testo 635 User guide

This short manual provides an overview of important functions of the product. Please be sure to read the instuction manual before using the product!
Button functions
Button Functions
Function button (3x): The function depends on the button assignment at the time Change display of the 1st reading line
In configuration mode: Increase value (press and hold to increase rapidly), select option Change display of the 2nd reading line
635-1 only: If the Cyclical Printing function is activated, the programmed measuring program is started. Switch instrument on, switch display light on/off;
switch instrument off (press and hold)
Function buttons (Function dependant on profile and setting)
Button Functions
Open (main) menu Enter confirmation Cancel
/ Hold value/display current measurement value
Reset max./min. values to current measurement value Open menu item “Multi-point mean calculation“ Open menu item “Measuring program“ (635-2only) Start test series (635-2 only) End test series (635-2 only), End Cyclical Print (635-1 only) Save values (635-2 only) Open menu item “Material” Open menu item “Radio”
Radio
Mat
Save
End
Start
Measp
Mean
Reset
ACTHold
ESC
OK
Short manual en
testo 635
Humidity/temperature/pressure dew point measuring instrument
Menu overview testo 635-1
Profile menu items Function
Standard Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter Material Activate material characteristic curves cyc. Print De/activate cycle printing
Material Mean Time/point mean calculation
Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter cyc. Print De/activate cycle printing
RadioC Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter Material Activate material characteristic curves cyc. Print De/activate cycle printing
Menu overview testo 635-2
Profile menu items Function
Standard Memory Activate/set measurement locality, print report, delete store
Meas Prog. Set/ de/activate measurement program Mean Time/point mean calculation Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter Material Activate material characteristic curves
Material Memory Messort aktivieren/anlegen, Protokolle drucken, Speicher löschen
Meas Prog. Set/ de/activate measurement program Mean Time/point mean calculation Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter
RadioC Memory Activate/set measurement locality, print report, delete store
Meas Prog. Set/ de/activate measurement program Mean Time/point mean calculation Calc. Calculate water content , dew point, psychrometric temperature,
De/activate differential temperature, set “Alpha” parameter Material Activate material characteristic curves
Important displays
Display Meaning
Battery capacity (only for operation by battery/rechargeable battery):
· 4 segments in the battery symbol are lit: Instrument battery is fully charged
· No segments in the battery symbol are lit: Instrument battery is almost spent
(flashing) Print function: Data are sent to the printer
, Measurement channel no.: Channel 1, channel 2.
If a measurement channel is a radio channel, the radio symbol lights up as well as the measurement channel no.
0976.6351/03/T/dr/07.08.2006
Loading...