Terra SRM523, SRM543 User Manual

Page 1
dSCR (Digital satellite cable router) multiswitches SRM523, SRM543
EN
Product description
Cascadable single cable multiswitches SRM523 and SRM543 is intended for the distribution of satellite and terrestrial
signals for up to 32 satellite tuners or receivers on each outputs pair.
The series consist of:
SRM523 has 1 pair subscribers outputs (2 outputs) and 1 signal processor. SRM543 has 2 pairs subscribers outputs (4 outputs) and 2 independent signal processors.
The multiswitches have 4 passive SAT IF and 1 active Terrestrial TV trunk lines and 4 x DC power modes for convenient
DC powering options (see chapter „Installation instructions”).
The device ensure an independent access for every subscriber to any SAT IF or Terrestrial TV trunk line.
These multiswitches automatically detect SCR/dSCR mode or legacy format from the receiver. The dSCR switches also feature fully automatic level control, negating the need for any gain or level adjustments in most installations. It’s built into a zinc alloy die cast housing for extreme interference immunity. The housing of multiswitches meets more stringent screening requirements according to EN50083-2, class A.
Control according to EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 V/22 kHz) commands.
According to the standard ETSI EN 303 354 V.1.1.1, TERR TV band amplier of multiswitch type is Launch, selectivity clasication 0.
Safety instructions
Installation of the multiswitch must be done according IEC60728-11 and national safety standards.
The multiswitch is powered from the stabilized power supply +20 V. This voltage is not dangerous to life.
External power supply must have a short circuit protection.
Any repairs must be made by qualied personnel.
To avoid damaging of the multiswitch do not connect the supply voltage until all cables have been connected correctly.
The device shall be mounted in vertical position with RF input connectors on the top side on a wall or other nonamable
surface.
The multiswitch must be xed with steel screws Ø 4-4.5 mm. The screws are not included in a package.
Do not expose multiswitch to moisture or splashing water and make sure no objects lled with liquids, such as vases,
are placed near or on the unit.
Avoid placing the multiswitch next to central heating components or direct sunlight and in areas of high humidity.
No naked ame sources, such as lighted candles, should be placed on multiswitch.
If the multiswitch has been kept in cold conditions for a long time, keep it in warm room no less than 2 hours before powering.
The ventilation should not be impeded by covering the multiswitch with items, such as newspapers, table-cloths, curtains.
The mains socket of external power supply must be easily accessible.
IMPORTANT WARNINGS!
Before connecting any products to a system, it is essential to make sure the system power supply is switched o󰀨. Avoid short-circuit or overload of any power supply. Never “HOT-SWAP” any system components as this may result in damage to the newly introduced or existing components.
The SRM523 and SRM543 multiswitches are intended only for indoor installation or installation in a suitable weatherproof outdoor cabinet (in this case ensure good ventilation conditions).
These multiswitches must not come into contact with moisture or be installed in areas of high humidity or heat.
Suitable for moderate and tropical climates.
Always mount the multiswitch securely to a wall or bulkhead panel so it cannot hang or swing on its coaxial cables as this may strain the internal circuit board and components.
Always connect all of the coaxial cables to the multiswitch before connecting the power. These units are not designed to be “HOT-SWAPPED” or connected to a live system.
Always be sure that connecting cables shield and multiswitch functional grounding clamp have common potential before powering the system. Floating voltages can be created in an un-earthed system which may cause damage and can be dangerous.
Momentary short-circuit of any cables may be enough to damage the sensitive electronics within the multi-switch or the connected system.
Always allow plenty of ventilation around the multi-switch and do not allow it to be covered with materials such as loft insulation.
We recommend at least 5 cm of airspace around the multi-switch. Digital products can get hot to the touch and require
a ow of air to avoid overheating.
SRM523 and SRM543 multiswitches is designed only to work with Ku band Quattro LNBs.
LNB’s and other system equipment connected to the multiswitch SAT H,Lo and H,Hi trunks inputs/outputs can be powered from the same power supply as the multiswitch.
To avoid damage not covered by warranty DO NOT EXCEED MAX. CURRENTS. See “Technical characteristics” for max. current for external equipment. DO NOT OPERATE THE DC POWER TO H TRUNK LINES SWITCH (see Figure 1, pos.17) unless you totally
understand the power demands of the system and conrmed they are 2 A or less. ALWAYS LEAVE THE DC POWER TO H TRUNK LINES SWITCH IN THE "OFF" POSITION when inserting SRM523, SRM543 into an
existing multiswitch installation. Damage caused by current overload is not covered by the manufacturer’s warranty.
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded
according to applicable local and national regulations. Equipment intended for indoor usage only.
Functional grounding. Connect to the main potential equalization.
This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
Vers. 1.02
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
1
Page 2
External view
1716
10
15 11 12 18
13 14
17
16
15 11 12 18
SRM523 SRM543
DC IN 20V
1
2
3
4
5
Terr. TV
H,Hi
V,Hi
H,Lo
V,Lo
DC IN 20V 2A
Power ON
dSCR multiswitch SRM523
Frequency SAT TV range Terr. TV Trunk loss SAT TV Terr. TV Current consumption 2 0 V 270mA max
dSCR / Legacy +Terr.TV DC IN
2
1
On
DC to H lines
950-2150 MHz 47-790 MHz
< 3 dB < 1 dB
Off
Terr. TV
H,Hi
V,Hi
H,Lo
V,Lo
6
7
8
9
10
1
2
3
4
5
DC IN 20V
Terr. TV
H,Hi
Frequency SAT TV range Terr. TV
V,Hi
Trunk loss SAT TV Terr. TV Current consumption 2 0 V 510mA max
H,Lo
V,Lo
DC IN 20V 2A
Power ON
dSCR multiswitch SRM543
2
Pair A
950-2150 MHz 47-862 MHz
dSCR / Legacy +Terr.TV DC IN
1
On
DC to H lines
< 3 dB < 1 dB
2
Pair B
Off
Terr. TV
H,Hi
V,Hi
H,Lo
V,Lo
1
6
7
8
9
Figure 1. External view of the multiswitches
1 – Terrestrial TV trunk input 2 – H, Hi trunk input 3 – V, Hi trunk input 4 – H, Lo trunk input 5 – V, Lo trunk input 6 – Terrestrial TV trunk output 7 – H, Hi trunk output 8 – V, Hi trunk output
11 – Legacy/dSCR output2 (SRM543 pair A) (Legacy/UB+Terr.TV) 12 – Legacy/dSCR output1 (SRM543 pair A) (Legacy/UB+Terr.TV) 13 – Legacy/dSCR output2 (SRM543 pair B) (Legacy/UB+Terr.TV) 14 – Legacy/dSCR output1 (SRM543 pair B) (Legacy/UB+Terr.TV) 15 – DC 20V power input 16 – Power ON indication LED 17 – DC power to H trunk lines switch
18 – Ground clamp 9 – H, Lo trunk output 10 – V, Lo trunk output
All sockets are “F” type.
Installation instructions
Read the safety instruction rst.
Fit multiswich on mounting place and connect it (pay attention to the multiswitch inputs and Quattro LNB outputs marking), connect
the isolated 75 Ω loads to the unused RF output F sockets, power on multiswich using one of 4 powering modes (see Table 1).
Table 1
”DC power
Powering mode
1. Multiswich powered from local PSU (20 V) via DC input
(see Figure 1, pos. 15) . (Recommended for use is PS202F 20 V PSU). H trunk lines are DC isolated from it.
2.Multiswich is powered from local PSU (20 V) via DC input and with DC passing to H trunk lines.
In this mode H trunk lines can power in cascade other multiswiches (without PSU, with “DC to H trunk lines” switch ON)
to H trunk lines switch” position
(see Figure 1, pos.21)
OFF
ON
Warnings and notes
Recommended as rst choice.
WARNING: BEFORE CONNECTION ALWAYS CHECK DC POWER TO H TRUNK LINES SWITCH (see Figure 1, pos.17). IT MUST BE IN POSITION "OFF"! Note: All trunk lines preserve DC bypassing.
WARNING: Don’t overload PSU via H trunk
lines – check total system power consumption of multiswich and from H trunk lines (including all other equipment connected). Check all other system equipment connected to H lines if it can accept 20 V. SERIOUS
DAMAGE OF IT CAN OCCUR!
2
Page 3
3. Multiswich is powered from H trunk lines:
- building new SCR/dSCR system (18 V - 20 V)
ON
WARNING: Don’t exceed the current capability of system power supply.
SERIOUS DAMAGE CAN OCCUR IF OVERLOADED!
- upgrading old legacy systems (15 V - 18 V)
4. Multiswich is powered from Legacy/ dSCR (subscriber) outputs
(see Figure 1, pos. 11-14). Each dSCR output circuit is individually powered directly from STB’s or from dSCR power inserter (with 22 kHz bypass).
OFF
WARNING: MULTISWITCH WILL DRAW CURRENT AND POWER FROM PAIR OUTPUT WITH HIGHER VOLTAGE! If STB’s connected to Legacy/dSCR outputs
can’t supply su󰀩cient power for it’s own output – dSCR
power inserter with 20 V PSU should be used (one per out put of pair A or B). WARNING: Don’t exceed the current capability of power inserter and dSCR outputs (800mA max.). SERIOUS DAM
-
-
AGE CAN OCCUR IF OVERLOADED! Note: Terr. TV amplier can be powered from H trunk lines
(15-20 V) to minimize current consumption from STB and keep Terr. TV operation when all STBs are OFF.
Power ON indication LED (see Figure 1, pos. 16) glows Green at any of the 4 powering modes. Then switch on receiver(s). The multiswitch will begin the process of auto-detecting which type(s) of receiver connected.
All subscriber outputs are congured to connect legacy STB (supports +13V / +18V/22 kHz signals), but it switches to
dynamic mode SCR/dSCR if receives a DiSEqC command according EN50494/EN50607.
Set the highest frequency UB for STB located nearest to the multiswitch and lowest frequency for STB farthest to the
multiswitch. If you install less than max. possible STB’s use lowest frequencies rst.
Disconnect RF cables or STB‘s from necessary outputs to reset to legacy / Start mode.
PIN code
All User Bands (UB) are protected by PIN Code to prevent the set of UB from being used/disturbed by another user (see Table 2).
Default settings
1. SAT IF inputs are congured to use Ku-band Quattro LNB (SAT A, LNB Lo=9750/10600 MHz).
2. All outputs are congured to connect Legacy STB (+13 V/+18 V/22 kHz), but it switches to Dynamic mode SCR/dSCR
if receives a DiSEqC command according EN50494/EN50607. Output User Bands (UB) are the same in all subscriber outputs (see Table 2). ). All user bands are turn o󰀨 (Start mode).
3. PIN Codes (see Table 2 and see chapter "Conguration").
4. Only one UB plan is set depended of delivery region, if you need another plan see chapter "Conguration" or contact TERRA UAB.
5. DC power to H trunk lines switch (see Figure 1, pos. 17) in position “OFF”.
Table 2
Marking: v.0 Marking: v.1 Marking: v.2
User
Band
(UB)
UB0 46 1210 1210
UB1 1 40 1210 1210 40 1210 no 46 1420 1420
UB2 2 40 1420 1420 40 1420 no 46 1680 1680
UB3 3 40 1680 1680 40 1680 no 46 2040 2040
UB4 4 40 2040 2040 40 2040 no 46 1006 1006
UB5 5 40 1284 1284 40 no 985 46 1057 1057
UB6 6 40 1516 1516 40 no 1050 46 1108 1108
UB7 7 40 1632 1632 40 no 1115 46 1159 1159
UB8 8 40 1748 1748 40 no 1275 46 no 1261
UB9 9 40 no 970 40 no 1340 46 no 1312
UB10 10 40 no 1010 40 no 1485 46 no 1363
UB11 11 40 no 1050 40 no 1550 46 no 1471
UB12 12 40 no 1090 40 no 1615 46 no 1522
UB13 13 40 no 1130 40 no 1745 46 no 1573
UB14 14 40 no 1170 40 no 1810 46 no 1624
UB15 15 40 no 1330 40 no 1875 46 no 1731
UB16 16 40 no 1370 40 no 1940
PIN
Code
Bandwidth,
MHz
Central frequency,
MHz
EN50494 EN50607 EN50494 EN50607 EN50494 EN50607
Bandwidth,
MHz
Central frequency,
MHz
Bandwidth,
MHz
Central frequency,
MHz
Conguration
The default setting of the device can be changed using dedicated programmer and software.
These multiswitches can be congured up to 32 User Bands (UB) per pair outputs (SRM543 total 64 UB) for use with
STB’s supporting DiSEqC commands according to standards EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 V/22 kHz) commands. Default settings Dynamic mode can be changed to Static mode.
PC Windows software can be free downloaded from www.terraelectronics.com.
3
Page 4
Output conguration must be the same per pair of outputs, but can be di󰀨erent in others pairs. Each pair of outputs is
congured separately. Pay attention to the numbering of outputs.
Some possible outputs pair congurations shown in Table 3:
Table 3
Output 1 Output 2
8 SCR/dSCR UB + up to 24 dSCR UB + Terrestrial TV
Legacy + Terrestrial TV
8 SCR/dSCR UB + up to 24 dSCR UB, PIN protected + Terrestrial TV Legacy + Terrestrial TV
Static mode (up to 32 converted transponders) + Terrestrial TV Legacy + Terrestrial TV
8 SCR/dSCR UB + Static mode (24 converted transponders) + Terrestrial TV Legacy + Terrestrial TV
See programmer user manual for more information.
Recommended accessories
1. Power supply PS202F
2. Power inserter PI012
3. Multiswitch programmer PC102W
Technical characteristics
Type SRM523 SRM543
Frequency range SAT IF 950-2150 MHz
Terr. TV 47-862 MHz
Number of trunk inputs SAT IF 4 & outputs Terr. TV 1 Number of tap outputs 2 (1 pair) 4 (2 pairs)
Return loss / impedance > 10 dB / 75
Input level SAT IF 60-95 dBµV Terr. TV IMD3=60 dB 96 dBµV max.
Terr.TV noise gure 6 dB
Tap output user bands (dSCR mode) congurable 32 max. per pair outputs with combined DTT user band bandwidth (dSCR mode) congurable 20-60 MHz dSCR mode output level,
AGC controlled legacy mode output level, typical 78 dBµV
Terr. TV gain 8 dB 4 dB Terr. TV output level IMD3=60 dB 104 dBµV max. IMD3=60 dB 100 dBµV max.
Trunk output loss SAT IF < 3.0 dB Terr. TV < 1.0 dB DC pass through SAT IF 2 A max., 1 A max. through one line
trunk lines Terr. TV 250 mA max. Decoupling SAT IF inputs/SAT IF inputs > 30 dB
SAT IF inputs/tap outputs > 30 dB SAT IF/ Terr. TV > 25 dB Current from DC input* 20 V 270 mA max. 20 V 510 mA max. consumption from H trunk lines 15 V 370 mA; 18 V 310 mA; 15 V 700 mA; 18 V 580 mA;
20 V 270 mA 20 V 510 mA max.
Terr.TV amplier 15-20 V 40 mA max.
from STB legacy mode 13 V 270 mA max., 18 V 240 mA max.
dSCR mode 13 V 370 mA max. legacy+dSCR mode 13 V 410 mA max., 18 V 310 mA max.
Current pass from DC input to H trunk lines, switchable 20 V 1.73 A max. 20 V 1.49 A max. Operating temperature range -20 Dimensions 134x135x30 mm 134x135x30 mm
Weight (packed) 0.42 kg 0.44 kg
84 dBµV
o
÷ + 50o C
* without external DC feeding
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 E-mail: sales@terraelectronics.com, http://www.terraelectronics.com