TERRATEC PRODUCER/AXON AX 100 mkII Update
English Manual
Version 1.0, status: August 05
CE Declaration
We:
TerraTec Electronic GmbH, Herrenpfad 38, D-41334 Nettetal, Germany
hereby declare that the product:
AXON mkII Update,
to which this declaration refers is in compliance with the following standards or standardiz-
ing documents:
EN 55013, EN 55020
The following are the stipulated operating and environmental conditions for said compli-
ance:
residential, business and commercial environments and small-company environments.
This declaration is based on:
Test report(s) of the EMC testing laboratory
The information in this document is subject to change without notice and shall not be deemed as a warranty by
the seller. No warranties, express or implied, are made with regard to the quality, suitability or accuracy of this
document. The manufacturer reserves the right to change the contents of this document and/or the associated
products at any time without the provision of prior notice to specific persons or organizations. The manufacturer shall not be held liable for damages of any kind arising from the use, or the inability to use this product or
its documentation, even if the possibility of such damage is known. The information in this document is subject
to copyright. All rights are reserved. No part of this manual may be reproduced or transmitted in any form or for
any purpose without the express written permission of the copyright holders. Product and brand names contained in this document are used for identification purposes only. All registered trademarks, product designations or brand names used in this document are the registered property of their respective owners.
Electronic GmbH, 1994 - 2005. All rights reserved (12.08.2005).
2 AXON AX 100 mkII Update (English)
Congratulations!
We're pleased that you have decided to upgrade your AXON AX 100 to the mkII version
with the AXON Soundboard WAVE XTABLE. This upgrade provides quite a few valuable
enhancements, such as the practical integration of a computer editor (PC & MAC) and
over 500 sounds. We urgently recommend that you have the upgrade installed by an expert. While the installation only requires a few steps, it's very important that they are performed correctly. We cannot accept any liability for damage to the device or injury resulting from the failure to follow these instructions.
If you would like to install the upgrade yourself, we will try to provide as much assistance
as possible, of course. We can imagine that you want to take advantage of the new possibilities as quickly as possible—still, please take your time and work slowly and deliberately, with full concentration.
Scope of delivery
Start by making sure that nothing is missing.
The AXON AX 100 mkII Update package should contain the following items:
EPROM
WAVE XTABLE sound board
CD with Editor software
DVD with AXON workshop, interviews and installation guide
1 service request form
1 registration card with the serial number
this manual
Please fill out and return the registration card enclosed in the package to us at your earliest convenience or register online at
support and hotline services.
www.terratec.net/register.htm. This is important for
AXON AX 100 mkII Update (English) 3
Installation guide
1. Gather the tools required for the installation. These should include a high-quality, insulated screwdriver, and if possible an EPROM gripper. With care and experience, you
can also do the job with two small precision screwdrivers. Nevertheless, we urgently
recommend investing in the proper special tool—it may save you a lot of trouble by reducing the risk of damage to the EPROM.
2. You should also perform the work on an antistatic mat and wear an antistatic wrist
strap. EPROMs are highly sensitive components which are extremely vulnerable to
electrostatic charges. Flying sparks may be exciting in interpersonal relationships, but
they can mean instant death for sophisticated electronic devices and their components. Be sure to use extreme caution for this reason.
- Always wear an antistatic wrist strap coupled to the antistatic mat by a pushbutton,
or to a suitable unpainted, grounded metal object such as a radiator or the chassis
of the device.
- If you do not have such a strap at your disposal, always touch a grounded metal
object with both hands to eliminate possible electrostatic charges before touching
electronic components. Substantial charges may build up when wearing shoes
with crepe or plastic soles or clothing made of synthetic materials, or when the
humidity is low (in the winter, for example).
- Leave the components in their protective packaging until you actually need them.
After unpacking them, place them either on the antistatic mat, or on their protective
packaging.
- Antistatic mats and wrist straps are only effective if they are grounded.
3. Ready? If you haven't already done so, disconnect the AXON from the AC power by
unplugging the power cord from the back of the housing. Place the device on the antistatic mat or another clean, grounded surface.
4. Open the housing by removing the 10 screws of the cover with a screwdriver. Place
them someplace where they a) will be easy to find, and b) cannot fall into the open
4 AXON AX 100 mkII Update (English)
housing. While it's not very likely, such accidents have accounted for the occasional
short circuit.
5. Now that the patient is lying in front of you on the operating table with his chest open,
it's time to get down to business. First, identify the EPROM that you need to remove—
the rectangular chip behind the display, roughly in the middle of the board. After all,
we don't want you to put a lot of effort into removing the wrong chip.
6. Carefully apply the EPROM gripper (you're still grounded, aren't you?) and gently lever
the EPROM from its socket. This should only require a minimum of effort. Should you
feel resistance or notice any other problems, stop and be sure that you have applied
the gripper correctly. Do not force it! The same applies if you are using small screwdrivers instead of a gripper. In that case, be sure to work from both sides, alternating
between the left and right. Do not lever one side out completely before starting on the
other. Doing so would risk doing irreparable damage to the delicate pins of the chip or
its socket.
AXON AX 100 mkII Update (English) 5
7. If you've done everything correctly, you should now be looking at the bare socket
without an EPROM—like this:
8. Carefully (!) pick up the new EPROM with the EPROM gripper or your freshly
grounded fingers to insert it into the socket. Please ensure that the notch on the
EPROM matches the notch on the socket and that all of the pins are correctly positioned on their openings. (Also see the illustration under item 10.)
6 AXON AX 100 mkII Update (English)
9. Once the EPROM is correctly aligned, use two fingers to press it home with gentle,
even pressure applied to all of the pins at the same time. Once again, this does not
require undue effort. Do not use force. If you feel resistance, stop immediately. Please
keep an eye on all of the EPROM's pins—it's very easy to bend or even break them
off, which would amount to the destruction of the EPROM.
10. Finished? Then things should look exactly like this. Please note how the notch of the
EPROM matches that of the socket.
AXON AX 100 mkII Update (English) 7
11. You have mastered the first part well. But that's no reason to get overconfident—
please ensure that you are well-grounded for the following steps as well. Carefully remove the AXON Soundboard from its antistatic packaging. Take care not to touch the
components or printed circuits; always handle the board by the edges. The alignment
of the board is correct when the contact strip is located at the top edge and the socket
for the contact pins at the lower left.
12. Next, place the board with the socket on the mating double row of contact pins. Be
sure that the pins and sockets are aligned before pressing the board home.
8 AXON AX 100 mkII Update (English)
13. As you can probably imagine, a great deal of force is not required. Take your time during the installation to make sure that none of the contact pins are bent and that everything fits correctly.
14. Next, secure the board with two screws (left and right of the upper contact strip). The
lower holes are not relevant for the installation.
15. That's it. Replace the cover and secure it with the screws that you carefully set aside
earlier. Finally, reconnect your AXON to an AC socket and test it. If you did everything
correctly, you should now be able to take advantage of all of the AXON update's features.
16. You can also take the wrist strap off now—it's not all that fashionable, after all.