TEXAS INSTRUMENTS CD54AC05, CD74AC05 Technical data

55°C to 125°C
SOIC
M
AC05M
查询AC05M供应商查询AC05M供应商
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
D
D
Speed of Bipolar F, AS, and S, With Significantly Reduced Power Consumption
D
Balanced Propagation Delays
D
±24-mA Output Drive Current – Fanout to 15 F Devices
D
SCR-Latchup-Resistant CMOS Process and Circuit Design
D
Exceeds 2-kV ESD Protection Per
CD54AC05 ...F PACKAGE
CD74AC05 ...E OR M PACKAGE
1A 1Y 2A 2Y 3A 3Y
GND
(TOP VIEW)
1
14
2
13
3
12
4
11
5
10 6 7
9 8
V 6A 6Y 5A 5Y 4A 4Y
CC
MIL-STD-883, Method 3015
description
The ’AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions.
ORDERING INFORMA TION
T
A
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package.
PACKAGE
PDIP – E Tube CD74AC05E CD74AC05E
CDIP – F Tube CD54AC05F3A CD54AC05F3A
Tube CD74AC05M Tape and reel CD74AC05M96
ORDERABLE
PART NUMBER
TOP-SIDE MARKING
FUNCTION TABLE
INPUT
logic diagram, each inverter (positive logic)
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
(each inverter)
OUTPUT
A
H L
L Z
Y
YA
Copyright 2002, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1
CD54AC05, CD74AC05
t/v
Input transition rise or fall rate
ns/V
HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V Input clamp current, I Output clamp current, I Continuous output current, I Continuous current through V Package thermal impedance, θ
–0.5 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
IK
(V
OK
< 0 or V
I
(V
O
O
> VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
< 0 or V
(V
O
or GND ±100 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
(see Note 2): E package 80°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JA
> VCC) (see Note 1) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
O
= 0 to VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M package 86°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
recommended operating conditions (see Note 3)
TA = 25°C MIN MAX MIN MAX MIN MAX
V
Supply voltage 1.5 5.5 1.5 5.5 1.5 5.5 V
CC
VCC = 1.5 V 1.2 1.2 1.2
V
High-level input voltage
IH
V
Low-level input voltage
IL
V
Input voltage 0 V
I
V
Output voltage 0 5.5 0 5.5 0 5.5 V
O
I
High-level output current VCC = 4.5 V to 5.5 V –24 –24 –24 mA
OH
I
Low-level output current VCC = 4.5 V to 5.5 V 24 24 24 mA
OL
p
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
VCC = 3 V 2.1 2.1 2.1 VCC = 5.5 V 3.85 3.85 3.85 VCC = 1.5 V 0.3 0.3 0.3 VCC = 3 V VCC = 5.5 V 1.65 1.65 1.65
VCC = 1.5 V to 3 V 50 50 50 VCC = 3.6 V to 5.5 V 20 20 20
–40°C TO
85°C
0.9 0.9 0.9
CC
0 V
CC
–55°C TO
125°C
0 V
CC
UNIT
V
V
V
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
CC
(INPUT)
(OUTPUT)
A
Y
ns
(INPUT)
(OUTPUT)
A
Y
ns
(INPUT)
(OUTPUT)
A
Y
ns
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
1.5 V 0.1 0.1 0.1
IOL = 50 µA
V
OL
I
I
I
CC
C
T est one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize power dissipation. T est verifies a minimum 50- transmission-line drive capability at 85°C and 75- transmission-line drive capability at 125°C.
i
VI = VIH or V
VI = VCC or GND 5.5 V ±0.1 ±1 ±1 µA VI = VCC or GND, IO = 0 5.5 V 4 40 80 µA
IL
IOL = 12 mA 3 V 0.36 0.44 0.5 IOL = 24 mA 4.5 V 0.36 0.44 0.5 IOL = 50 mA IOL = 75 mA
† †
3 V 0.1 0.1 0.1
4.5 V 0.1 0.1 0.1
5.5 V 1.65
5.5 V 1.65
TA = 25°C MIN MAX MIN MAX MIN MAX
–40°C TO
85°C
10 10 10 pF
–55°C TO
125°C
UNIT
V
switching characteristics over recommended operating free-air temperature range,
= 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
V
CC
PARAMETER
t
PLZ
t
PZL
FROM
TO
–40°C TO
85°C
MIN MAX MIN MAX
–55°C TO
125°C
94 103 74 81
switching characteristics over recommended operating free-air temperature range, V
= 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
CC
PARAMETER
t
PLZ
t
PZL
FROM
TO
–40°C TO
85°C
MIN MAX MIN MAX
3 10.4 2.9 11.5
2.3 8.3 2.3 9.1
–55°C TO
125°C
switching characteristics over recommended operating free-air temperature range,
= 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
V
CC
PARAMETER
t
PLZ
t
PZL
FROM
TO
–40°C TO
85°C
MIN MAX MIN MAX
2.2 7.5 2.1 8.2
1.7 5.9 1.6 6.5
–55°C TO
125°C
UNIT
UNIT
UNIT
operating characteristics, VCC = 5 V, TA = 25°C
C
Power dissipation capacitance
pd
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER TYP UNIT
105
pF
3
CD54AC05, CD74AC05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL = 50 pF
(see Note A)
When VCC = 1.5 V, R1 = R2 = 1 k
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, ZO = 50 Ω, tr 3 ns, tf 3 ns. C. The outputs are measured one at a time with one input transition per measurement.
R1 = 500
R2 = 500
LOAD CIRCUIT
Figure 1. Load Circuit and Voltage Waveforms
S1
2 × V
CC
Input
Output
50% V
CC
t
PZL
50% V
CC
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
50% V
CC
t
PLZ
20% V
V
0 V
V
CC
V
CC
CC
OL
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TIs terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty . Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty . Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. T o minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third–party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party , or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Mailing Address:
Texas Instruments Post Office Box 655303 Dallas, Texas 75265
Copyright 2002, Texas Instruments Incorporated