Termodinamik DEK SERIES, DEK 6, DEK 12, DEK 9, DEK 24 Installation And Usage Manual

...
H E A T I N G S Y S T E M S
DEK SERIES ELECTRICAL BOILER
INSTALLATION AND USAGE MANUAL
H E A T I N G S Y S T E M S
H E A T I N G S Y S T E M S
ENTRY
Termodinamik digital electric boiler provides economic, comfortable, unproblematic and
environmentally solutions for heating and water heat systems.
Termodinamik digital electrical boiler is heating equipment for apartments (flats) and small
houses. It is economic to own and operate, runs trouble-free.
The obvious advantages are;
The one and only fuel is the electricity.
Resistances go online one by one to minimize electricity usage. Takes very little space and easy to
assembly on the wall.
One unit answers your need to heat and hot water. Temperature can be adjusted to different
settings. Accident risk is almost nonexistent.
Has a safety valve opens at 2.5 / 3 bar.
Has a timer for comfort settings in a daily cycle. Has limit thermostat at 90°C for safety.
No flue gas, no chimney connection, quiet operation and safe. When voltage leakage is detected
system shuts its self off automatically.
Electricity to resistances is automatically shut off when water pressure decreases. Digital controls
for ultimate comfort.
Form No: 14KL.0.14.1.1 REV011601
H E A T I N G S Y S T E M S
WARNING
Assembly of an el ectrical equipment must be
performed by qualifie d and certified electrician (DIN VDE 0105).
Gener al rules of thu mb related to working with
electricity must be fo llo we d. For instance: Electricity must be shut down befo re any work begins.
WARNING
If instruction s in this manual are not
followed, a serious fire and/or explosion may ocur, resulting with personal injury, property damage, even death.
WARNING
:
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for assistance or additional information. Consult a qualified installer, authorized service, or the electric utility.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer, service agency or the electric utility.
H E A T I N G S Y S T E M S
ENTRY GENERAL
....................................................................................................... 3
1 INTRODUCTION
..................................................................................... ...4
2 GENERAL FEATURES
......................................................................................
5-6
3 COMPONENTS (6-9-12 kW)
...................................................................... 7
4 COMPONENTS (18-24-30-36 kW)
............................................................. 8
5 ASSEMBLY & STARTUP
................................................................................... 9
6 MOUNTING ON THE WALL
.................................................................... 10
7 CONNECTIONS OF THE BOILER
............................................................. 11
8 SYSTEM CONNECTION DETAILS
............................................................ 12
9 ELECTRICAL CONNECTIONS
.............................................................
13-15
10 WATER FILLING THE SYSTEM
............................................................... 16
11 THE FIRST INSTALLATION OF THE BOILER
............................................ 17
12 SAFETY
................................................................................................. 17
13 TERMODINAMIK DIGITAL ELECTRICAL BOILER TECHNICAL DATA…….18 14 DIGITAL BOARD USER’S GUIDE
.......................................................... 19
141. GENERAL VIEW OF THE BOARD
................................................. 19
142. BUTTONS
............................................................................. 19-20
143. DISPLAY AND INDICATORS
............................................................. 21
144. SET VALUE ENTERANCE
............................................................. 21
145. TURN ON / TURN OF
................................................................ 22
146. TIME SETTINGS.
........................................................................ 22
147. CHILDREN LOCK
........................................................................ 22
148. ROOM THERMOSTAT
..................................................................... 22
149. TIMER MENU
............................................................................ 23
1410. TIMER OPERATING
.................................................................. 25
1411. USER’S PARAMETERS
............................................................... 25
1412. ERRORS / NOTICES
................................................................. 26
CONTENT
H E A T I N G S Y S T E M S
3
1.
Electrical boiler is never worked without water. Do it only when absolutely necessary
and do it only under full supervision of service person and do it fast. When out of service
for long period of time (such as summer season), do not empty the water.
2.
Use only warm water and soap to clean external panels.
3.
Compliance with instructions in this user manual keeps your boiler efficient and
running smoothly.
4.
Termodinamik Electrical Boiler has been delivered to you all checked and adjusted at
the factory, ready to run. The service technician who will come for the start-up will
perform fine adjustments and inform you. Please do not interfere with adjustments without
the knowledge of service technician.
5.
Never run the boiler without water. You will cause serious damage to resistance.
6.
We recommend you read your manual carefully and keep it at a safe place for referral
later.
Important:
All supply equipment, installation, approvals, permits, inspections, etc. are the responsibility of
the owner of this electrical boiler. Consult your local authorities for regulations specific to your area.
TERMODINAMIK DIGITAL ELECTRICAL BOILER OPERATION MANUAL
This manual belongs to user and should be kept after assembly for referral later.
GENERAL
H E A T I N G S Y S T E M S
4
2 GENERAL FEATURES
Your electrical boiler has been subjected to various safety tests during manufacturing
processes.
Your electrical boiler has been insulated all around with aluminum foiled fiberglass insulation
and energy losses have been minimized. Surface of internal sheet metal chassis parts are
protected with high quality primer paint, external surfaces are protected with electrostatic
epoxy-polyester powder paint against the corrosion.
Closed expansion tank is a standard item with your boiler. It maintains safety of your water
systems against the pressure variations.
When the user sees that the pressure drops below 1 bar, must interfere personally and fill
water into the system. Your boiler has a water pressure switch for safety to shut off the entire
system in case of water pressure drop to 0,6 bars (lack of water) to prevent parching of
resistances. (Boiler is now in off position and water must be added and on button must be
pressed to restart).
The water heated in your boiler passes through plat e heat exchanger before goes to
radiators and heats your domestic use water to provide you with hot water.
Your boiler has been checked at the factory and ready to run. Please read this user manual
first, before using your boiler and keep it at a safe place for later referral.
Your boiler will serve you for a long time with maximum efficiency as long as
recommendations here followed.
1. INTRODUCTION
FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL MAY RESULT IN DEATH,
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. THOROUGHLY READ ALL
INSTRUCTIONS BEFORE YOU ATTEMPT TO INSTALL, OPERATE OR MAINTAIN THIS BOILER.
5
H E A T I N G S Y S T E M S
2. GENERAL FEATURES
QUITE: It is electrical, by nature it is quite.
SAFE: Your boiler has a water pressure switch for safety to shut off the entire system in
case of water pressure drop to 0.6 bar. (Boiler is now in off position and water must be
added and on button must be pressed to restart).
Thermostat is set to 80oC max. When this is reached electrical current to resistances is shut off. If this thermostat malfunctions, there is a limit thermostat set for 90°C.
Digital manometer displays water pressure all the time. If pressure reaches 2.5 / 3 bar safety
valve opens, pressure is released and some water discharged.
ECONOMY: High quality subcomponents enable use of electricity as a fuel with highest possible efficiency.
Provides independent heat. Heat as much as you want, when you want. Pay as much you heat.
Fully programmable and has timer for your automatic setting.
One unit provides you with heat & hot water.
Electronic control card is modulated for economy.
EASY TO USE: One touch button safe & easy operation.
HIGH OUTPUT: Electricity as a fuel has high efficiency with very minimal loss. Therefore
your boiler has naturally high efficiency.
ENVIRONMENTALLY FRIENDLY: The fuel is electric. Therefore, no flue gas, no chimney,
no dirt of carbon-based fuels create.
WIDE SPREAD SERVICE NETWORK: Termodinamik has wide spread established service
network all over Turkey, ready to respond when you need.
LONG LASTING: Your boiler is protected against effects of corrosion.
WARRANTY: Your boiler has 2 years warranty against the defects resulting from
manufacturing. Defected parts are replaced with new ones.
H E A T I N G S Y S T E M S
PACKING
: External surface your boiler is painted sheet metal with protective film to prevent
stretches during handling and assembly. Please peel off the film before start-up. Your boiler
has been packed in a corrugated box for safe transport.
6
H E A T I N G S Y S T E M S
7
3. BOILER COMPONENTS (6-9-12 kW MODELS)
1 3 WAY VALVE HYDRO BLOCK (IN-OUT)
2 PLATE HEAT EXCHANGER
3 PUMP BODY
4 PUMP COVER
5 3 WAY VALVE MOTOR
6 WATER PRESSURE SWITCH
7 PUMP RING
8 PUMP MOUNTING PLATE
9 EXPANSION TANK (7 Liters)
10 COPPER PIPE (PUMP BOILER IN)
11 HEATING RESISTANCE
12 RESISTANCE GASKET
13 RESISTANCE PROTECTION PLASTIC COVER
14 THERMOCOUPLE PIPE
15
EXPANSION TANK HOSE
16 DIGITAL PANEL
17
AUTOMATIC SAFETY VALVE
18 RELAY BOX
22 AUTOMATIC AIR PURGER
23 MANUAL AIR PURGER
24
TERMODINAMIK LABEL
25
PRODUCT LABEL
26 INNER TANK BODY
27
EXTERNAL BODY (CASING)
28
BOILER EXIT PIPE
Loading...