Texas Instruments CD74HCT163E, CD74HCT161M96, CD74HCT161M, CD74HCT161E, CD74HCT163M96 Datasheet

...
CD74HC161, CD74HCT161,
/ j
/
/
[ /Title (CD74 HC161 , CD74 HCT16 1, CD74 HC163 , CD74 HCT16
3) Sub­ect
(High Speed CMOS Logic Preset­table Counte rs)
Autho
r ()
Key-
words (High Speed CMOS Logic Preset­table Counte rs, High Speed
Data sheet acquired from Harris Semiconductor SCHS154
February 1998
Features
• CD74HC161, CD74HCT161 4-Bit Binary Counter, Asynchronous Reset
• CD74HC163, CD74HCT163 4-Bit Binary Counter, Synchronous Reset
• Synchronous Counting and Loading
• Look-Ahead Carry for High-Speed Counting
• Fanout (Over Temperature Range)
- Standard Outputs. . . . . . . . . . . . . . . 10 LSTTL Loads
- Bus Driver Outputs . . . . . . . . . . . . . 15 LSTTL Loads
o
• Wide Operating Temperature Range . . . -55
• Balanced Propagation Delay and Transition Times
• Significant Power Reduction Compared to LSTTL Logic ICs
• HC Types
- 2V to 6V Operation
- High Noise Immunity: N
at VCC = 5V
• HCT Types
- 4.5V to 5.5V Operation
- Direct LSTTL Input Logic Compatibility,
V
= 0.8V (Max), VIH = 2V (Min)
IL
- CMOS Input Compatibility, I
= 30%, NIH = 30% of V
IL
1µA at VOL, V
l
C to 125oC
Ordering Information
PART NUMBER TEMP. RANGE (oC) PACKAGE
CD74HC161E -55 to 125 16 Ld PDIP E16.3 CD74HC161M -55 to 125 16 Ld SOIC M16.15 CD74HC163E -55 to 125 16 Ld PDIP E16.3 CD74HC163M -55 to 125 16 Ld SOIC M16.15 CD74HCT161E -55 to 125 16 Ld PDIP E16.3 CD74HCT161M -55 to 125 16 Ld SOIC M16.15 CD74HCT163E -55 to 125 16 Ld PDIP E16.3 CD74HCT163M -55 to 125 16 Ld SOIC M16.15
NOTES:
1. When ordering,usetheentire partnumber.Addthesuffix 96 toob­tain the variant in the tape and reel.
2. Waferand die for this part number is availablewhich meets allelec­trical specifications. Please contact your local sales office or Harris customer service for ordering information.
CD74HC163, CD74HCT163
High Speed CMOS Logic
Presettable Counters
Description
The Harris CD74HC161, CD74HCT161, CD74HC163 and CD74HCT163 are presettable synchronous counters that feature look-ahead carry logic for use in high-speed counting applications. The CD74HC161 and CD74HCT161 are asynchronous reset decade and binary counters, respectively; the CD74HC163 and CD74HCT163 devices decade and binary counters, respectively and are reset synchronously with the clock. Counting and parallel presetting are both accomplished synchronously with the negative-to-positive transition of the clock.
A low level on the synchronous parallel enable input, SPE, disables countingoperation and allows data at the P0 to P3 inputs to be loaded into the counter (provided that the setup and hold requirements for SPE are met).
All counters are reset with a low level on the Master Reset input, MR. In the CD74HC163 and CD74HCT163 counters (synchronous reset types), the requirements for setup and hold time with respect to the clock must be met.
Two count enables, PE and TE, in each counter are
CC
provided for n-bit cascading. In all counters reset action
OH
PKG.
NO.
occurs regardless of the level of the (and the clock input, CP, in the CD74HC161 and CD74HCT161 types).
If a decade counter is preset to an illegal state or assumes an illegal state when power is applied, it will return to the normal sequence in one count as shown in state diagram.
The look-ahead carry feature simplifies ser ial cascading of the counters. Both count enable inputs (PE and TE) must be high to count. The TE input is gated with the Q outputs of all four stages so that at the maximum count the terminal count (TC) output goes high for one clock period. This TC pulse is used to enable the next cascaded stage.
Pinout
CD74HC161, CD74HCT161, CD74HC163, CD74HCT163
(PDIP, SOIC)
TOP VIEW
1
MR
2
CP
3
P0
4
P1
5
P2
6
P3
7
PE
8
GND
SPE, PE and TE inputs
16
V
CC
TC
15 14
Q0
13
Q1
12
Q2 Q3
11 10
TE
9
SPE
CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper IC Handling Procedures. Copyright
© Harris Corporation 1998
1
File Number 1550.1
CD74HC161, CD74HCT161, CD74HC163, CD74HCT163
Functional Diagram
P0 P1 P2 P3
3456
SPE
CP
MR
PE
TE
9
2
1
7
10
14
Q0
13
Q1
12
Q2
11
Q3
15
TC
MODE SELECT - FUNCTION TABLE FOR CD74HC/HCT161
INPUTS OUTPUTS
OPERATING MODE
MR CP PE TE SPE P
n
Q
n
TC
Reset (Clear) L XXXXXLL Parallel Load H XXl l LL
H X X l h H (Note 3) Count H h h h (Note 5) X Count (Note 3) Inhibit H X I (Note 4) X h (Note 5) X q
H X X I (Note 4) h (Note 5) X q
n
n
(Note 3)
L
MODE SELECT - FUNCTION TABLE FOR CD74HC/HCT163
INPUTS OUTPUTS
OPERATING MODE
MR CP PE TE SPE P
n
Q
n
TC
Reset (Clear) l XXXXLL Parallel Load h (Note 5) XX l l LL
h (Note 5) X X l h H (Note 3) Count h (Note 5) h h h (Note 5) X Count (Note 3) Inhibit h (Note 5) X I (Note 4) X h (Note 5) X q
h (Note 5) X X I (Note 4) h (Note 5) X q
n
n
(Note 3)
L
NOTE: H = High voltage level steady state; L = Low voltagelevel steady state; h = High voltage level one setup time prior to the Low-to-High clock transition; l = Low voltage level one setup time prior to the Low-to-High clock transition; X = Don’t Care; q = Lower case letters indicate the state of the referenced output prior to the Low-to-High clock transition; = Low-to-High clock transition.
3. The TC output is High when TE is High and the counter is at Terminal Count (HHHH for CD74HC/HCT161 and CD74HC/HCT163).
4. The High-to-Low transition of PE or TE on the CD74HC/HCT161 and the CD74HC/HCT163 should only occur while CP is HIGH for con­ventional operation.
5. The Low-to-Hightransition of SPEon the CD74HC/HCT161and SPEor MR onthe CD74HC/HCT163 should only occurwhile CP isHIGH for conventional operation.
2
CD74HC161, CD74HCT161, CD74HC163, CD74HCT163
Absolute Maximum Ratings Thermal Information
DC Supply Voltage, VCC. . . . . . . . . . . . . . . . . . . . . . . . -0.5V to 7V
DC Input Diode Current, I
IK
For VI < -0.5V or VI > VCC + 0.5V. . . . . . . . . . . . . . . . . . . . . .±20mA
DC Output Diode Current, I
OK
For VO < -0.5V or VO > VCC + 0.5V . . . . . . . . . . . . . . . . . . . .±20mA
DC Drain Current, per Output, I
O
For -0.5V < VO < VCC + 0.5V. . . . . . . . . . . . . . . . . . . . . . . . . .±25mA
DC Output Source or Sink Current per Output Pin, I
O
For VO > -0.5V or VO < VCC + 0.5V . . . . . . . . . . . . . . . . . . . .±25mA
DC VCC or Ground Current, ICC . . . . . . . . . . . . . . . . . . . . . . . . .±50mA
Operating Conditions
Temperature Range, TA . . . . . . . . . . . . . . . . . . . . . . -55oC to 125oC
Supply Voltage Range, V
HC Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2V to 6V
HCT Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5V to 5.5V
DC Input or Output Voltage, VI, VO . . . . . . . . . . . . . . . . . 0V to V
Input Rise and Fall Time
2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000ns (Max)
4.5V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500ns (Max)
6V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400ns (Max)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
6. θJA is measured with the component mounted on an evaluation PC board in free air.
CC
Thermal Resistance (Typical, Note 6) θJA (oC/W)
PDIP Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
SOIC Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . 150oC
Maximum Storage Temperature Range . . . . . . . . . .-65oC to 150oC
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . .300oC
(SOIC - Lead Tips Only)
CC
DC Electrical Specifications
PARAMETER SYMBOL
HC TYPES
High Level Input Voltage
Low Level Input Voltage
High Level Output Voltage CMOS Loads
High Level Output Voltage TTL Loads
Low Level Output Voltage CMOS Loads
Low Level Output Voltage TTL Loads
Input Leakage Current
V
IH
V
IL
V
OH
V
OL
I
I
TEST
CONDITIONS
(V) IO(mA) MIN TYP MAX MIN MAX MIN MAX
I
V
CC
(V)
o
C -40oC TO 85oC -55oC TO 125oC
25
UNITSV
- - 2 1.5 - - 1.5 - 1.5 - V
4.5 3.15 - - 3.15 - 3.15 - V 6 4.2 - - 4.2 - 4.2 - V
- - 2 - - 0.5 - 0.5 - 0.5 V
4.5 - - 1.35 - 1.35 - 1.35 V 6 - - 1.8 - 1.8 - 1.8 V
VIHor VIL-0.02 2 1.9 - - 1.9 - 1.9 - V
-0.02 4.5 4.4 - - 4.4 - 4.4 - V
-0.02 6 5.9 - - 5.9 - 5.9 - V
- - ---- - - - V
-4 4.5 3.98 - - 3.84 - 3.7 - V
-5.2 6 5.48 - - 5.34 - 5.2 - V
VIHor VIL0.02 2 - - 0.1 - 0.1 - 0.1 V
0.02 4.5 - - 0.1 - 0.1 - 0.1 V
0.02 6 - - 0.1 - 0.1 - 0.1 V
- - ---- - - - V 4 4.5 - - 0.26 - 0.33 - 0.4 V
5.2 6 - - 0.26 - 0.33 - 0.4 V
VCC or
-6--±0.1 - ±1-±1 µA
GND
3
Loading...