![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg1.png)
LED TV PANEL LIGHT
USER MANUAL
TP02-WW
TP02-CW
KEEP THIS MANUAL FOR FUTURE NEEDS
![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg2.png)
Thank you for purchasing a TERBLY product. You have acquired a powerful
and versatile fixture. We are confident that you will be satisfied with our
excellent products and service. For your own safety, please read this user
manual carefully before installing and operating the device.
CONTENTS
1. SAFETY INSTRUCTIONS 2
2. FEATURES 4
3. FIXTURE OVERVIEW 6
4. DIMENSIONAL DRAWINGS 6
5. INSTALLATION INSTRUCTIONS 7
6. DMX-512 CONTROL CONNECTION 10
7. DMX-512 CONNECTION WITH DMX TERMINAT OR 10
8. DEVICE DMX START ADDRESS SELECTION 11
9. DISPLAY 11
10. DMX PROTOCOL 18
11. CLEANING AND MAINTENANCE 19
12. SERVICE 19
TP02-CW,WW User Manual XM1268/1257-V1.0-NR
1
![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg3.png)
1. SAFETY INSTRUCTIONS
1.1. IMPORTANT SAFETY WARNING
This device has left the factory in perfect condition. In order to maintain this condition and to
ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and
warning notes written in this user manual.
In order to install, operate, and maintain the lighting fixture safely and correctly we suggest that
the installation and operation be carried out by qualified technicians and these instructions be
carefully followed.
CAUTION!
HIGH VOLTAGE. RISK OF SEVERE OR FATAL ELECTRIC SHOCK
CAUTION!
ALWAYS DISCONNECT MAINS SUPPLY BEFORE REMOVING ANY FIXTURE
COVERS
CAUTION!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE. SENSITIVE PERSONS
MAY SUFFER AN EPILEPTIC SHOCK
CAUTION!
NEVER TOUCH THE DEVICE DURING OPERATION! COVERS MAY BE HOT
CAUTION!
KEEP THIS DEVICE AWAY FROM RAIN AND MOISTURE
Important:
Damage caused by the disregard of this user manual is not subject to warranty. The
dealer and manufacturer will not accept liability for any resulting defects or problems.
If the device has been exposed to temperature changes due to environmental conditions,
do not power on immediately. The resulting condensation could damage the device. Leave
the device powered off until it has reached room temperature.
This device falls under protection-class I. Therefore, it is essential that the device be
earthed.
If either lenses or display are damaged (damage may include cracks or gashes in the
material) they must be replaced.
Electrical connections, such as replacing the power plug, must be performed by a
qualified person.
Make sure that the available voltage is not higher than that which is stated at the end of
this manual.
Make sure the power cord is never crushed or damaged by sharp edges. Should the power
cord suffer If this should be the case, replacement of the cable must be done by an
TP02-CW,WW User Manual XM1268/1257-V1.0-NR
2
![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg4.png)
authorized dealer.
If the external flexible power cord of this device is damaged, it shall be exclusively
replaced by the manufacturer or their service agent or a similar qualified person in order
to avoid injury.
When the device is not in use or before performing maintenance, always disconnect the
device from the mains. Only handle the power cord from the plug. Never pull the plug out
of a socket by tugging the power cord.
When powered on for the first time, some smoke or smell may occur. This is caused by
coating on metal parts when heated and is normal. If you are concerned, please contact
your distributor or Terbly.
Do not focus the beam onto flammable surfaces. The minimum distance between the
exiting lens of the device and the illuminated surface must be greater than 0.1 meter.
Please be aware that damage caused by any modifications to the device are not subject to
warranty. Keep away from children and non-professionals.
1.2. GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres,
etc., the device was designed for indoor use only.
This fixture is only allowed to be operated within the maximum alternating current as
stated in the technical specifications in section 2 of this manual.
Handle the device with care, avoid shaking or using force when installing or maintaining
the device.
When choosing the installation location, please make sure that the device is not exposed
to extreme heat, moisture or dust.
If you use the quick lock cam when rigging the device, make sure the quick lock fasteners
are located in the quick lock holes correctly and securely.
Operate the device only after having familiarized yourself with its functions. Do not
permit operation by persons not qualified for operating the device. Most damages are the
result of unprofessional operation.
Please use the original packaging if the device is to be transported.
The applicable temperature for the device is between -10°C to 45°C. Do not use the
device outside of this temperature range.
For safety reasons, please be aware that all modifications to the device are forbidden.
If this device is operated in any way different to the ones described in this manual, the
product may suffer damage and the warranty becomes void. Furthermore, any other
operation may lead to short-circuits, burns, electric shocks etc.
TP02-CW,WW User Manual XM1268/1257-V1.0-NR
3
![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg5.png)
2. FEATURES
Specifications TP02-CW TP02-WW
Light Source Remote Phosphor Remote Phosphor
Color Rendering Index(CRI) 93 97
Color Temperature 5600 K, CT Calibration Available 3200 K, CT Calibration Available
Luminous flux
Dimming 0-100% Linear Dimming 0-100% Linear Dimming
Field Angle
Control DMX 512/ Manual Operation DMX 512/ Manual Operation
IP Rating IP 20 IP 20
Power Consumption 400W (Available for external battery)
Input Voltage AC 100-240V,50/60Hz AC 100-240V,50/60Hz
Net weight
Hanging Type Pole-control Yoke, Manual Rocker Pole-control Yoke, Manual Rocker
18412/10749 lm 15827/9466.6lm
。
103
103
15 kg 15 kg
。
400W (Available for external
battery)
PHOTOMETRIC DATA IMAGE
TP02-CW,WW User Manual XM1268/1257-V1.0-NR
4
![](/html/60/6091/60910f4f74221e4de5b88a9fb60a2876cf62cfde43b653066e68a8609df3913a/bg6.png)
DMX CHANNEL DATA IMAGE
TP02-CW,WW User Manual XM1268/1257-V1.0-NR
5