Terbly LSP60, LSP40 User Manual

Page 1
LED MOVING HEAD
USER MANUAL
LSP60
KEEP THIS MANUAL FOR FUTURE NEEDS
Page 2
- - XM767-V1.2-NR
Contents
1. Features..........................................................................................................................................................
2. Overview.........................................................................................................................................................
3. SAFETY INSTRUCTIONS..........................................................................................................................
3.1) Important safety warns......................................................................................................................
3.2) GENERAL GUIDELINES................................................................................................................
4. INSTALLATION INSTRUCTIONS............................................................................................................
4.1) Mounting the device...........................................................................................................................
5. DMX-512 control connection........................................................................................................................
6. DMX-512 connection with DMX terminator..............................................................................................
7. Projector DMX start address selection........................................................................................................
8. Control Board............................................................................................................................................ 10
Main Menu Functions........................................................................................................................ 12
9. INSTRUCTIONS ON USE:...................................................................................................................... 19
10. ERROR MESSAGE................................................................................................................................ 19
11. CLEANING AND MAINTENANCE..................................................................................................... 23
12. TECHNICAL SPECIFICATIONS.........................................................................................................23
Page 3
- - XM767-V1.2-NR
Thank you for your patronage. We are confident that our excellent products and service can
satisfy you. For your own safety, please read this user manual carefully before installing the
device. In order to install , operate, and maintain the lighting safety and correctly. We suggest that the
installation and operation should be done by the verified technician and follow the instruction strictly.
Every person involved with the installation, operation and maintenance of this device has to:
-be qualified
-follow carefully the instructions of this manual
INTRODUCTION:
Thank you for having chosen this professional LED moving head. You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find:
1. One XLR connection cable
2. One omega clamps
3. One safety rope
4. Manual
Please check carefully that there is no damage caused by transportation. Should there be any, consult your dealer and don’t install this device.
1. Features
·Extremely Long Life: 100,000 hr and lower power consumption
·2 DMX channel mode: 12/14 channels
·3 operational modes: DMX-512, Master/Slave & Sound Active
·630°or540° pan / 270° tilt (8-bit)
·Strobe effect with 1-13 flashes per second and pulse effect
·Color wheels8dichroic filters plus open, rainbow-effect with adjustable speed in both
directions
·Rotation gobo: 7 interchangeable, rotating gobos plus open
·Prism and prism rotating , with 16 prism macros
·Linear dimmer in precise speed from 0% ~ 100%
·4 digit LED display
·Preset program: 7 built in programs can be called up via DMX controller
·Fan automatically adjust speed according to the LED temperature
·Software-upload by optional accessory via DMX line
Page 4
- - XM767-V1.2-NR
2. Overview
3. SAFETY INSTRUCTIONS
3.1) Important safety warns
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.
If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device. Leave the device switched off until it has reached room temperature.
1) Lens
2) Display
3) Mode/Esc-button
4) Up-button
5) Down-button
6) Enter-button
7) Microphone
8) Handle
9) 3 pin-DMX out
10) 3 pin-DMX in
11) 5 pin-DMX out
12) 5 pin-DMX in
13) Power switch
14) Fuse
15) Power supply
Page 5
- - XM767-V1.2-NR
This device falls under protection-class I. Therefore it is essential that the device be earthed.
The electric connection must carry out by qualified person.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually.
Please don't project the beam onto combustible substances.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
Please be aware that damages caused by manual modifications to the device are not subject to warranty. Keep away from children and non-professionals.
3.2) GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the device was designed for indoor use only.
This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual.
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure that the device will serve you for a long time without defects.
Do not shake the device.Avoid brute force when installing or operating the device.
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. Please don't project the beam onto combustible substances.The minimum distance between light-output from the projector and the illuminated surface must be more than 0,5 meter.
If you use the quick lock cam in hanging up the fixture, please make sure the quick lock fasteners turned in the quick lock holes correctly.
Page 6
- - XM767-V1.2-NR
Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the device. Most damages are the result of unprofessional operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc.
4. INSTALLATION INSTRUCTIONS
4.1) Mounting the device
The applicable temperature for the lighting is between -10°C to 45°C. Do not use the lighting under or above the temperature.
The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope.
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time.
These installations have to be approved by a skilled person once a year.
Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
The electric connection must only be carried out by a qualified electrician.
Before mounting make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
Connect the fixture to the mains with the power plug.
Page 7
- - XM767-V1.2-NR
Installation via the Omega holders
a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф13 hole in
the middle of the bracket.
b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the
bottom of the device. Tighten the quick-lock fasteners fully clockwise.
c) Install the second Omega holder. d) Pull the safety-rope through the holes on the bottom of the base and over the trussing system
or a safe fixation spot. Insert the end in the carabine and tighten the safety screw.
Notice: this step is quite important to ensure that the fixture will not drop out by the damage of the clamp.
Page 8
- - XM767-V1.2-NR
Dimensional Drawings:
Page 9
- - XM767-V1.2-NR
Layout Drawings:
Mounting points
Be sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage
and/or injury in the event the clamp fails.
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
Page 10
- - XM767-V1.2-NR
5. DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below.
6. DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain. Please see illustrations below.
7. Projector DMX start address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device.
Address 29 Address 15 Address 1
Page 11
- - XM767-V1.2-NR
10
You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually. If you set the same address, all the units will start to “listen” to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simultaneously. If you set a different address, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected fixture.
In the case of the move head, which is a 14 channel fixture, you should set the starting address of the first unit to 1, the second unit to 15 (14 + 1), the third to 29 (14 + 15), and so on.
Note:
The modes of DMX 512 data are shown via the display:
DMX OK NO DMX
1. After switching on, the device will automatically detect whether DMX 512 data is received or
not. If the data is received, the display will show "A.001" with the actually set address. If there is no data received at the DMX-input, the display will flash "A001" with the actually set address.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap in the input connector.
It’s necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to ensure proper transmission on the DMX data link.
8. Control Board
There are four keys on the control panel , which could be used to set the address, turn ON/OFF, operating the program and reset.
[Mode/Esc] press this key to enter into edit mode. Press this key under the edit mode if you want
to return to previous menu. it will exit from edit mode 60 seconds after the last keypress
[UP] screen will flash when pressing this key in normal mode, the adress value will increasing.
Keep pressing this key, the address value will increase rapidly. it will exit from flash 60 seconds after the last keypress. Press this key under edit mode, you can choose the function you want from the buttom up in the menu.
[DOWN] screen will flash when pressing this key in normal mode, the adress value
will idecreasing. Keep pressing this key, the address value will decrease rapidly. it will exit from flash 60 seconds after the last keypress. Press this key under edit mode, you can choose the function you want from the top down in the menu.
[ENTER] this key is functionless when in normal mode. Press this key under the edit mode, it
will enter into next menu.
Page 12
- - XM767-V1.2-NR
11
Default settings shaded
VA L U
A001~AXXX (AXXX) DMX address setting
SLAV ON/OFF (SLAV) Slave setting
ADDR
EBOC
ON/OFF
Change DMX address via
external controller
ALON (AU-A) Automatic Run in Stand Alone
AUTO
MAST (AU-M) Automatic Run as Master
ALON (SO-A)
Sound-controlled Run in Stand
Alone
RUN
SOUN
MAST (SO-M) Sound-controlled Run as Master
VA L U D–XX D-00 (DXXX)
Display the DMX 512 value of
each channel
RDIS ON/OFF Reverse display
CLDI ON/OFF Shut off LED display
0 MODE
DISP
LOCK
ON/OFF Key lock
RPAN ON/OFF Pan Reverse
RTI L ON/OFF Tilt Reverse
16BI ON/OFF Switch 16 bit/8 bit
DEGR 630/540 Pan degree select
MIC M-XX M-70 Mic sensitivity
AUTO Clos/Hold/Auto/Audi No DMX Status
FANS AUTO/HIGH/LOW Fan’s mode select
REST Reset
LODA ON/OFF Restore factory settings
HIbE OFF/1-99M 15M Stand by mode
1 SET
VER V-1.0~V-9.9 Software version
LADJ ON/OFF Lamp adjustment
TEST T–01~T–XX Test function of each channel
CODE CXXX (密码 050) Fixture code *code is “C050”
2 ADJU
WHEL
CH01~CHXX XXXX(-128~127) Motor Calibration
MATI 0000~9999(hours) Fixture running time
3 TIME
CLMT
ON/OFF (密码 838) Clear fixture time
STEP S–01 ~S–48 Steps of Program Run
REC. RE.XX Auto Save Scene
C–01~C–XX XXX(0~255) Edit the channels of each scene
TIME T XXX(001~999) Time for each scene
4 EDIT
SC01
~ SC48
CNIN
ON/OFF Edit program via controller
Page 13
- - XM767-V1.2-NR
12
Main Menu Functions
Main functions:
- Main menu 0
1. Press [MODE/ESC] to enter the main menu "MODE" (display flashing)
2. Press [ENTER] and select "ADDR", “RUN” or "DISP" by pressing [UP] or [DOWN] button.
3. Press [ENTER] for selecting the desired sub menu.
- DMX address setting, Slave setting
- DMX address setting
With this function, you can adjust the desired DMX-address via the Control Board.
1. Select “VALU” by pressing [UP] or [DOWN] button.
2. Press [ENTER], adjust the DMX address by pressing [UP] or [DOWN] button.
3. Press [ENTER] to confirm or pressing [MODE/ESC] to return to main menu.
- Slave setting
With this function, you can define the device as slave.
1. Select “SLAV” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] to select “OFF” if you
don’t.
4. Press [ENTER] to confirm or press [MODE/ESC] to return to main menu.
-DMX address setting via controller
With this function, you can adjust the desired DMX-address via an external controller. This function can only be activated when the DMX-value of all other channels is set to "0" on the controller. Select “EBOC” by pressing [UP] or [DOWN]. Press [ENTER], the display shows “ON” or “OFF”. Press [UP] to select “ON” if you wish to enable this function or [DOWN] to select “OFF” if you don’t. Press [MODE/ESC] to confirm. Press [ENTER] in order to return to the main menu. On the controller, set the DMX-value of channel 1 to "7". Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511.
Page 14
- - XM767-V1.2-NR
13
Set the DMX-value of channel 3 to the desired starting address. If you want to set the starting address to 57, set channel 1 to "7", channel 2 to "7" and channel 3 to "57". If you want to set the starting address to 420, set channel 1 to "7", channel 2 to "8" and channel 3 to "164" (256+164=420). Wait for approx. 20 seconds and the unit will carry out a reset. After that, the new starting address is set.
- Program Run, Master setting
With the function "RUN", you can run the internal program. You can set the number of steps under Step. You
can edit the individual scenes under Edit. You can run the individual scenes either automatically (AUTO), i.e. with the adjusted Step-Time or sound-controlled (SOUN). The selection "ALON" means Stand Alone-mode and "MAST" that the device is defined as master.
1. Select "AUTO" or "SOUN" by pressing [UP] or [DOWN] button.
2. Press [ENTER] for selecting the desired extension menu.
3. Select "ALON" or "MAST" by pressing [UP] or [DOWN] button.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Display the DMX-value, Reverse display, Shut off LED display
- Display the DMX 512 value of each channel
With this function you can display the DMX 512 value of each channel.
1. Select "VALU" by pressing [UP] or [DOWN] button.
2. Press [ENTER] to confirm; the display shows“D-00”. In this setting, the DMX-adjustment of every
channel
will be displayed.
3. Press [UP] or [DOWN] button in order to select the desired channel. If you select “D-14” the display will
only
show the DMX-value of the 14
th
channel.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
5. The display shows "D- XX“, ”X” stands for the DMX-value of the selected channel.
- Reverse display
With this function you can rotate the display by 180°.
1. Select "RDIS" by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t; the display will rotate by 180°.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
Page 15
- - XM767-V1.2-NR
14
- Shut off LED display
With this function you can shut off the LED display after 2 minutes.
1. Select "CLDI" by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
——Locked keys the display
With this function you can activate the automatic keylock function. If this function is activated, the keys will be
locked automatically after exiting the edit mode for 15 seconds. keeping press the [[MODE/ESC] key for
3seconds if you want to deactivate the keylock status.
1. Tap the [UP] or [DOWN] button until “LOCK” is displayed and tap the [ENTER] button.
2. Press the [UP] button to select “ON” to activate this function, or “OFF” to deactivate this function. Press [ENTER] to confirm.
3. Press [Mode/Esc] to return to the main menu.
- Main menu 1
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button. to select “SET”.
- Pan Reverse
With this function you can reverse the Pan-movement.
1. Select “RPAN” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Tilt Reverse
With this function you can reverse the Tilt-movement.
1. Select “RTIL” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Switch 16 bit/8 bit
With this function you can switch the device from 16 bit to 8 bit resolution.
1. Select “16BI” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
5. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
Page 16
- - XM767-V1.2-NR
15
- Pan degree select
With this function you can select pan angle 630or 540
0.
1. Select “DEGR” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “630” or “540”.
3. Press [UP] to select “630” or press [DOWN] button to select“540”.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Mic sensitivity
With this function you can adjust the sensitivity of the microphone.
1. Select “MIC” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “M-XX”, “XX” stands for the number from 0 to 70.
3. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
-Automatic Run by no DMX
With this function you can automatic run the device by no DMX.
1. Select “AUTO” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “CLOS”, “HOLD”, “AUTO” or “AUDI”.
3. Press [UP] or [DOWN] button to select “CLOS”, “HOLD”, “AUTO” or “AUDI”, the default is “HOLD”.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Fan’s mode select
With this function you can select the Fan’s mode.
1. Select “FANS” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “HIGH”, “AUTO” or “LOW”.
3. Press [UP] or [DOWN] button to select “HIGH”, “AUTO” or “LOW”, the default is “AUTO”.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Reset
With this function you can reset the device via the Control Board.
1. Select “REST” by pressing [UP] or [DOWN] button.
1. Press [ENTER] to reset or Press [MODE/ESC] to return to the main menu.
- Restore factory settings
With this function you can restore the factory settings of the device. All settings will be set back to the default values (shaded). Any edited scenes will be lost.
1. Select “LODA” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
——“HIBE Stand by mode
The lamp and step motors will be power off if the fixture stay without DMX signal for 15 mins (Factory default).And the fixture will be reset before working once it receive DMX signal again.
1. Select “HIBE” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “15M”.
3. Press [UP] or [DOWN] button , the display shows “01M”,“02M” …. “99M” or “OFF”.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
Page 17
- - XM767-V1.2-NR
16
- Software version
With this function you can display the software version of the device.
1. Select “VER” by pressing [UP] or [DOWN] button.
2. Press [ENTER], The display will show “V-XX”, "XX" stands for the version number, such as the display
may also show,"V-2.0","V-9.9"etc.
3. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Main menu 2
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “ADJU”.
- Lamp adjustment
With this function you can adjust the lamp via the Control Board. The shutter opens and the lamp can be
adjusted. In this mode, the device will not react to any control signal.
1. Select “LADJ” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to select “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Test function of each channel
With this function you can test each channel on its (correct) function.
1. Select “TEST” by pressing [UP] button.
2. Press [ENTER], the display shows “T-XX”, “X” stands for the channel number.
3. The current channel will be tested.
4. Select the desired channel by pressing [UP] or [DOWN] button.
5. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Fixture code and motor fix
1. Select “WHEL” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “CODE” or “CH01-CH30”.
4. Select “CODE” or “CH01-CH30” by pressing [UP] or [DOWN] button.
5. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Main menu 3
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “TIME”.
Page 18
- - XM767-V1.2-NR
17
- Fixture running time
With this function you can display the running time of the device.
1. Select “MATI” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “XXXX”, “X” stands for the number of hours.
3. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Clear fixture time
With this function you can clear the running time of the device.
1. Select “CLMT” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you
don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Main menu 6
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “EDIT”.
- Define the number of steps in Run
With this function you can define the number of steps in the Program Run.
1. Select “STEP” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “S-XX”, “X”
stands for the total amount of steps you want to save,
so you can call up to 48 scenes in “RUN”. For example if the “XX” is 05, it means that “RUN” will run the first 5 scenes you saved in “EDIT”.
3. Press [ENTER] to confirm or Press [MODE/ESC] to
return to the main menu.
-Auto Save With this function you can automatic save the number of steps in the Program Run.
1. Select “REC” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “RE.XX”, “XX”
stands for the scene number in the internal memory of where your scenes from the controller will be stored.
3. Press [ENTER] to confirm or Press [MODE/ESC] to
return to the main menu.
- Editing the channels of the individual scenes
With this function you can edit the program to be called up in Run.
a) Editing via the Control Board
1. Select “SC01” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “SCXX”, “X” stands for the scene no. to be edited.
3. Change the scene no. by pressing [UP] or [DOWN] button.
4. Press [ENTER], the display shows “C-XX”, “XX” stands for the channel no. Such as “C-01”, it means
you are editing channel 1 of the selected scene.
5. Select the channel no. you would like to edit by pressing [UP] or [DOWN] button.
.
.
.
.
Page 19
- - XM767-V1.2-NR
18
6. Press [ENTER] to enter editing for the selected channel, the fixture reacts to your settings. The display
shows the DMX value of the edited channel. the DMX value is XXX, XXX is a algorism number value.
7. Adjust the desired DMX value by pressing [UP] or [DOWN] button.
8. Press [ENTER] in order to edit other channels of this scene.
9. Repeat steps 5-8 until you finish setting all the DMX values for all channels of this scene.
10. Once all the channels completed, the display will flash “TIME”
11. Press [ENTER] to edit the time needed, the display shows “XXX.X” , “X” stands for the time needed to
run the current scene, Adjust the desired time by pressing [UP] or [DOWN] button.
12. Press [ENTER] to save the settings for the scene you are editing, the display will change to the next scene
automatically.
13. Repeat step 3-12 to edit and other scenes, you can edit and save a maximum of 48 scenes.
14. Press [MODE/ESC] to exit. The number of steps can be defined under “STEP” and the scenes can be
called up under “RUN”.
b) Editing via the external controller Call up the first scene in your controller now.
1. Select “SC01” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “SC01”.
3. Press [ENTER], the display shows “C-01”.
4. Select "CNIN" by pressing [UP] or [DOWN] button.
5. Press [ENTER], the display shows "OFF"
.
6. Press [UP] or [DOWN] button .the display shows "ON".
7. Press [ENTER], the display shows "SC02". You successfully downloaded the first scene.
8. Adjust the Step-time as described above under point 12.
9. Call up the second scene in your controller now.
10. Repeat steps 5-11 until all desired scenes are downloaded.
11. Press [MODE/ESC] to exit. The number of steps can be defined under “STEP” and the scenes can be
called up under “RUN”.
Page 20
- - XM767-V1.2-NR
19
9. INSTRUCTIONS ON USE:
DMX channel´s functions and their values (14 DMX channels): Mode/Channel Value Function St Ba Ex
PAN Movement 8bit
5 5
0-255 Pan Movement By 540/630
Pan Fine 16bit
13
0-255 Fine control of Pan movement
TILT Movement 8bit
6 6
0-255 Tilt Movement By 270
Tilt Fine 16bit
14
0-255 Fine control of Tilt movement
Color Wheel
0-14 Open / white
15-29 Color1
30-44 Color2
45-59 Color3
60-74 Color4
75-89 Color5
90-104 Color6
105-119 Color7
120-127 Color8
128-189 Forwards rainbow effect from fast to slow
190-193 No rotation
1 1
194-255 Backwards rainbow effect from slow to fast
Rotating gobos, cont. rotation
0-9 Open
10-19 Rot. gobo 1
20-29 Rot. gobo 2
30-39 Rot. gobo 3
40-49 Rot. gobo 4
50-59 Rot. gobo 5
60-69 Rot. gobo 6
70-79 Rot. gobo 7
80-95 Rot. gobo 1 shake
96-111 Rot. gobo 2 shake
112-127 Rot. gobo 3 shake
128-143 Rot. gobo 4 shake
144-159 Rot. gobo 5 shake
160-175 Rot. gobo 6 shake
2 2
176-191 Rot. gobo 7 shake
Page 21
- - XM767-V1.2-NR
20
192-255 Rot. gobo wheel cont. rotation slow to fast
Rotating gobo index, rotating gobo rotation
0-127 Gobo indexing
128-189 Forwards gobo rotation from fast to slow
190-193 No rotation
3 3
194-255 Backwards gobo rotation from slow to fast
Rotating prism, Prism / Gobo macros:
0-31 open
32-63 3 facet prism
64-95 trapezoid prism
96-127 Frost
128-135 Macro 1
136-143 Macro 2
144-151 Macro 3
152-159 Macro 4
160-167 Macro 5
168-175 Macro 6
176-183 Macro 7
184-191 Macro 8
192-199 Macro 9
200-207 Macro 10
208-215 Macro 11
216-223 Macro 12
224-231 Macro 13
232-239 Macro 14
240-247 Macro 15
8 8
248-255 Macro 16
Rotating prism index, rotating prism rotation :
0-127 Prism indexing
128-189 Forwards prism rotation from fast to slow
190-193 No rotation
9 9
194-255 Backwards prism rotation from slow to fast
Focus :
4 4
0-255 Continuous adjustment from far to near
Shutter, strobe
0-31 Shutter closed
32-63 No function (shutter open)
64-95 Strobe effect slow to fast
10 10
96-127 No function (shutter open)
Page 22
- - XM767-V1.2-NR
21
128-159 Pulse-effect in sequences
160-191 No function (shutter open)
192-223 Random strobe effect slow to fast
224-255 No function (shutter open)
Dimmer (intensity)
11 11
0-255 Intensity 0 to 100%
Speed pan/tilt movement
0-225 max to min speed
226-235 blackout by movement
236-245 blackout by all wheel changing
7 7
246-255 no function
Reset, internal programs
0-19 Color&Gobo change normal
20-29 Color change to any position
30-39 Color&Gobo change to any position
40-59 No function
60-79 No function
80-84 All motor reset
85-87 Scan motor reset
88-90 Colors motor reset
91-93 Gobo motor reset
94-96 No function
97-99 Other motor reset
100-119 Internal program 1
120-139 Internal program 2
140-159 Internal program 3
160-179 Internal program 4
180-199 Internal program 5
200-219 Internal program 6
220-239 Internal program 7
12 12
240-255 Auto program by music
Page 23
- - XM767-V1.2-NR
22
10. ERROR MESSAGE
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is XX” while there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 5, 6 who has the testing sensor for positioning. For example, when the display shows “02 Er”, it means there is some error in channel 2. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “01 Er”, “05 Er”, “06 Er” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain error message after performing reset more than 2 times, only the channels which have errors can not work properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is not allowed.
01Er:
(Color Wheel error) This message will appear after the reset of the fixture if the head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The head is not located in the default position after the reset.
02Er:
(Rotating gobos error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
03Er:
(Gobo rotating error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The zoom is not located in the default position after the reset.
05Er:
(PAN Movement error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB). The color wheel is not located in the default position after the reset.
06Er:
(TILT Movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The yoke is not located in the default position after the reset.
07Er:
(Prism error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The yoke is not located in the default position after the reset.
09Er:
(Focus error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The yoke is not located in the default position after the reset.
Page 24
- - XM767-V1.2-NR
23
11. CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.
4) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakness of the lights due to
accumulation of dust.
2) Clean the fan each week.
3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each
three month, avoiding the excessive lube splashes during the gobo rotating.
4) A detailed electric check by approved electrical engineer each three month, make sure that
the circuit contacts are in good condition, prevent the poor contact of circuit from overheating.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents. There are no serviceable parts inside the device. Please refer to the instructions under “Installation instructions”. Should you need any spare parts, please order genuine parts from your local dealer.
12. TECHNICAL SPECIFICATIONS
Power supply: AC 100-240V~, 50Hz Power consumption: 150W Packing dimensions: 46 x 32.5 x 37cm Net weight: 10.5KGS Gross weight: 12.5 KGS
Remark: errors and omissions for every information given in this manual excepted. All
information is subject to change without prior notice.
Loading...