Thank you for your patronage. We are confident that our excellent products and service can satisfy you. For your own safety, please read this user manual carefully before installing the device. In order to install , operate, and maintain the lighting safety and correctly. We suggest that the installation and operation should be done by the verified technician and follow the instruction strictly.
Every person involved with the installation, operation and maintenance of this device has to:
-be qualified
-follow carefully the instructions of this manual
INTRODUCTION:
Thank you for having chosen this professional moving head. You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find:
1. One XLR connection cable
2. Two omega clamps
3. One safety rope
4. Manual
5. One warranty card and certification
Please check carefully that there is no damage caused by transportation. Should there be any, consult your dealer and don’t install this device.
1. FEATURES
·Lamp: Philips PLATINUM 15R
·3 DMX Channels mode: 21/23/34 channels
·Stand alone operation with Master/Slave function, sound activated via built in microphone.
·Pan and tilt movement: 8 and 16 bit resolution
For smooth and precise motion Movement: Pan: 540°/630°optional, Tilt: 270° Speed of pan/tilt movement adjustable Scan position memory, auto reposition after unexpected movement
·Colors: Basic color wheel with 8 dichroic mirrors, plus white, two direction rainbow effect.
·CMY Variable Color Mixing for Infinite Color Possibilities
·30 CMY and color wheel MACROS and Random CMY
·Rotation gobo: 8 interchangeable, rotating gobos plus open
·Static gobo: 14 static gobos plus open with different speed gobo shaking and gobo indexing
·Prism and prism rotating , with 16 prism macros
·Dimmer intensity from 0%~100%
XM762-V1.0-NR
2
·Focus: motorized focus
·Iris: motorized linear change from 5%~100%
·Stepless frost, 0%~100% linear change frost
·Zoom: 9°~27° linear zoom
·Control board with full color LCD graphic display and touch-keyboard
·Display: Can be changed 180° reverse to fit for different installation position.
·Strobe/shutter: High speed shutter, 0-13 Hz or random strobe
·Wireless receiver pre-installed
·Rechargeable Back up Battery for Display, no need external power supply, enable users to enter
display menu for address setting or access other functions setting.
·Auto-program: 7 pre-built programs can be selected.
·Software-upload by optional accessory via DMX line
2. FIXTURE OVERVIEW
1: Lens 2: Display 3: Wireless indicator 4: DC Switch 5: Microphone 6: Left-button 7: Down-button 8: Right-button 9: Mode/Esc-button 10: Up-button 11: ENTER-button 12: Handle
13: Lamp bracketrear metal panel 14: 3-Pin DMX in 15: 3-Pin DMX out 16: 5-Pin DMX in 17: 5-Pin DMX out 18: Power supply 19: Fuse
XM762-V1.0-NR
3
3. SAFETY INSTRUCTIONS
3.1) Important safety warns
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.
If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device. Leave the device switched off until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be earthed.
If protection screen,lens or ultraviolet screen in the fixture is apparently damaged or is damaged to exceed their own effective degree, such as cracked and gashed, it must be replaced.
The electric connection must carry out by qualified person.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually.
Please don't project the beam onto combustible substances.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
XM762-V1.0-NR
4
Please be aware that damages caused by manual modifications to the device are not subject to warranty. Keep away from children and non-professionals.
3.2) GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the device was designed for indoor use only.
This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual.
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure that the device will serve you for a long time without defects.
Do not shake the device.Avoid brute force when installing or operating the device.
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. Please don't project the beam onto combustible substances.The minimum distance between light-output from the projector and the illuminated surface must be more than
1.5 meter.
If you use the quick lock cam in hanging up the fixture, please make sure the quick lock fasteners turned in the quick lock holes correctly.
Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the device. Most damages are the result of unprofessional operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc.
4. INSTALLATION INSTRUCTIONS
4.1) Installing or replacing the lamp
Only install the lamp with the device unplugged from the mains.
The lamp has to be replaced when it is damaged or deformed.
XM762-V1.0-NR
5
Because of the nature of the extreme heat associated with the Platinum 15R lamp and the tight nature of the internal optical system it is imperative that the lamp be replaced every 1400 hours. This is done to protect the internal optical system as well as prevent accidental lamp explosion, which could lead to hot glass particles falling from the fixture. Failure to change the lamp within 100 hours of operation will result in automatic shut down of the fixture’s electronics.
At 1400 hours the display will begin to flash “Replace The Lamp” and the lamp will flicker for the first five minutes of operation. At this point the lamp has reached the maximum rated life and should be replaced immediately .After the lamp has flickered for about five minutes it should strike normally allowing the fixture to be used temporarily until a replacement lamp can be installed. The fixture will continue to operate for an additional 100 hours, however the “Replace the Lamp” warning will continue to flash in the display . Keep in mind that the flicker protection circuitry will only work for about 100 hours (lamp clock life of 1400-1500 hours). After 1500 hours the fixture will no longer respond to DMX commands and immediately enter a hibernation mode that will electronically discontinue all fixture functionality with the exception of a few menu commands. The fixture will continue to enter hibernation mode until the lamp is replaced and the lamp clock has been reset.
Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the device was designed for.
For the installation, you need one: PLATINUM 15R
Procedures:
1) Unscrew the 3 screws (A, B, C) on the bottom of the housing, holding the plate where the
lamp is underneath. Carefully remove the metal plate.
2) Insert the lamp counter-clockwise 35 degree into the lampholder, then turn clockwise 35
degree to put it into the right position. Attention: please wrap the lamp with the soft cloth that comes with the packing, avoid naked hand contact to the lamp directly.
3) Put the lampholder back position after install the lamp, tighten the screw and complete the
installation.
XM762-V1.0-NR
6
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10 minutes after having turned off the lamp before you can turn it back on again.
Do not operate this device with open cover
4.2) Mounting the device
The applicable temperature for the lighting is between -10°C to 45°C. Do not use the lighting under or above the temperature. The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope.
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time.
These installations have to be approved by a skilled person once a year.
Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
The electric connection must only be carried out by a qualified electrician.
Before mounting make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Connect the fixture to the mains with the power plug.
XM762-V1.0-NR
7
Installation via the Omega holders
a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф13 hole in
the middle of the bracket.
b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the
bottom of the device. Tighten the quick-lock fasteners fully clockwise.
c) Install the second Omega holder. d) Pull the safety-rope through the holes on the bottom of the base and over the trussing system
or a safe fixation spot. Insert the end in the carabine and tighten the safety screw.
Notice: this step is quite important to ensure that the fixture will not drop out by the damage of the clamp.
XM762-V1.0-NR
8
Dimensional Drawings:
XM762-V1.0-NR
9
Layout Drawings:
Mounting points
Be sure this fixture is kept at least 1.5m away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
5. DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below.
XM762-V1.0-NR
10
Address 1 Address 24 Address 47
6. DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain. Please see illustrations below.
7. Projector DMX start address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device. You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually.