L All None L H 1Yn 2Yn, 3Yn, 4Yn
H L 1Yn, 2Yn 3Yn, 4Yn H H 1Yn, 2Yn, 3Yn 4Yn
NOTE: n = 1, 2, 3
CDC586
3.3-V PHASE-LOCK-LOOP CLOCK DRIVER WITH 3-STATE OUTPUTS
SCAS336D – FEBRUARY 1993 – REVISED OCTOBER 1998
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
functional block diagram
ОООООО
ОООООО
ОООООО
Phase-Lock Loop
One of Four Identical
Outputs – 1Yn
One of Four Identical
Outputs – 2Yn
One of Four Identical
Outputs – 3Yn
One of Four Identical
Outputs – 4Yn
CLR
CLKIN
TEST
SEL1
SEL0
FBIN
OE
Select
Logic
1Y1–1Y3
2Y1–2Y3
3Y1–3Y3
4Y1–4Y3
CLR
B
2
42
40
48
45
41
50
51
B
2
Loading...