![](/html/da/da23/da23bdce61a2ac78efe334c6d79f344dd571b4518489eba2c0c56e58f99845f3/bg1.png)
TerraWave Solutions® 18x16x10 Heated/Cooled Polycarbonate Enclosures
TerraWave’s polycarbonate heated and cooled enclosure is designed to protect wireless LAN (WLAN) products from
environmental threats such as heat, cold, dust and rain as well as theft and tampering. For enclosure models that are strictly
heated with no vents, it provides NEMA 4X protection. For the enclosure models that are heated and cooled with vents, it
provides NEMA 3R protection. This affordable solution makes it easy to mount and protect wireless products even in harsh
environments. Wi-Fi enclosures are used in nearly all vertical markets where the protection and enhancement of a wireless
network is crucial. These rugged enclosures are extremely affordable and are the lightest weight enclosure solution
TerraWave offers. Every TerraWave heated and cooled enclosure is covered by the Company’s one-year TerraNet warranty
program. For questions and to purchase product, contact a regional sales executive at 210-375-8482, 800-851-4965 or
sales@terrawave.com. Visit www.terrawave.com for additional information.
18x16x10 Heated Polycarbonate
Enclosure with Solid Cover and
Key Lock
18x16x10 Heated Polycarbonate
Enclosure with Solid Cover and
Locking Latches
Features and Benefits
Enclosure houses a pre-set thermostat
•
• Fan turns on at 35°C (95°F) and turns off at 30°C (86°F)
• Heater turns on at 10°C (50°F) and turns off at 20°C (68°F)
• Power consumption of Fan: ~0.1 amp
• Power consumption of Heater: ~0.05 amp
• The 50-Watt heater requires 120 VAC
• Equipped with vents with filters that can be serviced in the field
• Protects RF equipment from elements, theft and tampering
• Supports all major wireless vendors, such as Cisco, Motorola, Aruba,
Meru, Juniper and others
• Can be mounted indoors or outdoors
• Heated enclosures (no vents) provide NEMA 4X protection
• Heated and cooled enclosures (with vents) provide NEMA 3R protection
• Furnished hardware kit includes panel mounting screws and grounding
hardware
• Additional accessories are available
• Includes standard universal mounting plate, pre-drilled holes for jumpers/
bulkhead extenders and strain relief
• All TerraWave polycarbonate enclosures are RoHS compliant
Enclosure Construction
Constructed of thermoplastic material
•
• UL F1 Rated for Outdoor UV Exposure
Finish
Color is light gray with a gloss finish
•
In addition to enclosures for wireless deployments, TerraWave
can design custom enclosures for any application including IP
cameras, switches, routers and more.
*NEMA rating of enclosure only—before modifications and additions
**All TerraWave enclosures have been modified to work in Wi-Fi/WLAN applications
18x16x10 Heated & Cooled
Polycarbonate Enclosure with Solid
Cover and Key Lock
Available Options
Temp. Control:
Fan
•
• Heater
• Vents
Door:
Clear
•
• Solid
Locking Mechanism:
CAT60 Lock
•
• Locking Latches
Bulkhead Antenna
Holes
None
•
• 2
• 4
• 6
Bulkhead Antenna
Hole Sizes
1/2” (RPTNC)
•
• 1/4” (RPSMA)
18x16x10 Heated & Cooled
Polycarbonate Enclosure with Solid
Cover and Locking Latches
Available Accessories
• Additional Power Re-
ceptacle
• Pole Mount Kit
• Wall Mount Kit
• Custom Jumpers
• NEMA Plug
• Lightning Protection
• Replacement Keys
TerraWave's polycarbonate enclosures
have been evaluated for compliance
with the Reduction of Hazardous
Substances (RoHS) Directive 2002/95
and have been determined to not
contain substances in excess of RoHS
Maximum Concentration Levels.
Version 2.5
www.terrawave.com Email: sales@terrawave.com Phone: 210-375-8482 or 800-851-4965 10521 Gulfdale, San Antonio, TX 78216
![](/html/da/da23/da23bdce61a2ac78efe334c6d79f344dd571b4518489eba2c0c56e58f99845f3/bg2.png)
TerraWave Solutions® 18x16x10 Heated/Cooled Polycarbonate Enclosures
Enclosure Dimensions
Enclosure Size A B C D E
19.56" 18.75" 17.75" 14.00" 19.00"
F G H I x J K
18" x 16" x 10"
11.50" 11.00" 10.50" 14.25" x 16.25" 14.00"
L M N O Panel Size
15.25" 19.71" 18.71" 14.16" 16.75" x 14.88"
A: Overall Length with Mounting Feet
B: Mounting Feet Hole Spacing/Length
C: Overall Width
D: Mounting Feet Hole Spacing/Width
E: Overall Enclosure Length
F: Overall Enclosure Height
G: Internal Height
In addition to enclosures for wireless
deployments, TerraWave can design custom
enclosures for any application including IP
cameras, switches, routers and more.
www.terrawave.com Email: sales@terrawave.com Phone: 210-375-8482 or 800-851-4965 10521 Gulfdale, San Antonio, TX 78216
H: Internal Height Above Backplate
I: Internal Panel Mounting Boss Width
J: Internal Panel Mounting Boss Length
K: Mounting Feet Attachment Boss Width
L: Mounting Feet Attachment Boss Length
M: Overall Length with Mounting Flange
N: Mounting Flange Hole Spacing/Length
O: Mounting Flange Hole Spacing/Width
TerraWave's polycarbonate enclosures
have been evaluated for compliance
with the Reduction of Hazardous
Substances (RoHS) Directive 2002/95
and have been determined to not
contain substances in excess of RoHS
Maximum Concentration Levels.
*NEMA rating of enclosure only—before modifications and additions
**All TerraWave enclosures have been modified to work in Wi-Fi/WLAN applications
Version 2.5