Test Equipment Depot Rapport 337 User Manual

99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com
Before Using Rapport 337 1
1. Safety Information 2
Battery Charging & Its Precautions 4
2. Introduction of Rapport337 6
FEATURES 6
Main Functions of RAPPORT337 6
Standard Items 7
Names & Functions of Each Part 8
3. Specifications of Rapport337 13
General Specifications 13
Meter Specifications 14
4. Functional Use 16
Power ON/OFF 16
OSD Setup Screen when Power is on 16
Mode Setup 17
VIDEO TESTER 18
DIGITAL MULTI METER 21
PTZ CONTROLLER 28
UTP CABLE TESTER 33
VIEW INFORMATION 34
MAIN SETTING 34
W A R N I N G
W A R N I N G
Make sure to read through "Safety Information" before using Rapport337.
This basic instruction manual is for users of Rapport337. Starting with the outline of Rapport337, the manual is emphasized on the explanations of its operation, how to be connected to the other devices, how to use every button, and how to set up the system.
It is highly recommended, for those who have handled similar devices as well as for those who are using it for the first time, to read every description line by line, especially cautions, before using the Rapport 337.
And when there is any question when in use or there is any damage, make sure to contact the dealer of your Rapport337.
In the 1st Chapter "Safety Information", warnings and precautions are explained for the safety of users when Rapport337 is in use.
In the 2nd Chapter "Introduction of Rapport337", its features and appearance are explained.
In the 3rd Chapter "Specifications of Rapport337" , the specification of the rapport337 components are explained.
The following is important to use Rapport337 safely.
First of all, read through "the precautions for your safety" before using the system.
Make sure to check the input and output range of voltage or current at every input and output ports of Rapport337 before connecting each of them, so that the system cannot be overloaded when in use.
Set up the range for measuring voltage, current and resistance for their known values and use the maximum range for unknown values to protect the unit from damage.
The following operational environment should be maintained constantly for the proper use of Rapport337.
Temperature : -10~ 50
Relative humidity : 30% ~ 90%
Recharging voltage : 12V ± 10%, above 1A
In the 4th Chapter "Functional Use", the functions of Rapport337 are explained so that the users can use it conveniently.
1
2
W A R N I N G
W A R N I N G
Pay attention to the following precautions when using Rapport337.
Do not use the unit in damp humidity or leaking gas environments.
Do not touch it with wet hands.
Be mindful not to shock or shake the unit while in use to avoid
damage.
Avoid the places of strong magnetism or electric wave, which would cause incorrect measuring.
Be careful not to expose the ports or joints to dirt or liquid.
Make sure to use specified replacement fuses described in the
3rd chapter.
Do not disassemble the Rapport 337.
Do not use the meter function, when the Rapport337 or the lead
set look damaged.
Do not measure resistance when the power is applied to a circuit.
When using the meter function, do not forget to turn on the power
of Rapport337 and set up the proper measurement mode before connecting to a circuit to be measured.
Battery Charging & Its Precautions
With the rechargeable 6 nickel hydrogen (Ni-MH) AA-size batteries placed in, Rapport337 can be charged with an adopter of above DC 12V, 1A, and it takes more than 8 hrs for the battery to be fully charged. The battery operates normally after initial 2 or 3 times of full charging, and it can be used for about 4 hrs and above. The battery charging can be checked on the initial picture of POWER ON, and also confirmed on the VIEW INFORMATION. The battery is recharged when connected to a DC adopter irrespective of the Power slide S/W or button.
Alkaline battery(AA size) is usable for about 2 hrs.
Turn off the power to the circuit to be measured and discharge all high voltage capacitance before starting resistance or continuity tests to avoid damage to the Rapport 337.
Put the finger behind the protecting pad when using a probe.
3
4
- Cautions for Battery -
FEATURES
The following batteries can be used for Rapport337
- (AA)-size alkaline battery (6EA)
- (AA)-size chargeable nickel hydrogen (Ni-MH) battery (6EA)
Use only chargeable nickel hydrogen (Ni-MH) batteries, when charging
batteries,using an adapter to Rapport337.
Place the CHARGE SWITCH "ON" position for recharging.
The CHARGE SWITCH is located on the upper part of battery insert.
(Refer to the figure below)
The performance of batteries can be very different, according to
manufacturers. Please use any reliable brand.
Do not mix batteries of different manufacturers when charging batteries.
Make sure not to disorient the polarization of batteries.
Do not short-circuit or disassemble batteries.
Make sure to check the polarization and the voltage and current
ratings before charging batteries and disconnect the charger immediately should an abnormal situation arise.
As a handy and portable device designed for testing various appliances, for the image-output equipments to be installed, Rapport337 is an efficient tester with useful testing functions, to assist the installation of CCTV, UTP test, communications test, RS-485 communications inspection, etc.
For testing each function, set up modes and capacities to be tested, using the key pad located on the front part of Rapport337.
Main Functions of RAPPORT337
Video tester The video signal and the quality of picture
can be tested, and brightness, color and focus can also be adjusted while the image
is being watched.
Video signal generator mode : lt outputs color
bar Red,Blue and Green screen to allow technician to inspect video monitor or DVR.
Support both PAL & NTSC video signal format.
Multimeter Voltage, current, resistance, short-test can
b e tested.
PTZ Controller The basic operational test of PTZ, and other
tests of focus and image checkup, etc. that
are needed for the installation of PTZ are
possible. It supports RS-485/422 communications mode.
PTZ Protocol Analyzer
It determins which protocol to control your PTZ
Camera from PTZ Controller or DVR. This will guide CCTV installer to understand the Protocol and find the fault device easily.
UPT Cable tester The wiring condition(disconnected, shorted)
of UTP cable can be checked out.
5
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
6
Standard Items
Check the contents of your Rapport337 package with the standard checklist below placing them on a level place.
Rapport337 Main Body
User's Manual
Test Lead Set(Red, Black)
Adapter
Rechargeable AA(Size) Nickel Hydrogen(Ni-MH) Battery (6EA)
Necklace
UTP test Terminal
BNC Video Cable
Car Power jack
Names & Functions of Each Part
Optional Items
Tester Bag
7
8
Part Name Function
Part Name Function
Power LED
Charge
Indicating LED
Data Transmitting
LED
Data Receiving
LED LCD
Key Button Controlling External Devices of Rapport337
MODE Button
SET Button
OSD Button
FAR Button
NEAR Button
TELE Button
WIDE Button
Shift Setup
Button
Red LED is on when the system is switched on
Green LED is on when being charged
Red LED is on when data is transmitted
Red LED is on when data is received
TFT LCD
Mode Select
(Video, Multi Meter, PTZ Control, UTP Test)
It is used when setup is changed
It toggles OSD & POWER on/off
It adjusts PTZ focus (far direction) &
Video Mode Brightness
It adjusts PTZ focus (near direction) &
Video Mode Brightness
It zooms PTZ(zoom in) &
adjusts Video Mode Contrast
It zooms PTZ(zoom out) &
adjusts Video Mode Contrast
It shifts up, down, right, left for PTZ &
for menus & others
Key Button METER PART
Resistance
Button
Voltage Button
Setup Change
Button
Current
Measuring
Button 1
Current
Measuring
Button 2
Current
Measuring
Button 3
HOLD, HELP
Button
Test Lead Connection Test Lead Positioning for Lead Connection
It is used for measuring lower current below 4 mA
It is used for measuring current below 400 mA
It is used for measuring current below 10A
Measuring range can be changed and holded
It indicates position of Red Test Lead for measuring
It indicates position of Red Test Lead for measuring
It indicates position of Red Test Lead for measuring
It measures resistance
It measures voltage
It changes setup of AC/DC,
resistance/continuity test
HELP function
Voltage & Registance
It indicates position of Black Test Lead
Current below 400mA
Current below 10A
109
Part
Name
Function
Input BNC
Output BNC
Communication
Port
Base
Safety hook Up
Safety hook
Down
It inputs external image signal
It outpus input image signal to Rapport337
or internally generated Video Test Signals
It is the port of input & output of communication
signal.(Rx+, Rx-,Tx+,Tx-)
It braces Rapport337
It hangs on the neck for safety
It hangs on the neck for safety
Part
Name
UTP Jack
AUX Jack
DC Power Jack
Power S/W
Function
Test jack for UTP cable
Audio, AUX input port
(function to be added when upgraded)
DC power input jack(for over DC12V,1A)
ON/Off main power supply
1211
General Specifications
Meter Specifications
Electric
Characteristic
Image
PTZ
operation test
UTP Cable
Test Size
Input Voltage
Battery
Built-in Charger
TV Type
Image level
Protocol
Transmission
speed
Transmission
mode
Kinds of test
W(88mm) X L(190mm) X T(58mm max)
12V ± 10%, above 1A
Chargeable Ni-MH battery 6EA (AA size)
Charging Time Operation time
NTSC/PAL
1 Vpp, 140 IRE
Multi-Protocol support
2400bps ~ 38400bps
RS-422,RS-485
direct/cross cable, and broken or short-circuit
can be tested
Above 8 hrs
More than 4 hrs
Measuring
Item Measuring
DC Voltage
AC Voltage
DC Current
Measured Value
400mV
4V
4V
400V
4V
40V
400V
400uA
4mV
4mA
40mA
400mV
400mA
10A
10A
Minimum
100uV
1mV
10mV
100mV
1mV
10mV
100mV
0.2uA
2uA
20uA
200uA
2mA
Accuracy
±(0.8% + 2dgts)
±(1.0% + 2dgts)
±(1.2% + 3dgts)
(40Hz ~ 500Hz)
±(1.0% + 2dgts)
±(1.5% + 2dgts)
±(2.0% + 3dgts)
1413
Power ON/OFF
Measuring
Item Measuring
AC Current
Resistance
Continuity
Rated fuse
Measured Value
400uA
4mV
4mA
40mA
400mV
400mA
10A
10A
400
4
40
400
4
40
Beeper is activated when the resistance is below 80
Minimum
0.2uV
2uV
20uV
200uV
2mV
0.1
10
100
10
1
1
250 Volt 800 mA
Accuracy
±(1.5% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
±(1.8% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
±(3.0% + 4dgts)
40Hz ~ 500Hz
±(1.0% + 4dgts)
±(1.0% + 2dgts)
±(2.0% + 4dgts)
±(3.0% + 5dgts)
The Power slide switch is located on the side of Rapport337.
Turn the Power slide switch on, and press to start the Rappor337. To turn off the system, press more than 3 sec. Then, POWER OFF is displayed on the main screen with a beep. Release the button.
The power goes off.
A rechargeable battery should be plugged in over 8 hrs for full charge. The charged battery can operate for 4 hrs or so.
When the battery indicator shows below [][], recharge it for use.
(Full charge : [][][][])
OSD Setup Screen when Power is on
When power is on, the setup OSD is displayed, and it enters automatically to the video test mode after 3 ~ 5 sec. The initial OSD displays its RAPPORT337 version and the initial setup on the screen.
Product Version : 3.01 Firmware Version : 3.02 Initial Protocol : PELCO-D TV mode : NTSC/PAL automatic setup Battery indicator : [][][][] RAPPORT :
Model & software versions are subject to be changed without any further notice.
User's name(Name can be changed in Main menu.)
1615
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
Mode Setup
LCD Screen is changed in order of VIDEO 󱈓 METER 󱈓 PTZ 󱈓 UTP whenever key is pressed once.
MODE SELECT window displays on LCD screen when key is
pressed more than 3 sec.
Press key after selecting the mode you want, using the shift setup key.
Video Tester Mode :
At this mode, the image quality of the external input picture signal is tested, or the monitor, etc. is tested by using the picture signal that is output from PATTERN GENERATOR mode.
Digital Multimeter mode :
At this mode, voltage, current, & continuity are tested.
PTZ Controller mode :
At this mode, the basic movement of up, down, right, left for PTZ is made,
and zooming & manual focus are adjusted.
View Information mode : At this mode, the basic information of RAPPORT337 can be seen. (version, battery residual, communications protocol, & speed.)
Main Setting mode : At this mode, the basic setup of RAPPORT337 can be changed. (user's name, auto power off time, beeper, brightness, contrast, etc.)
HELP : HELP image relevant to the mode displays when the key
is pressed on for more than 2 sec. at each mode. How to use each mode is explained at each HELP menu.
VIDEO TESTER
Connect the output terminal of video output system to the video input BNC of RAPPORT337. Connect the video output BNC of RAPPORT337 to the video input terminal of system.
UTP Cable Tester mode : UTP cable, direct & cross cable, disconnection, and short circuit are
tested.
17
18
OSD Screen Setup
VIDEO : Indicates that the system is in video test mode.
NTSC : Indicates if input or output video signal system is NTSC or
PAL. Input video signal is output on LCD screen by automatic checking without a special setup key, and output video signal
system in Pattern Generator mode can be switched to NTSC or
PAL, using or key.
B[][][][] : Indicates screen brightness, and the brightness increases
gradually by +1 when key is pressed, and decreases
gradually by -1 when key is pressed. And it returns to the initial setup value when one of the two keys is pressed for more
than 3 sec.
C [][][][] : Indicates screen sharpness, and the brightness increases
Enter the PATTERN GENERATION MODE when key is pressed in VIDEO mode.
Output video system is changed to NTSC or PAL, using
or key. Output pattern can be seen COLOR BAR, RED, BLUE, GREEN or its reverse order, using or key.
COLOR BAR RED BLUE GREEN
Press key as PATTERN GENERATION MODE returns to Video MODE.
gradually by +1 when key is pressed, and decreases gradually by -1 when key is pressed. And it returns to the initial setup value when one of the two keys is pressed for more
than 3 sec.
19
20
DIGITAL MULTI METER
Voltage, current, resistance, continuity can be tested.
W A R N I N G
To prevent an electric shock, injury or damage to RAPPORT337, cut off the power supply of the circuit, and discharge all the high-voltage capacity before testing resistance and continuity.
When applying the meter function by using your RAPPORT337, make sure to turn on its power and set up the proper mode before connecting the test lead set to the circuit to be tested.
Description of METER MODE LCD WINDOW
SETUP of KEY SELECT
First, press button, and then press button to be changed to OHM/BUZZ
First, press button, and then press button to be changed to ACV/DCV.
This button is used to test current below 4mA.
This button is used to test current below 400mA.
This button is used to test current below 10A.
21
Part
Function
Kinds of test to
set up
Test value to
display
Measured value
graph
Measured value
in hold
MODE display
Description
- Resistance test
- Continuity test
- Set up tests of DC/AC voltage, current
- unit of resistance test is indicated
- Indicator of AC or DC value of voltage or current
- AC voltage & current are indicated as rms (root mean square)
- Input measured value is indicated in the form of graph
Graph is changed automatically equal to the measured value in automatic mode
OVER is displayed when higher value is measured than the setup value
The measured value is stored and indicated here, when SET key is pressed at the moment of the value measured
Digital Multi Meter Mode is displayed
22
Part
MEASURING RESISTANCE
The unit of resistance is Ω. The meter sends low current into the circuit so that resistance can be measured. This current runs all the paths between probes, and the measured resistance value is all values added among them.
Function
DC AC
OHM
VOLT
AMP
Description
DC Voltage test AC Voltage test
Resistance test (Measuring unit : )
Voltage test (Measuring unit : V) Current test (Measuring unit : mA, A)
Continuity test (Starting to beep at below 80)
TESTING CONTINUITY
Continuity means the presence of a complete path for current to flow. And the continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display.
How to measure : Connect the red lead to and the black lead to , as shown in the figure above at left. and measure the resistance directly at the resistance measuring mode, by pressing on the key pad.
23 24
How to test :The resistance mode returns to the continuity mode, when is pressed. The beeper is activated when the resistance between the
red probe and black probe is below 80Ω.
MEASURING AC & DC VOLTAGE
Voltage means the difference in electrical potential between two points. The polarity of AC voltage varies over time, while the polarity of DC is constant over time. The meter displays ac voltage values as rms (root mean square readings. The rms value means the equivalent dc voltage that can produce the same amount of heat in a resistance as the measured sinewave voltage.
How to measure : First, press , the voltage measuring button, and then
select AC or DC by pressing In case of DC to be measured, place the
MEASURING AC & DC CURRENT
Current is simply defined as a flow of electrons running through a conductor. To measure current, you must break the circuit under test, and then place the meter in series with the circuit. The current measuring range of the meter is 10A max.
How to measure : First, turn off the power of the circuit, and, discharge the high voltage capacitor. Fix the red lead into the terminals of mA and 10A in accordance with the value to be measured. Select one of the buttons
& . When & are selected, place the red lead on
mA, and When button is selected, place the red lead on 10A.
red lead on + point, and the black lead on - point, each on the voltage source.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
2625
W A R N I N G
Check for the location of the test lead set at current test mode. Place the red lead at mA only for below 400mA, and place it at 10A when the value to be tested is over 400mA, or the value is unknown.
W A R N I N G
Use it only for the current measuring after checking for the test mode. Especially, after the current mode is selected, there may occur burnout of fuses, damage, or breakdown of the system when the voltage is measured.
PTZ CONTROLLER
How to connect each terminal and LCD screen PTZ Operation Test : The basic operation of PTZ : Up, Down, Left, Right,
and Zoom, and Manual focus controlling are possible, also. The test of various protocols and transmission speed are possible. In order to control PTZ, connect the PTZ communications cables to TX terminal of RAPPORT337.
- PTZ Control Setup Screen
27
ADD Setup Screen Protocol Setup Screen Communications Speed
Setup Screen
28
- Key Board Control Code Screen
- The controlling code of protocol from the key board or DVR is displayed on the screen. Most important, however, is that the communications speed should be of one accord.
SPST : It memorizes PRESET. Setup can range from 1 up to 99. (short
f o r SET PRESET). First, move the camera to the view to be designated , and press
key, and using & keys, place the cursor at the
location of SPST. Then, set up the address that you want to memorize by using & keys, and then, press key one more time. The information of location is stored in SPST
adress.
When you want to know the input signal of an exterior controller, you can see the input data by connecting the communications cable to the RX terminal of the Rapport 337.
How To Control PTZ
PTZ functions (controlling Up, Down, Left, Right), etc. are possible to be tested, by using buttons : FAR/NEAR(FOCUS ADJUSTING), TELE/ WIDE(ZOOM ADJUSTING), and SHIFT SETUP.
FUNCTION SETUP of PTZ
By using the SHIFT SETUP key, adjust GPST / SPST / TOUR /
SPD / MENU displayed on the lower part of LCD screen by pressing SET key once shortly.
GPST : It moves the camera view to the designated preset location.
Setup can be from 1 up to 99. (short for GO TO PRESET). When the cursor runs to GPST position after key is pressed, select the previously memorized PRESET number, using number, using & keys. When the selection is completed, press
key one more time, it moves to the memorized location.
TOUR : It operates TOUR set up at SPST and MENU. Setup can be from
1 up to 99. TOUR can be designated in the MENU of PTZ.
SPD : Place the cursor at the location of SPD, applying the procedures
described above. Total 16 steps(from 1 to 16) of speed are available to be selected using & keys.
MENU : Place the cursor at the location of MENU, applying the procedures
described above. The MENU of PTZ itself is available to be displayed on LCD screen. using key.
C A U T I O N
Make sure to check for communications protocol, transmission
speed, and ID.
29
30
CONTROL SETUP of PTZ
PTZ ADDR is activated on the upper part on LCD screen, when key is pressed more than 3 sec, and, the activated menu can be changed t o PROTOCOL , BAUDRATE by pressing & keys.
PTZ ADDR : Setup of PTZ ID. The initial setup is made 001, and changing ID of PTZ is done by pressing & keys. The setup is available up
to 255 max.
BAUDRATE : Setup of TRANSMISSION SPEED The initial setup is 2.4KBps, it can be made up to 2.4Kbps
~ 38.4Kbps. It is done by pressing & keys.
To escape from PTZ CONTROL SETUP Mode, simply, press the key again.
C A U T I O N
PROTOCOL : Setup of PTZ PROTOCOL The initial setup is made PELCO-D, and changing
t o PELCO-D, PELCO-P, and WONWOO are available, i n accordance with the protocol mode of PTZ. It is done b y pressing & keys.
31
Make sure to check for CAMERA ID, PROTOCOL, BAUDRATE when the test is carried. PTZ operation test can not be done when the setup is different.
32
UTP CABLE TESTER
Connect UTP cable to be tested to UTP port of RAPPORT337, while
connect the other end to UTP tester.
The connected condition of the cable can be checked, by pressing key, after the connection is completed. Direct cable and cross cable can be
classified, and disconnection or short-circuit can be also examined.
Cross cable Short-circuit & Disconnection
VIEW INFORMATION
Mode Setup : First, press key more than 3 sec. and select VIEW
INFORMATION on MODE SELECT MENU, then press key.
󱈾
MAIN SETTING
Mode Setup : First, press key more than 3 sec. and select MAIN SETTING on MODE SELECT MENU, then press key.
󱈾
Direct cable
33
Select the item by pressing & keys. The each setup value can be changed by pressing & keys.
A user can put the name he or she wants at USER NAME by editing.
At SLEEP TIME, power goes OFF automatically, if the button is not
pushed down for a fixed time.
34
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
Loading...