INSTRUCTION MANUAL
ARGOS-1200
High-performance power supplies
Argos 1200 Page 1 von 16 ISSUE 07/05
TABLE OF CONTENTS
1. Frontpanel layout description
2. Backpanel layout description
3. Installation
4. Constant voltage operation with current limiting
5. Constant current operation with voltage limiting
6. Sensing compensation
7. External programming
8. Overvoltage protection
9. Serial mode
10. Parallel mode
11. Tracking
12. Monitor and Status outputs
13. Over temperature protection
14. Appendix
15. References to special equipments
Argos 1200 Page 2 von 16 ISSUE 07/05
TECHNICAL SPECIFICATIONS
Model Output Voltage Output Current
Argos 30-40 Argos 40-30 Argos 60-20 Argos 100-12
Argos 160-7,5 Argos 200-6 Argos 250-4,8 Argos 300-4
Argos 350-3,4 Argos 500-2,4 Argos 1000-1,2
Argos 1200-1
Electrical Specifications
Constant voltage mode with adjustable current limiting
Output:
Ground isolated, floating up to 500 VDC (1000V)
Voltage adjustment range:
From Vo 0,1 V up to V rated with a 10-Turn Potentiometer
Regulation accuracy:
LINE: 0.01% by +/- 10% line fluctuation LOAD: 0.025% no load to full load measured at sensing terminals
Recovery time:
10ms for a load change from 5% to 100% and regulation within 100mV 10ms for a load change from 100% to 5% and regulation within 100mV 5ms for a load change fof 30% and regulation within 50mV
Ripple:
30mVrms, 120 mVss
Temperature coefficient:
0.01%/K measured within a 0... + 50°C range
Short circuit protection:
Automatic current limiting adjustable from 100mA to rated current
Compensation:
1 V or 1% maximum drop per load line 1)
Constant current mode with adjustable voltage limiting
Current adjustment range
Continuously from 100mA up to rated current adjustable with a 10 -turn potentiometer
Regulation accuracy:
LINE: 0.01% by +/-10% line fluctuation LOAD: 0.1% from full load to short circuit
Temperature coefficient:
0.01%/K measured in a range of 0... +50°C
:
1) Wichever greater
0 - 30V 0 - 40V 0 - 60V 0 - 100V 0 - 160V 0 - 200V 0 - 250V 0 - 300V 0 - 350V
0 - 500V 0 -1000V 0 -1200V
0 – 40A 0 – 30A 0 – 20A
0 – 12A 0 – 7,5A 0 – 6,0A 0 – 4,8A 0 – 4,0A 0 – 3,4A 0 – 2,4A 0 – 1,2A 0 – 1,0A
Physical-Specifications
Physical Specifications:
Dimensions:
H x W x D (without function elements , however with rearpanel connectors): 88x443x390 mm
: appr.14,5 kg
Weight
General Specifications
Design principle
External programming:
Remote ON/OFF control input 0-10V programming input for V = 0-100% 0-10V programming input for C = 0-100% 0-12V programming input for OV = 0-120% 2 monitor outputs: 0-10V for V and C = 0-100%
IEEE-488 / RS 232 listener/talker interface (optional)
Operation modes : Voltage regulation with adjustable current limiting, current regulation with adjustable voltage limiting. (The switching over from one mode to the other is done automatically)
Displays:
Analog meters for voltage and current Cl . 2.5
Storage temperature:
Operating temperature:
Cooling:
Forced cooling, internal fan, suction area in the front, blowing through rearpanel.
Line-voltage input:
230V AC +/-10% 47...65Hz
Current-consumption:
Approx. 7,0A by 230V inrush current limited on rated current
Options:
Opt.04: Power-factor-control Opt.07: 115V Opt.34: IEEE-488/RS232 listener/talker interface Opt.50: Digital display (LED) Opt.99: 19" rack mounting kit
Accessories
Manual Main-power cable with plugs
AC
Input voltage
: switching mode
-20...+70°C
0... +50°C without derating
Argos 1200 Page 3 von 16 ISSUE 07/05
1. Frontpanel layout description
2 3 10 12
8
12
4
0
16
20
V
VOLTAGE CURRENT
89
CV
CC
50 100
25
0
200
250
A
OV-RES
OV-ADJ
+ TEST -
11
REN OT
7
156
POWEREXTERN
14
1
1 Power switch
2 Voltage output display
3 Current output display
4 Voltage adjustment control (10 turn pot)
5 Current adjustment control (10 turn pot)
6 External/internal switch and External LED indicator
7 Remote enable indicator
8 LED indicator for constant voltage mode
9 LED indicator for constant current mode
10 Adjustment control for the OV-protection
11 Overvoltage reset button and overvoltage LED indicator
12 Power ON indicator
13 Test sockets for output voltage
14 Ventilation slits
15 Overtemperature (OT) indicator
CAUTION
14
4
513
Fig. 1
The test sockets (13) are not appropriate to draw current
1
Argos 1200 Page 4 von 16 ISSUE 07/05
2. Backpanel layout description (see Fig.2)
REAR PANEL WITH OPT 34
7
3
TB3 TB4
IEE 48 8 ADDRESS
IEEE-488
8
S2
S1
TERMINAL
1
RS232
2
-S -V +S +V
(3,5mm Stereoklinkenbuchse)
6
5
4
Fig. 2
1 Power supply rearpanel
2 +/- Load terminals
3 AC input and main fuse (TB1)
4 Terminal block for +/- sense line and output voltage +V, -V (TB2)
5 Opt 34, IEEE bus interface connector, address switches and RS-232 connector
6 Regulation board with TB3, TB4, S1 and S2
7 Grounding screw
8 Blind frame for switch S1/S2
Argos 1200 Page 5 von 16 ISSUE 07/05
Loading...