CY54/74FCT377T
2
Maximum Ratings
[2, 3]
(Above which the useful life may be impaired. For user
guidelines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature
with Power Applied......................................–65°C to +135°C
Supply Voltage to Ground Potential............... –0.5V to +7.0V
DC Input Voltage ........................................... –0.5V to +7.0V
DC Output Voltage......................................... –0.5V to +7.0V
DC Output Current (Maximum Sink Current/Pin) ......120 mA
Power Dissipation..........................................................0.5W
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Function Table
[1]
Operating
Mode
Inputs Outputs
CP CE D O
Load “1” l h H
Load “0“ l l L
Hold
X
h
H
X
X
No Change
No Change
Operating Range
Range Range
Ambient
Temperature V
CC
Commercial All –40°C to +85°C 5V ± 5%
Military
[4]
All –55°C to +125°C 5V ± 10%
Electrical Characteristics Over the Operating Range
Parameter Description Test Conditions Min. Typ.
[5]
Max. Unit
V
OH
Output HIGH Voltage VCC=Min., IOH=–32 mA Com’l 2.0 V
VCC=Min., IOH=–15 mA Com’l 2.4 3.3 V
VCC=Min., IOH=–12 mA Mil 2.4 3.3 V
V
OL
Output LOW Voltage VCC=Min., IOL=64 mA Com’l 0.3 0.55 V
VCC=Min., IOL=32 mA Mil 0.3 0.55 V
V
IH
Input HIGH Voltage 2.0 V
V
IL
Input LOW Voltage 0.8 V
V
H
Hysteresis
[6]
All inputs 0.2 V
V
IK
Input Clamp Diode Voltage VCC=Min., IIN=–18 mA –0.7 –1.2 V
I
I
Input HIGH Current VCC=Max., VIN=V
CC
5 µA
I
IH
Input HIGH Current VCC=Max., VIN=2.7V ±1 µA
I
IL
Input LOW Current VCC=Max., VIN=0.5V ±1 µA
I
OS
Output Short Circuit Current
[7]
VCC=Max., V
OUT
=0.0V –60 –120 –225 mA
I
OFF
Power-Off Disable VCC=0V., V
OUT
=4.5V ±1 µA
Notes:
1. H = HIGH Voltage Level
h = HIGH Voltage Level one set-up time prior to the LOW-to-HIGH Clock Transition
L = LOW Voltage Level
l = LOW Voltage Level one set-up time prior to the LOW-to-HIGH Clock Transition
X = Don’t Care
Z = HIGH Impedance
= LOW-to-HIGH clock transition
2. Unless otherwise noted, these limits are over the operating free-air temperature range.
3. Unused inputs must always be connected to an appropriate logic voltage level, preferably either VCC or ground.
4. T
A
is the “instant on” case temperature.
5. Typical values are at V
CC
=5.0V, TA=+25˚C ambient.
6. This parameter is specified but not tested.
7. Not more thanone output should be shorted ata time. Duration of short shouldnot exceed one second.The use of high-speed test apparatusand/or sample
and holdtechniques are preferable inorder to minimize internal chipheating and more accurately reflectoperational values. Otherwiseprolonged shorting of
a high output may raisethe chip temperature well above normal and thereby cause invalidreadings in other parametric tests. In any sequence of parameter
tests, I
OS
tests should be performed last.