TERSUS GeoBee Ntrip TR600 Quick Start Manual

Page 1
Quick Start Guide for GeoBee v1.0
!
Note: David GNSS receiver and Ntrip Modem TR600 are configured well before shipping. Please set up the system according to Chapter 1, David and Ntrip Modem TR600 are ready to work normally after power on.
1. GeoBee System Set up
No.
Name
1
AX3702 GNSS antenna
2
TNC-J to SMA cable 25m
3
David GNSS Receiver
4
DC-2pin AC Power Adapter with 1.2m cable
5
COMM2-7pin to USB & DB9 male cable
6
COMM1-7pin to TR600-DC-2pin & DB9 female cable
7
Ntrip Modem TR600
8
4G antenna for TR600
9
Wi-Fi antenna for TR600
1
2
3
456
7
8
Ntrip Modem
SIM
Internet
12V
DC
DAVID
WiFi ANT
4G ANT
PC
9
Quick Start Guide for GeoBee
Set up the GeoBee system following the figure below, and power up the system.
Figure 1: GeoBee System Set up
Note:
1) Accessing Internet via Ethernet is default while 2G/3G/4G is hot standby.
2) Using 4G antenna only when 2G/3G/4G SIM card is used.
3) For the known phase center coordinates of the AX3702 antenna, the configuration method
is as follows: use the ‘DB9 Female to USB Type A Male converter cable’ to connect the No. 5
cable in Figure 1 and a computer, open Tersus GNSS Center application on the computer, and
type below commands in the command window:
POSAVE OFF
FIX POSITION B L H // B: latitude (degree), L: longitude (degree), H: height (m)
SAVECONFIG
1
Page 2
Quick Start Guide for GeoBee v1.0
2. Status Check
2.1 Check the status of Ntrip Modem TR600
2.2 Check link status using browser
The PWR is steady red to indicate GeoBee is powered normally, ERR is off to indicate
GeoBee is not at abnormal state. The NET is steady green to indicate that it is connected to
Internet. The SVR1 is steady green to indicate that it is connected to the Ntrip Caster normally.
The SVR2 is steady green to indicate that it is connected to the mserver normally. The LAN1 is
steady green to indicate that the Ethernet connection is normal.
Open any browser on your computer (accessible to the Internet) and enter the following URL in
the address bar:
http://geobeecaster2.tersus-gnss.com:2101/Ntrip.html?usr=geobeetest&pwd= xxxxxxxx
in which, replace the geobeetest with the corresponding name of (Ntrip) Client User on the
Ntrip Modem TR600, replace the xxxxxxxx with the corresponding characters of (Ntrip) Client
Password on the Ntrip Modem TR600.
For example, the label shown in Figure 2, following URL should be entered in the address bar
of the browser:
http://geobeecaster2.tersus-gnss.com:2101/Ntrip.html?usr=geobeetest&pwd=sdafDFdd
Figure 2: Label on Ntrip Modem TR600
After a successful login, the link status is shown in Figure 3:
Figure 3: Example of http status view
2