13
Technical data, testo 875 and testo 881
–
640 x 480 pixels
640 x 480 pixels
–
640 x 480 pixels
only IR image
only IR image/
only real image/
IR and real image
only IR image/
only real image/
IR and real image
only IR image
only IR image/
only real image/
IR and real image
– –
+350 °C to +550 °C
–
Yes
Yes
–
Yes
– –
Yes
–
–
Yes
Yes Yes
–
optional
–
optional
–
yes (by means of manual
input)
–
yes (by means of manual input)
Centre point
Standard measurement
(1-point)
Standard measurement (1-point)
Hot/Cold Spot Recognition
– –
–
yes (by means of headset)
–
yes (laser classification 635 nm, class 2)
– –
±3 % of mv
(+350 °C to +550 °C)
testo 875-1 testo 875-2 testo 881-1 testo 881-2 testo 881-3
FPA 160 x 120 pixels, a.Si FPA 160 x 120 pixels, a.Si
< 110 mK at +30 °C < 80 mK at +30 °C
3.3 mrad (standard lens), 1.0 mrad (telephoto lens) 3.3 mrad (standard lens), 1.0 mrad (telephoto lens)
9 Hz 33 Hz for EU, otherwise 9 Hz
manual and motor focusmanual manual
8 to 14 µm 8 to 14 µm
–
33° x 25° / 0.4 m
33° x 25° / 0.4 m
–
33° x 25° / 0.4 m
32° x 23° / 0.1 m (standard lens),
9° x 7° / 0.5 m (telephoto lens)
32° x 23° / 0.1 m (standard lens)
9° x 7° / 0.5 m (telephoto lens)
3.5” LCD with 320 x 240 pixels 3.5” LCD with 320 x 240 pixels
4 options
(ironbow, rainbow,blue/red, greyscale)
9 options
(ironbow, rainbow,cold/hot, blue/red, grey, inverted grey, sepia,Testo, ironbow HT)
-20 °C to +100 °C/
0 °C to +280 °C (switchable)
-20 °C to +100 °C/
0 °C to +350 °C (switchable)
±2 °C, ±2 % of mv (-20 °C to +280 °C) ±2 °C, ±2 % of mv (-20 °C to +350 °C)
0.01 to 1 0.01 to 1
manual
Hot/Cold Spot Recognition
Two-point measurement
–
Isotherms
–
–
Min./Max. on area
–
manual
10 mm at 1 m (standard lens),
3 mm at 1 m (telephoto lens)
10 mm at 1 m (standard lens),
3 mm at 1 m (telephoto lens)
.bmt; export options in .bmp, .jpg, .csv .bmt; export options in .bmp, .jpg, .csv
2 GB SD card (approx. 1000 images) 2 GB SD card (approx. 1000 images)
Fast-charging, Li-ion battery can be changed on site Fast-charging, Li-ion battery can be changed on site
4 hours 4 hours
In instrument/in charging station (optional) In instrument/in charging station (optional)
Yes Yes
-15 °C to +40 °C -15 °C to +40 °C
-30 °C to +60 °C -30 °C to +60 °C
20 % to 80 % not condensing 20 % to 80 % not condensing
IP54 IP54
2G 2G
approx. 900 g approx. 900 g
152 x 108 x 262 mm 152 x 108 x 262 mm
Yes Yes
ABS ABS
Windows XP (Service Pack 2), Windows Vista,
USB 2.0 interface
Windows XP (Service Pack 2), Windows Vista,
USB 2.0 interface
2004/108/EC 2004/108/EC
2 years 2 years
USB 2.0 USB 2.0
Infrared image output
Detector type
Thermal sensitivity (NETD)
Field of view/min. focus distance
Geometric resolution (IFOV)
Image refresh rate
Focus
Spectral range
Visual
Optical field/min. focus distance
Image size
Image presentation
Image display
Display options
Video output
Colour palettes
Measurement
Temperature range
High-temperature measurement (optional)
Accuracy
Minimum diameter measurement point
Setting emissivity
Reflected temperature compensation
Imager equipment
Digital camera
Power LEDs
Motor focus
Standard lens (32° x 23°)
Telephoto lens (9° x 7°)
Laser measuring spot marking
Voice recording
Display of surface moisture distribution
Measuring functions
Image storage
File format
Data storage device
Power supply
Battery type
Operating time
Charging options
Mains operation
Ambient conditions
Operating temperature range
Storage temperature range
Air humidity
Protection class of housing
Vibration (IEC 68-2-6)
Physical features
Weight
Dimensions (L x W x H)
Tripod mounting
Housing
PC software
System requirements
Norms, tests, warranty
EU guideline
Warranty