![](/html/86/867c/867c6d6994a9b751ceb816daaa09ac51fde7269609f06833aa80c3a1ef0182d0/bg1.png)
Installation Instructions
TWSD16128PHC
Version 1.1 - Page 1
10521 Gulfdale, San Antonio, TX 78216 I www.terrawave.com I Email: sales@terrawave.com I Phone: 210-375-8482
![](/html/86/867c/867c6d6994a9b751ceb816daaa09ac51fde7269609f06833aa80c3a1ef0182d0/bg2.png)
Introduction
The TWSD16128PHC is intended to be used with WLAN / Networking devices. The
TWSD16128PHC is intended to be used both indoors and outdoors and to provide NEMA 3R
protection with cooling and heating.
Maximum internal ambient is 45 Degrees Celsius.
Before installing this product, read these instructions carefully. Failure to follow these
instructions could lead to damaging the product or cause a hazardous condition.
Check the ratings on the products you intend to place inside the enclosure solution to ensure
that this is suitable for your application.
Precautions
Read and understand all instructions before you begin installing the unit
When installing and using this product, basic safety precautions should always be followed to
reduce the risk of electric shock, fire and injury to persons including the following:
All wiring that connects to this equipment must meet applicable local and national building
codes and network wiring standards for communications cable.
WARNING: To prevent the risk of electric shock and equipment damage, disconnect any
and all supply mains connection to the enclosure before installing, maintaining or trouble
shooting this product or any products inside the enclosure.
Retain the instructions for future reference.
Follow all warnings and instructions marked on the product.
Insulation on all cables and wires installed the service center must either be PVC, TFE,
PTFE, FEP, Neoprene, or Polymide.
Never install cable, connectors or jacks in a wet location unless they are specifically designed
for wet locations.
Never install this product during a lightning storm. There is a risk of electric shock from
lightning.
Never touch uninsulated communication wires or terminals.
Disconnect power before cleaning or servicing the unit.
Version 1.1 - Page 2
10521 Gulfdale, San Antonio, TX 78216 I www.terrawave.com I Email: sales@terrawave.com I Phone: 210-375-8482
![](/html/86/867c/867c6d6994a9b751ceb816daaa09ac51fde7269609f06833aa80c3a1ef0182d0/bg3.png)
Do not use liquid cleaners or aerosol cleaners; use a damp cloth for cleaning.
Mount the unit according to these instructions only using the recommended or supplied
hardware.
Wear proper eye protection when using power and hand tools. Follow all safety instructions
provided with the tools.
This unit should only be connected to the type of power source indicated. If you are unsure
of the type of power supply, consult the local power company.
WARNING: Do not overload outlets as this can result in a risk of fire or electrical shock.
Disconnect power should any of the following conditions occur:
• The TWSD16128PHC does not operate normally when following the operating
instructions
• The TWSD16128PHC has been damaged
• The TWSD16128PHC exhibits a distinct change in performance.
Heater / FAN
The TWSD16128PHC includes a heating element as well as a cooling fan to provide
protection to the internal components from extreme temperatures.
CAUTION– Never touch the moving parts of the fan while in operation. Never touch the heat
synch of the heating element while in operation – the heat synch becomes very hot while in
operation and could cause personal injury if touched.
Warning
WARNING: To prevent the risk of electric shock and equipment damage, disconnect any
and all power supply to the enclosure before installing, maintaining or trouble shooting this
product or any products inside the enclosure.
Installation Instructions
Installation Environment
The TWSD16128PHC is intended for both indoor and outdoor use.
Maximum internal ambient is 45 Degrees Celsius.
Version 1.1 - Page 3
10521 Gulfdale, San Antonio, TX 78216 I www.terrawave.com I Email: sales@terrawave.com I Phone: 210-375-8482
![](/html/86/867c/867c6d6994a9b751ceb816daaa09ac51fde7269609f06833aa80c3a1ef0182d0/bg4.png)
Always mount the enclosure with the cord gland facing down (figure 6). Failure to do so
could result in the unit filling with water – this could result in a hazardous condition and failure
of the unit.
(Figure 6)
Cord Gland should face down to ground
WARNING: To prevent the risk of electric shock and equipment damage, disconnect any and
all power supplies to the enclosure before installing, maintaining or trouble shooting this
product or any products inside the enclosure.
Included Components
The TWSD16128PHC consists of the following components:
NEMA 4 Plug
Cooling Thermostat
Heating Thermostat
Heater
Cooling Fan
Mounting plate
Power socket
Terminal Block
Cord Gland
Cable Tie Downs
Version 1.1 - Page 4