Termofor INDIGIRKA-2 Installation And Operation Owner's Manual

1
INDIGIRKA-2
ELECTRICITY GENERATING HEATING AND COOKING WOOD BURNING STOVE
WARNING FOR YOUR SAFETY:
1. Read the installation, operation, and maintenance instructions thoroughly before installing or operating this equipment.
2. Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.
3. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
4. For Outdoor Use Only
Warmth comes from Siberia!
INSTALLATION AND OPERATION OWNER’S MANUAL
Made in Russia
2
Dear Customer!
Termofor, one of the leading heating and sauna wood stove manufacturers in Russia, congratulates you on your purchase and wishes that you get maximum satisfaction from your wood stove.
In this manual we provide you with technical advice regarding installation, operation and maintenance of the chosen model you have bought. Please read carefully before operating your appliance and keep the manual for future reference.
Thank you, Termofor.
Contact us: P.O.Box 12
Bolschevistskaya str., 131
Novosibirsk 630083 Russian Federation www.termofor.ru/eng office@termofor.ru
Table of Contents:
IMPORTANT SAFEGUARDS ...................................................................................................................................... 3
CHARACTERISTIC FEATURES ................................................................................................................................ 4
SPECIFICATIONS AND DIMENSIONS .................................................................................................................... 5
DESCRIPTION AND DESIGN ..................................................................................................................................... 7
CLEARANCES ............................................................................................................................................................... 8
INSTALLATION .......................................................................................................................................................... 10
OPERATION ................................................................................................................................................................ 12
OPERATION IN ELECTRICITY GENERATING MODE .................................................................................... 13
MAINTENANCE .......................................................................................................................................................... 14
MALFUNCTIONS ........................................................................................................................................................ 15
BASICS OF THERMOELECTRICITY .................................................................................................................... 15
PACKAGING AND TRANSPORTATION ............................................................................................................... 16
LIMITED FIVE-YEAR WARRANTY ....................................................................................................................... 18
This document is protected by copyright law. Full or partial reproduction of the contents of this document is prohibited without prior noticing and obtaining permission from Termofor.
Company Termofor reserves the right to make insufficient alterations in the design of the stove, which do not impair its consumer properties, without updating the accompanying documentation.
3
IMPORTANT SAFEGUARDS
DANGER: Failure to mind the dangers, follow warnings and cautions in this manual may result in
serious bodily injury or death, or in a fire or an explosion causing damage to property.
This stove is primarily for outdoor use. Do not use the stove for permanent indoor heating or cooking. Do not use the stove in rooms intended for sleeping or permanent residence. Do not use in or on boats or recreational vehicles. Do not use on wooden decks, wooden furniture or other combustible surfaces. Do not use in an explosive atmosphere. Do not store or use gasoline or other flammable liquids or vapors within 25 feet (7.5 m) of this
appliance.
Keep the surrounding area clear and free from combustible materials such as firewood, wet clothing,
gasoline and other flammable vapors and liquids, etc.
Do not alter stove in any manner. Do not use the stove unless it is completely assembled and all components are securely fastened and
tightened.
This stove is designed to burn natural wood. It is strictly forbidden to use coal and coal briquettes. Do not start a fire with vapors, chemicals or fluids such as gasoline, engine oil, alcohol, etc. Do not touch the stove or its parts while they are hot and educate all children of the danger of a high-
temperature appliance. Children and pets should be supervised when they are in the area close to the burning stove or in the same room.
Never touch cooking surface, ash drawer and other components to check their temperature. Do not touch metal parts of the stove until it has completely cooled to avoid burns, unless you are
wearing protective gear (pot holders, gloves, mittens, etc.).
Wear protective gloves when adding fuel to retain desired heat mode. Do not let the stove become hot enough for any part to glow red. Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and
damage.
Do not connect to the electrical clamp outlets electrical devices with power consumption over 50W.
Such connection may damage the electricity generating components.
When connecting electrical devices to the external outlets make sure that polarity of terminals is
correct.
4
CHARACTERISTIC FEATURES
The electricity generating heating and cooking wood burning stove INDIGIRKA-2” (further stove or INDIGIRKA-2) is designed for prolonged heating, generation of the electric power, cooking and food warming. The stove is very useful especially in emergency situations (wildlife, low temperatures, disasters etc.) and is interesting for fishermen, hunters, tourist, travelers, rescuers and other people, who will need temporarily heat and energy resources.
This stove can be used at the outside temperature from -30C(-22F) up to 40C (104F). The appliance does not contain any hazardous and toxic substances that can impair men’s health or the
environment.
Features and advantages The small weight and dimensions allow transportation of the stove and installation in any accessible
place.
During the process of heating or cooking, which are the primary purposes of the stove, it generates the
direct current of 12 volts and power not less than 50 watts
The electricity generators enter stable operation mode 12 – 15 minutes after fire starts. During burning
thermoelectric generators produce electricity, which is transferred to the control block and then to the external clamp outlets.
The thermoelectric generators supply enough energy to light 2-3 energy-efficient bulbs, charge a
notebook, a cell phone, an iPod or Reader, a camera or watch a portable TV or radio.
It’s not very much – but in emergency situations it will allow you to use most portable devices you have
used before. You may want to keep it safe in your backyard, just in case.
The project was developed by Termofor in association with “Kryotherm” (a company based in Saint-
Petersburg, Russia). The same types of generators made by our partner are used in the defense industries, space technologies and other high-tech spheres.
The cooking surface allows cooking on the surface or even over an open fire in pans of various sizes.
You can load fuel from the top too, or clean the upper part of the stove if needed.
This stove is designed to burn natural wood. Higher efficiencies and lower emissions generally result
from burning air dried seasoned hardwoods, as compared to softwoods, green or freshly cut hardwoods. It is possible to temporarily burn pellets, wood briquettes, charcoal. It is strictly forbidden to use coal as fuel.
The primary air, needed for burning is fed through the small gate in the ash drawer and the grate to the
fuel.
The small gate in the ash drawer is used to regulate air feed, providing a clean burn. Ash falls through the grate into the ash drawer. Once the ash drawer is full empty the drawer outside to
keep things clean. It is safe to pull out the ash drawer while the stove is burning.
Combustion gases are directed through the flue of 3.15” (80 mm) in diameter, located at the top of the
stove.
5
SPECIFICATIONS AND DIMENSIONS
Specifications are given in Table 1. External dimensions are given in the Picture 1.
Heated space, up to
1700 cu.ft. ( 50 cu.m)
Max power
13700 BTU/h (4 kW)
Exterior Dimensions
Width
21.3” (540 mm)
Depth
16.8” (427 mm)
Height
25.7” (652 mm)
Weight
119 lb. (54 kg)
Door size (diameter)
7” (178 mm)
Firebox volume
1.45 cu. ft. (41 l)
Fuel capacity
1 cu. ft. (30 l)
Length of logs, maximum
14” (36 cm)
Flue size
3.15” (80 mm)
Flue height, minimum
10 ft (3 m)
Number of flue pipes (included)
9 pcs
Area of heating surface
6.5 sq.ft. (0.6 sq.m.)
Output power
50W
Output voltage
12V
Table 1.Specifications of the Electricity generating, heating and cooking wood burning stove INDIGIRKA-
2.
6
Picture 1.External dimensions of the stove INDIGIRKA-2.
Loading...