testo 106-T1, 106-T2 User guide

The measuring instrument conforms with EN 50081-1 + EN 50 082-1; 1992.The instruments were tested in the 27-1000 MHz frequency range.
Instruction manual
testo 106-T1/-T2
testo 106-T1
testo 106-T2
Accessories
TopSafe
testo 106-T2
testo 106-T1
Wall holder
Protective cap
Frozen food pre-borer
IP 67
0973.1061/T/PC_qxdwh/12.99
°c
36.5
Bat
0516.8265
0516.0826 0516.0825
> 10 mm
2.
1.
Please note:
- Minimum penetration depth >10 mm to achieve accurate values (Fig. 1).
- Use the pre-borer when measuring the core temperature in frozen food.Then place
the measuring tip in the object to be measured (Fig. 2).
- Risk of injury from measuring tip.
- Maximum ambient and operating temperature (e.g.protect instrument from sunlight).
The warranty is invalid if instruments are inexpertly handled.
Instructions
1.)
2.)
aggressive
Stoffe
4.)
3.)
Avoid:
- Use in corrosive acids or alkalines (Fig. 3).
- Measurements on live parts (Fig. 4).
Technical Data
General
Contact measurement
Operating temperature Storage temperature Including optical alarm
testo 106 - T 1
Battery type 2 x lithium 2032
Battery life
testo 106 - T 2
Battery type 2 x AAA round cells
Battery life Including audible alarm
WARRANTY 1 year
Measuring range Resolution
Accuracy ±0.5°C (-30 to +99,9 °C)
± 1°C or ± 1% of m.v.(remaining range)
the larger value applies
±
0.9 °F (-22 to +212 °F)
± 1.8 °F or ± 1% of m.v.(remaining range)
the larger value applies
-20 °C...+50 °C +4 °F...+120 °F
-40 °C...+70 °C
-40 °F...+158 °F
250 h
250 h
0.1 °C
0.1 °F
-50 °C...+230 °C
-58 °F...+446 °F
Note: The IP 67 protection class is guaranteed only inside the closed TopSafe. If the instrument is kept immersed for a longer period of time, apply grease to inside openings of TopSafe (see arrows).
Battery needs to be changed. Observe correct polarisation of batteries/rechargeable batteries.
Bat
Bat
Bat
Bat
Contact measurement
Measuring: Release but-
ton
Measuring: Release but­ton
Measuring: Press button again
HOLD: Press button
OFF: Press button for 3 s
Automatic switch-off function
ON:Press button briefly
Segment test appears
3 s
3 sec
3 sec
3 sec
Settings
2. Set alarm limit.
3. Decide if alarm is to flash when value is above or below limit
ON:Press buttons simultaneously for 3 seconds.
Instrument switched off
1. Switch between °C / °F
Alarm flashes if value is above limit
Switch over - Alarm flashes if value is below limit
Reduce value Increase value
!ALARM "°E
ε
Hold
888.8
or
!ALARM "°E
ε
Hold
888.8
°C
36.5
°C
36.5
°C
Hold
36.5
ALARM °C
20.0
ALARM °C
19.0
ALARM °C
21.0
°C
°F
! ALARM
ALARM "
! ALARM °C
22.0
10 min
Loading...