IO-752:2018/EN 05.12.2018
2
1. INTRODUCTION
This instruction manual describes instantaneous gas
water heaters, adapted for installations with one or more
tap (eg. shower, sink etc.).
All drawings, specifications and another information
included in this instruction are based on the up-to-date
data of the product, available at the moment of issuing
this instruction.
The manufacturer reserves the right to make changes
in gas water heater design, without indicating them in
the instruction, as far as the modifications do not have
influence on the operational and technical features of
the product.
Long-term operation of the product and its reliability
most depend on proper installation and use as well as
performing the maintenance in due time and in proper
way.
1.1. IMPORTANT TIPS
Read this before any installation works or use.
• Gas appliances, that are permitted for use and
signed with symbol are safe if they are being
used appropriately and complying with specific rules
of installation and use.
• This installation guide and user’s manual is an
integral part of the water heater unit and as such it
should be kept at hand, and be studied carefully
throughout, as it contains all the necessary
information and precautions that need to be
observed to ensure the safety of installation, usage
and maintenance of this unit. In case of transferring
the appliance to another user, this manual should be
also attached.
• The installation and regulation works must be
performed by an authorised company.
• A room that the unit will be installed in must provide:
- flue conducting, through a pipe connected to an
individual flue with a proper draught,
- efficient supply - exhaust ventilation – in
accordance with this instruction manual and the
local regulations.
Non-observance of this requirements may be
unsafe for a user and may also cause the product
damage (i.e. example water system freezing).
• The unit may be assembled and started up only after
all the other construction and installation works in its
designated room are finished. It is strictly forbidden
to assemble and use the unit in rooms where
construction or other installation works are still under
way.
• Gas and water systems should be equipped with
appropriate filters, which are not included with the
unit.
• The water heater can be operated only by adults.
• Do not perform any repairs or alterations to the water
heater on your own.
• It is strictly forbidden to make any modifications that
could reduce the clearance of air-intake holes
(covering, blanking off etc.) or uptake and flue ducts
in a room and in the appliance.
• Do not keep any containers with inflammable,
aggressive or strongly corrosive chemicals close to
the water heater.
• It is forbidden to keep or dry clothes or other
inflammable objects on or nearby the appliance and
flue ducts.
• The service and maintenance operations of the
water heater can be only performed by an authorised
company.
• Effects of not - observance the instructions included
in this document by gas engineers or users are
excluded from the warranty coverage.
• After exploitation of the boiler, disassembled product
transfer to a specialized unit for utilization.
The manufacturer will not be liable for any
damage or malfunction of the product caused
by faulty installation or use, as the results of
non-observance the manufacturer instructions
and any relevant, official regulations.
Before you start up the water heater,
concerning for your safety, make sure if:
1. Permanent air supply that is necessary for
gas combustion is provided,
2. The appliance has been connected to an
individual and efficient chimney duct,
3. The gravitational ventilation duct is not
choked.
If you smell a gas:
1. Do not use electric switches likely to
cause a spark.
2. Open the door and windows.
3. Shut down the main gas valve.
4. Contact the gas emergency service.
5. If the gas escapes from an untaught valve
of a gas cylinder, shut down the valve,
disconnect the cylinder and take it outside
the building.
6. If the gas escaping from a leaky valve on
the cylinder catches fire, throw a wet
blanket on the cylinder in order to
extinguish the fire, and then pour water on
it in order to cooling down the cylinder and
make possible to turn off the valve.
In a case of breakdown:
1. Turn off the gas supplying valve.
2. Turn off the water supply if there is a risk
of flooding.
3. If there is a risk of water heater freezing,
drain out the water from it.
If you smell fumes:
1. Switch off the heater by turning off the hot
water tap or shut down the gas valve of
water heater.
2. Open the door and windows.
3. After airing the room, switch on the heater
for a while and check if the gas smell
disappeared. If not, contact the fitter or the
chimney service in order to check the
exhaust system efficiency.