Testo 6621 Specifications

Humidity transmitter
testo 6621
Highly accurate testo humidity sensor with long-term
stability (±2.0% RH)
Optional 2-line LCD display
P2A software for parameterization, adjustment and analysis,
saves time and costs in commissioning and maintenance
Wall version with display
Duct version with display
entire signal chain (1-point, 2-point and analog adjustment)
Adjustment without dismantling the transmitter
2 analog outputs (humidity/temperature), option of 1
passive humidity and temperature analog output
A broad variety of the testo 6621 transmitter is available.
Depending on the application in a room or in a duct,
the corresponding designs can be selected. A display
is available as an option. You can choose between
the housing colours grey and white. The testo 6621 is
persuasive in technical terms thanks to the patented
humidity sensors that guarantee the highest accuracy. The
sensors and the analog outputs can be adjusted, analyzed
and parameterized via the external interface using the P2A
software.
%RH
°C
The testo 6621 is a high-performance transmitter for a low
price. It meets the increasing requirements in automated
building services in terms of accuracy, reliability and safety
and thereby saves energy costs.
www.testo.com
testo 6621 – Humidity transmitter
Technical data
testo 6621 – A01/A03 (wall version)
testo 6621 – A02 (duct version)
Parameters
Humidity
Meas. range 0 to 100% RH (>90% RH only briefly)
Accuracy* ±2.0 %RH (0 to 90 %RH),
Temperature dependency/coefficient
Sensor Testo humidity sensor
Replaceability of sensor Through Testo
Temperature
Meas. range 0 to +60 °C
Accuracy ±0,5 °C / 0,9 °F
Sensor Active signal output: NTC
(not for high humidity processes)
±4 %RH (90 to 100 %RH)
Temperature coefficient: 0.05%/K (gap of 25 °C/77 °F)
Service
(+32 to +140 °F)
Passive signal output: NI1000
Can be done by customer (s. below, Replacement sensors), subsequent 2-point adjustment required
-20 to +70 °C (-4 to +158 °F)
Inputs and outputs
Analog outputs
Number of channels 2 channels (humidity and temperature)
Output type
Measuring rate 1/s
Accuracy of analog outputs
4 to 20 mA (2-wire) 0 to 1/5/10 V (4-wire)
4 to 20 mA ±0,05 mA 0 to 1 V ±2,5 mV 0 to 5 V ±12,5 mV 0 to 10 V ±25 mV
testo 6621 – A01/A03 (wall version)
testo 6621 – A02 (duct version)
General
Housing
Material / colour ABS/
Dimensions 81 x 81 x 26 mm 81 x 81 x 42 mm
Weight 160 g80 g / 90 g (A03)
Display
Display 2-line LCD (optional)
Resolution Humidity: 0.1 %RH
Operation
Parameterization P2A software
Assembly
Cable screw connection None (cable routed
Other features
Protection class IP30 IP65
EMC According to EC directive 2004/108/EEC
Interfaces 1x mini-DIN for connecting PC
Reaction time t90: < 15 s at 2 m/s;
Scaling range -50 to 100 °C / -58 to 212 °F,
pure white (RAL 9010) or light grey
see drawing for probe
Temperature: 0.1 °C/°F
1 x M16 x 1,5 through rear wall opening or break-out opening on bottom)
For calibration and adjustment, please note: The response time may be considerably higher in static air
0 to 100 %RH
Power
Voltage supply 20 to 30 V AC/DC
Current consumption
Output
2-wire current 4 to 20 mA
4-wire voltage 0 to 10V 24 7
* The determination of the measurement uncertainty takes place
according to GUM (Guide to the Expression of Uncertainty in Measurement):
In the determination, the accuracy of the measuring instrument (hysteresis, linearity, reproduceability), the uncertainty contribution of the test site as well as the uncertainty of the adjustment site/works calibration are taken into account. For this purpose, k=2 of the extension factor, the usual value in measurement technology, is used as a basis, corresponding to a trust level of 95%.
Voltage supply [V] Current consumption
[mA]
20 20
24 20
30 30
30 7
20 20
24 22
30 28
Operating conditions
Electronics temperature (housing) (with/without display)
Storage temperature -40 to +70 °C (-40 to +176 °F)
Measuring medium Air in air-conditioning systems or air-
0 to +60 °C/32 to +140 °F (A01/A03), With display: 0 to +50 °C/+32 to +122 °F;
-20 to +70 °C/-4 to +158 °F (A02), With display: 0 to +50 °C/+32 to +122 °F
conditioned rooms