TERMET TERMAQ Series, TERMAQ AQUA-POWER ECO GH-19-02, TERMAQ ELECTRONIC ECO GE-19-02 Installation And Operation Manual

1450
INSTALLATION AND OPERATION MANUAL
Instantaneous gas water heater
DEAR CUSTOMER,
Congratulations on choosing the termet product.
You have purchased a modern, economical and environment-friendly
product that complies with high EU quality standards.
Please take time to get yourself familiarised with this manual, as full
understanding of the product's functions, as well as knowledge of
manufacturer's recommendations is imperative for its smooth,
economical and safe operation.
Please keep this manual handy throughout the whole operational
lifetime of the water heater.
We hope you will be satisfied with our product.
IO-752:2018/EN 05.12.2018
1
CONTENS
1. INTRODUCTION ....................................................................................................................................................... 2
1.1. IMPORTANT TIPS ............................................................................................................................................ 2
2. PRODUCT DESCRIPTION........................................................................................................................................ 3
2.1. Technical features ............................................................................................................................................. 3
2.2. Water heater construction and technical data ................................................................................................... 3
2.2.1. Main components of the water heater ...................................................................................................... 3
2.2.2. Technical data ........................................................................................................................................... 5
2.3 Protection equipment ........................................................................................................................................ 5
3. WATER HEATER INSTALLATION ............................................................................................................................ 5
3.1 Main installation regulations .............................................................................................................................. 6
3.1.1 Removing and installing the front cover ........................................................................................................ 6
3.1.2 Location ......................................................................................................................................................... 6
3.1.3 Ventilation ...................................................................................................................................................... 6
3.1.4 Flue gas offtake system ................................................................................................................................ 6
3.1.5 Gas system ................................................................................................................................................... 7
3.2 Preliminary check-up operations ....................................................................................................................... 7
3.3 Water heater mounting ...................................................................................................................................... 7
3.4 Connecting to the gas supply ............................................................................................................................ 7
3.5 Connecting to the water supply ......................................................................................................................... 7
3.6 Connecting to a flue system .............................................................................................................................. 8
4 WATER HEATER OPERATION ................................................................................................................................ 8
4.1 Preparing the water heater for the first start-up ................................................................................................ 8
4.2 Water heater starting-up ................................................................................................................................... 9
4.3 Water temperature and water flow regulation ................................................................................................... 9
4.4 Water heater switching off ............................................................................................................................... 10
5 ADAPTATION OF THE water HEATER TO COMBUST OTHER TYPES OF GAS ................................................ 10
5.1 Gas consumption values ................................................................................................................................. 10
6 KEEPING IN THE RIGHT TECHNICAL CONDITION ............................................................................................. 10
6.1 Heat exchanger cleaning (removing sediment and scale) .............................................................................. 10
6.2 Burner maintenance ........................................................................................................................................ 11
6.3 Water filter cleaning......................................................................................................................................... 11
6.4 Gas filter cleaning............................................................................................................................................ 11
6.5 Safety system checking .................................................................................................................................. 11
6.5.1 Checking the protections against flue gas outflow into the room ................................................................ 11
6.5.2 Checking the protection against heat exchanger overheating .................................................................... 11
7 DIAGNOSTICS ........................................................................................................................................................ 12
7.1 Igniting system diagnostics ............................................................................................................................. 12
7.2 Igniting system checking ................................................................................................................................. 12
7.3 Checking the coils of differentia pressure valve .............................................................................................. 12
8 DEFECTS - CAUSES AND METHODS OF REMOVING ........................................................................................ 13
IO-752:2018/EN 05.12.2018
2
1. INTRODUCTION
This instruction manual describes instantaneous gas water heaters, adapted for installations with one or more tap (eg. shower, sink etc.). All drawings, specifications and another information included in this instruction are based on the up-to-date data of the product, available at the moment of issuing this instruction. The manufacturer reserves the right to make changes in gas water heater design, without indicating them in the instruction, as far as the modifications do not have influence on the operational and technical features of the product. Long-term operation of the product and its reliability most depend on proper installation and use as well as performing the maintenance in due time and in proper way.
1.1. IMPORTANT TIPS
Read this before any installation works or use.
Gas appliances, that are permitted for use and
signed with symbol are safe if they are being used appropriately and complying with specific rules of installation and use.
This installation guide and user’s manual is an
integral part of the water heater unit and as such it should be kept at hand, and be studied carefully throughout, as it contains all the necessary information and precautions that need to be observed to ensure the safety of installation, usage and maintenance of this unit. In case of transferring the appliance to another user, this manual should be also attached.
The installation and regulation works must be
performed by an authorised company.
A room that the unit will be installed in must provide:
- flue conducting, through a pipe connected to an individual flue with a proper draught,
- efficient supply - exhaust ventilation – in accordance with this instruction manual and the local regulations.
Non-observance of this requirements may be unsafe for a user and may also cause the product damage (i.e. example water system freezing).
The unit may be assembled and started up only after
all the other construction and installation works in its designated room are finished. It is strictly forbidden to assemble and use the unit in rooms where construction or other installation works are still under way.
Gas and water systems should be equipped with
appropriate filters, which are not included with the unit.
The water heater can be operated only by adults.
Do not perform any repairs or alterations to the water
heater on your own.
It is strictly forbidden to make any modifications that
could reduce the clearance of air-intake holes (covering, blanking off etc.) or uptake and flue ducts in a room and in the appliance.
Do not keep any containers with inflammable,
aggressive or strongly corrosive chemicals close to the water heater.
It is forbidden to keep or dry clothes or other
inflammable objects on or nearby the appliance and flue ducts.
The service and maintenance operations of the
water heater can be only performed by an authorised company.
Effects of not - observance the instructions included
in this document by gas engineers or users are excluded from the warranty coverage.
After exploitation of the boiler, disassembled product
transfer to a specialized unit for utilization.
The manufacturer will not be liable for any damage or malfunction of the product caused by faulty installation or use, as the results of non-observance the manufacturer instructions and any relevant, official regulations.
Before you start up the water heater, concerning for your safety, make sure if:
1. Permanent air supply that is necessary for gas combustion is provided,
2. The appliance has been connected to an individual and efficient chimney duct,
3. The gravitational ventilation duct is not choked.
If you smell a gas:
1. Do not use electric switches likely to cause a spark.
2. Open the door and windows.
3. Shut down the main gas valve.
4. Contact the gas emergency service.
5. If the gas escapes from an untaught valve of a gas cylinder, shut down the valve, disconnect the cylinder and take it outside the building.
6. If the gas escaping from a leaky valve on the cylinder catches fire, throw a wet blanket on the cylinder in order to extinguish the fire, and then pour water on it in order to cooling down the cylinder and make possible to turn off the valve.
In a case of breakdown:
1. Turn off the gas supplying valve.
2. Turn off the water supply if there is a risk of flooding.
3. If there is a risk of water heater freezing, drain out the water from it.
If you smell fumes:
1. Switch off the heater by turning off the hot water tap or shut down the gas valve of water heater.
2. Open the door and windows.
3. After airing the room, switch on the heater for a while and check if the gas smell disappeared. If not, contact the fitter or the chimney service in order to check the exhaust system efficiency.
IO-752:2018/EN 05.12.2018
3
2. PRODUCT DESCRIPTION
2.1. Technical features
Electronic ignition with a ionisation flame control
Lack of chimney draught protection and fumes
leak protection.
Heat exchanger overheating protection.
Proportional power regulation.
Device adapted for water supply system from 20 to
1000 kPa (0,2 to 10,0 bar)
Gas instantaneous water heaters type GE-19-02 and GH-19-02 are manufactured as B
11BS
installation type version, what means that they are intended to be connected to the individual flue chimney. Combustion products are taking out of the room by means of natural draught. The air for the combustion process is being taken directly from the room where the water heaters are installed. Water heaters are equipped with a protection against draught loss in a flue pipe and protection against fumes escape into a room.
The water heaters GE-19-02 and GH-19-02 are equipped with the most recent technical solutions which provide long-lasting, faultless and economic performance and the comfort of use.
The fittings used in the water heaters ensure proportional power regulation, which enables to get constant temperature of outflowing water.
Activation (burner ignition) of the water heater takes place with each opening of the tap. Shutdown takes place after closing the tap.
One of the main advantages of the water heaters is little water flow necessary to start up the appliance (about 3,2 l/min).
Each water heater is destined to combust only one type of gas (for example 3B-G30) and the water heater must be fed only with this type of gas.
The water heater’s type, the group and type of gas, as
well as the service line pressure which the water heater was designed for, are marked on the packaging, in the instruction manual and on the marking plate.
The water heater can be converted to another type of gas only by an Authorized Service Center in accordance with point 5.
2.2. Water heater construction and technical data
2.2.1. Main components
of the water heater
Temperature limiter as protection against overheating of the heat exchanger
Fig. 2.2.1.1 Main components of the water heater
1 Burner 2 Electrode set 3 Water-gas fittings 4 Heat exchanger 5 Draught breaker 6 Spark generator 7 Battery compartment 8 Temperature limiter - protection against flue gas
outflow into the room
6 7
8
5 4
2 1 3
7
IO-752:2018/EN 05.12.2018
4
Fig. 2.2.1.2 Schematic diagram of the water heaters
1. Burner
2. Electrode set
2.1. Igniting electrode
2.2. Ionisation electrode
3. Water-gas fittings
3.1. Gas flow knob
3.2. Temperature selection knob
3.3. Gas filter
3.4. Water supply filter
3.5. Differential pressure valve
3.5.1. Coil I of the differential pressure valve
3.5.2. Coil II of the differential pressure valve
3.6. Regulating screw of the microswitch
3.7. Regulating screw of the little water flow
3.8. Microswitch
4. Heat exchanger
5. Spark generator
6. Battery compartment
7. Hydrogenerator
8. Temperature limiter - protection against flue gas outflow into the room
9. Temperature limiter - protection against the heat exchanger overheating
10. LED display
11. Cable assembly
Loading...