Teryair SN29PG Operation And Maintenance Manual

Product: Needle Scaler
MODEL: SN29PG
FF - MM - 123 REV - 2
Operation & Maintenance Guide
Sheet 1 of 5
ISO 9001 : 2008
Operation & Maintenance Guide
OPERATION:
SN29PG Needle Scalers are rugged, dependable tools designed to give you years of satisfactory service. Follow the instructions mentioned here to enhance the life and performance of your scaler.
DAILY BEFORE OPERATING:
Disconnect and pour in 1 to 2 ounces of recommended oil in to the tool and reconnect hose after blowing out any accumulated dirt in the hose line before connection.
AIR SUPPLY:
Tool should not be operated at air pressure below 5.5 Bar (80psi) and above 6.9 bar (100psi).The correct operating pressure is 6.2 bar (90 psi). Ensure that only 3/8" (10 mm) bore airline is used and all couplings are tight, leakproof and in good condition. The air should be clean, dry and lubricated. Install a FRL unit as close as operation will permit.
RECOMMENDED LUBRICANTS:
LUBRICATION REQUIREMENTS:
Always install a line lubricator on the air line as close to the tool as possible. A Filter Regulator Lubricator unit (FRL) is strongly recommended. Keep the lubricator bowl topped up with recommended grade of oil and check that the oil is reaching the tool. Running the tool without lubrication is likely to cause damage to the components causing premature replacement.
ABOVE 270C - 800F 50C-270C 400F-
800F
BELOW 50C 400F
SHELL Toona R. 72 Toona R. 41 Toona R.27 MOBIL Almo 529 Almo 527 Almo 525 ESSO ----- Arox.EP.65 Arox EP.45 CALTEX Rando Oil 100 Rando Oil 100 Rando Oil 46 CP ----- ----- Airolene Tool Oil TEXACO Regal oil F (R&O) Regal Oil PE (P&E) Regal Oil PE (R&O) DALTRON Silkolene 881 Silkolene 548/T Silkolene 733 BURMAH CASTROL Castrol RD Oil 3 Castrol RD Oil Light Megna SPX DUCKHAM Garnet 7 Garnet 6 Zero Fio 5 STERNOL Merlin 87 Merlin 71 Merlin 54 PETROFINA Purifoc 53 Purifoc 46 Purifoc 32 CHEVRON Vistac Oil 18X Vistac Oil 19X Vistac Oil 9X IND OIL Servo Spyn – 22 ----- -----
Sheet 2 of 5
FF - MM - 123 REV - 2
CAUTION:
Assemble Nipple in the control body (20) (supplied separately).
MAINTENANCE:
To disassemble SN29PG Needle Scaler- Disconnect air supply and loosen socket head bolt(18) on the front tube(06) and slide out front tube(06) from intermediate tube(07). Unscrew socket head bolt(18) on intermediate tube(07) and unscrew it and remove. Along with intermediate tube(07) different parts -Needle(10), spring return(05),Needle holder (09) and Anvil (08) will come out. Separate them from intermediate tube (07) .Now hold housing (01) of the tool in soft jaw vice and unscrew the sleeve (02) from housing (01). Slide out piston (03) from the sleeve (02). Remove ‘O” Rings (04) (19) from sleeve (02). If necessary disassemble the throttle components-By opening the plug throttle valve (12) and carefully pulling out the throttle valve (11), spring throttle valve(13), ‘O’ ring(17) on throttle valve(11) and ‘O’ Ring(14)on plug throttle valve (12). If necessary, punch out the roll pin (16) and remove lever (15 ) from control body (20). Hold AIF of control body(20) in vice and un-screw housing(01) so that rubber grip(21) and control body (20) will be separated.(Note: Usually housing (01) does not need to be dis assembled to remove control body(20) and rubber grip(21). It is recommended that this assembly should not be dismantled.) Clean all metal parts in light solvant and inspect carefully for signs of wear, Replace components that appear worn out or damaged. Coat parts with recommended light oil and reassemble carefully in the reverse sequence.
Loading...
+ 3 hidden pages