EN
Axial duct CV fan
PASSPORT / SERVICE INSTRUCTION
RU
Вентилятор осевой канальный CV
ПАСПОРТ / ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ
APPLICATION
Axial duct fan TEVIN of CV model (hereinafter referred to as fan) is an exhaust fan manufactured in
the following sizes: 150, 160, 200, 250 and 300 mm. Used in domestic exhaust ventilation.
ATTENTION!
• Electrical connection should be done by a qualified electrician!
• An obligatory element of the electrical system is a switch in which the distance between
the contacts of all poles is at least 3 mm.
• Fan grounding is required.
• Appropriate measures should be taken to avoid the return of gases to the room from a
chimney or other appliances with an open flame.
• CV type fans should not be used in rooms with a high amount of humidity, as well as
where explosive substances are located.
• The manufacturer reserves the right to make design changes.
• The device is not intended to be used by persons (including children) with reduced
physical, brain or mental abilities or in the absence of experience or knowledge if they are
not under control or instructed on the use of the device by the person responsible for their
safety. Children should be supervised in order to prevent playing with the device.
ORGANIZATION OF TEVIN FAN OF CV MODEL
The fan consists of:
1. aluminum profiled blades;
2. case for installation in the duct. Made of galvanized iron or sheet metal with a polymer coating
resistant to corrosion and mechanical damage;
3. individual single-phase asynchronous motor (S1), which can operate continuously. It is characterized
by quiet work in relation to efficiency.
3
MAIN TECHNICAL SPECIFICATIONS
Характеристики CV-150 CV-160 CV-200 CV-250 CV-300
Diameter, mm 150 160 200 250 300
Power consumption, W 30 30 30 42 58
Productive capacity, m
Pressure, Pa 40 50 55 65 75
Noise level, dB(A) 50 51 54 57 62
Voltage, V/Hz 230/50
Engine speed, obr./ min. 1300
Current consumption, А 0,19 0,20 0,25 0,30 0,40
Work temperature,
Mass, kg 1.40 1.50 1.57 2.78 4.21
Degree of protection, IP X2
Insulation class I
Bearing type Slide
Material Galvanized steel
Dimensions of an individual box:
length, mm
Width, mm 165 165 210 260 320
Heights, mm 205 205 240 300 320
3
/h 270 280 350 600 1000
о
С 42
175 175 215 260 320
DIMENSIONS
Мodel d A E
CV-150 150 215 33
CV-160 160 215 33
CV-200 200 215 33
CV-250 250 280 33
CV-300 300 310 60
Ød
A
4
INSTALLATION AND PREPARATION FOR WORK
Due to possible damage during transportation after unpacking the fan, you need to check:
• power line (for the presence of cracks on the isolating material);
• fan case (for the presence of dents, deformations), fan blades should not be in contact with the case.
If the above damage is not detected, you can proceed with the installation of the fan at the destination:
• prepare electrical wiring;
• fix the fan in the ventilation duct;
• attach the nozzles to the case;
• tighten the nozzles with the trap strap so that the strap was in the grooves on the case.
CV fans are installed:
• directly in the building wall (part of the canal);
• between the ventilation ducts.
CONNECTION SCHEME
5