Bedienungsanleitung de
Instruction manual en
Mode d’emploi fr
Manual de instrucciones es
Manuale di istruzioni it
Manual de instruções pt
Инструкция по эксплуатации ru
2
Bedienungsanleitung de ........................... 3 - 9
Instruction manual en ........................ 11 - 16
Mode d’emploi fr ........................ 19 - 25
Manual de instrucciones es ........................ 27 - 33
Manuale di istruzioni it ........................ 35 - 41
Manual de instruções pt ........................ 43 - 49
Инструкция по эксплуатации ru ........................ 50 - 55
3Kurzanleitung testo 410-1
Kurzanleitung testo 410-1
À Schutzkappe: Parkposition
Á Flügelrad
 Temperatur-Sensor
à Display
Ä Bedientasten
Å Batteriefach (Rückseite)
Grundeinstellungen vornehmen
Gerät ist aus >
mit
( ) bestätigen:
Temperatureinheit: °C, °F > Strömungseinheit: m/s, km/h, fpm, mph, kts, Beau >
Auto off-Funktion: OFF, ON
Gerät einschalten
drücken.
Displaybeleuchtung einschalten (für 10s)
Gerät ist an >
Anzeigegröße wählen
Gerät ist an > Mit
Strömung, Wind Chill Temperatur ()
Anzeigemodus wählen
Gerät ist an > Mit
Aktueller Messwert > Hold: Messwerte werden gehalten > Max: Maximalwerte > Min:
Minimalwerte> Hold Avg: Zeitlicher Mittelwert, siehe unten
Zeitliche Mittelwertbildung für Strömung
mehrmals drücken, bis Hold und Avg erscheinen > gedrückt
halten bis
gestartet, die aktuellen Messwerte werden angezeigt > Messung
beenden:
Gerät ausschalten
Gerät ist an >
2s gedrückt halten > Mit ( ) auswählen,
drücken.
auswählen:
auswählen:
- - - - erscheint > loslassen: Mittelwertbildung wird
drücken, der Mittelwert wird angezeigt.
2s gedrückt halten.
de
????nlsvptitesfren
Sicherheit und Umwelt4
Sicherheit und Umwelt
Zu diesem Dokument
> Lesen Sie diese Dokumentation aufmerksam durch und
machen Sie sich mit dem Produkt vertraut, bevor Sie es ❯
einsetzen. Bewahren Sie diese Doku menta tion griffbereit auf,
um bei Bedarf nachschlagen zu können. Geben Sie diese
Dokumentation an spätere Nutzer des Produkts weiter.
> Beachten Sie besonders die Informationen, welche durch
folgende Zeichen hervorgehoben sind:
Wichtiger Hinweis.
Personenschäden / Sachschäden vermeiden
> Das Produkt nur sach- und bestimmungsgemäß und innerhalb
der in den Technischen Daten vorgegebenen Parameter
betreiben. Keine Gewalt anwenden.
> Das Produkt nie zusammen mit Lösungs mitteln, Säuren oder
anderen aggressiven Stoffen lagern.
> Nur Wartungs- und Instandhaltungsarbeiten durchführen, die in
der Doku mentation beschrieben sind. Dabei die vor gegebenen
Handlungs schritte einhalten. Nur Original-Ersatzteile von Testo
ver wenden.
Umwelt schützen
> Defekte Akkus und leere Batterien an den dafür vorgesehenen
Sammelstellen abgeben.
> Produkt nach Ende der Nutzungszeit an Testo senden. Wir
sorgen für eine umwelt schonende Entsorgung.
Leistungsbeschreibung 5
Leistungsbeschreibung
Funktionen und Verwendung
Das testo 410-1 ist ein Strömungs- / Temperatur-Messgerät.
Üblicher Verwendungszweck ist die Messung der Luftgeschwindigkeit an Lüftungsauslässen. Ergänzt durch die
gleichzeitige Messung der Temperatur können die Klimabedingungen analysiert werden.
Technische Daten
Messtechnische Daten
· Sensoren:
Kunststoff-Flügelrad,
NTC-Temperatur sensor
· Messgrößen:
m/s, km/h, fpm, mph, kts, Beaufort,
°C, °F, wind chill
· Messbereiche:
0.4...20 m/s, 80... 4000 fpm,
-10...50 °C, 14...122 °F
· Auflösungen:
0.1 m/s, 1 fpm, 0.1 °C, 0.1 °F
· Genauigkeiten
(Nenntemperatur 22 °C, ±1 Digit):
±(0.2 m/s+2 % v. Mw.),
±(40 fpm+2 % v. Mw.),
±0.5 °C, ±0.9 °F
> Gehäuse bei Verschmutzung mit einem feuchten Tuch
(Seifen lauge) reinigen. Keine scharfen Reinigungs- oder
Lösungsmittel verwenden!
Tipps und Hilfe
Fragen und Antworten
Frage Mögliche Ursachen / Lösungen
Hi oder Lo · Messwerte außerhalb des Messbereichs (zu hoch, zu
niedrig): Zulässigen Messbereich einhalten.
· Restkapazität <10min: Batterien wechseln.
Falls wir Ihre Frage nicht beantworten konnten: Wenden Sie sich
bitte an Ihren Händler oder den Testo-Kundendienst. Kontaktdaten siehe Internetseite www.testo.com/service-contact.
deenfresitptsvnl????
Notizen10
Short manual testo 410-1 11
Short manual testo 410-1
À Protection cap: Park position
Á Impeller
 Temperature sensor
à Display
Ä Control keys
Å Battery compartment (on rear)
Basic settings
Instrument off >press and hold
confirm with
Unit of temperature: °C, °F > Unit of velocity: m/s, km/h, fpm, mph, kts, Beau > Auto
off-Funktion: OFF, ON
Switching the instrument on
Press
Switching the display light on (for 10s)
Instrument on > press
Select display size
Instrument on > select with
Velocity, chill temperature ()
Select display mode
Instrument on > select with
Current reading > Hold: Readings are held > Max: Maximum values > Min: Minimum
values > Hold Avg: Timed mean value calculation, see below
Timed mean value calculation for flow
Press
until
- - - - appears > Releasing starts mean value calculation,
the current readings are
displayed > End measurement: press
displayed.
Switching the instrument off:
Instrument on > press and hold
( ):
.
.
several times, until Hold and Avg appear > Hold down
2s > select with ( ),
:
:
the mean value is
,
2s.
de
enfresitptsvnl????
Safety and the enviroment12
Safety and the environment
About this document
> Please read this documentation through carefully and
familiarise yourself with the product before putting it to use.
Keep this document to hand so that you can refer to it when
necessary. Hand this documentation on to any subsequent
users of the product.
> Pay particular attention to information emphasised by the
following symbols:
Important.
Avoid personal injury/damage to equipment
> Only operate the measuring instrument properly, for its
intended purpose and within the parameters specified in the
technical data. Do not use force.
> Never store the product together with solvents, acids or other
aggressive substances.
> Only carry out the maintenance and repair work that is
described in the documentation. Follow the prescribed steps
when doing so. Use only OEM spare parts from Testo.
Protecting the environment
> Take faulty rechargeable batteries as well as spent batteries to
the collection points provided for them.
> Send the product back to Testo at the end of its useful life. We
will ensure that it is disposed of in an environmentally friendly
manner.
Specifications 13
Specifications
The testo 410-1 is a flow/temperature measuring instrument. It is
normally used to measure the air speed at ventilation outlets. In
addition to the measurement of temperature, climatic conditions
can also be analysed.
Technical data
Measurement data
· Sensors:
Plastic impeller,
NTC temperature sensor
· Accuracies
(Nominal temperatue 22 °C, ±1 Digit):
±(0.2 m/s +2 % of reading),
±(40 fpm +2 % of reading),
±0.5 °C, ±0.9 °F
· Measuring rate:
0.5 s
Further instrument data
· Protection class: IP10
· Ambient conditions:
-10...50 °C, 14...122 °F
· Storage/transport conditions:
-40...70 °C, -40...158 °F
· Voltage supply:
2x 1.5 V type AAA
· Battery life:
100 h (without display light)
· Dimensions:
133x46x25 mm (inc. protection cap)
· Weight: 110 g (inc. batteries and
protection cap)
Directives, standards and tests
· EC Directive: 2014/30/EU
Warranty
· Duration: 2 years, warranty conditions:
see www.testo.com/warranty
de
enfresitptsvnl????
Product description14
Product description
At a glance
À Protection cap: Park position
Á Impeller
 Temperature sensor
à Display
Ä Control keys
Å Battery compartment (on rear)
First steps
ã Inserting batteries:
1 To open the battery compartment, push the battery cover
down.
2 Insert batteries (2x 1.5 V type AAA). Observe the polarity!
3 To close the battery compartment, push the battery cover
back on.
ã Basic settings (configuration mode):
Adjustable functions
· Unit of temperature: °C, °F
· Unit of velocity: m/s, km/h, fpm, mph, kts, Beau
· Auto off function: OFF, ON (instrument switches off automatically if no key is
pressed for 10 minutes)
1 When switching the instrument on, press and hold until
and appear on the display (configuration mode).
- The adjustable function is displayed. The current setting
flashes.
2 Press
3 Press
4 Repeat steps 2 and 3 for all functions.
- The instrument changes to measuring mode.
( ) several times until the desired setting flashes.
( ) to confirm the input.
Using the product 15
Using the product
To ensure correct readings, align the instrument so that it has
its back to the flow.
ã Switching the instrument on:
> Press
- Measuring mode is opened.
ã Switching the display light on:
3 The instrument is switched on.
> Press
- The display light goes out automatically if no key is
ã Changing the parameter:
The parameter in the top display line can be changed. The
bottom display line always shows the temperature.
Adjustable parameters
· Velocity
· Wind chill temperature (
ambient temperature at temperatures <10°C / <50°F and wind speeds
>1.34m/s / >264 fpm)
> Press several times until the desired parameter appears.
ã Changing the display view:
Adjustable views
· Current reading
· Hold: Readings are held.
· Max: Maximum values since the instrument was last switched on or last reset.
· Min: Minimum values since the instrument was last switched on or last reset.
· Hold Avg: Timed mean value calculation, see below.
> Press several times until the desired view appears.
.
.
pressed for 10 seconds.
): perceived temperature (only deviates from
de
enfresitptsvnl????
Using the product16
ã Timed mean value calculation for flow:
1 Press several times, until Hold and Avg appear in the
display. The last result of mean value calculation is
displayed.
2 Hold
mean value calculation automatically, the
current readings are displayed.
3 End measurement: press
4 For further mean value calculation: hold down
5 End mean value calculation: press
ã Resetting Max/Min values:
1 Press
2 Press
3 Repeat steps 1 and 2 for all values that are to be reset.
ã Switching the instrument off:
> Press
down until - - - - appears. Releasing starts
. The mean value is displayed.
briefly.
several times until the desired view appears.
and hold until - - - - appears.
and hold until the display goes out.
.
Maintaining the product 17
Maintaining the product
â Changing batteries:
1 To open the battery compartment, push the battery cover
down.
2 Remove used batteries and insert new batteries
(2x 1.5 V type AAA). Observe the polarity!
3 To close the battery compartment, push the battery cover
back on.
â Cleaning the housing:
> Clean the housing with a moist cloth (soap suds) if it is dirty.
Do not use aggressive cleaning agents or solvents!
Tips and assistance
Questions and answers
Question Possible causes/solutions
Hi or Lo · Readings outside the measuring range (too high, too
low): Keep to the permitted measuring range.
· Residual capacity <10 min: Change batteries.
de
enfresitptsvnl????
If we could not answer your question, please contact your dealer
or Testo Customer Service. For contact details, please visit www.
testo.com/service-contact.
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.