Teral VFC 408, VFC 808, VFC 708, VFC 8 TH Series, VFC 908 Instruction Manual

Page 1
Instruction Manual
RING BLOW
TH
VFC 8
Series
CAUTION
Read the instruction manual carefully before you install, put into operation and maintain the Ring Blow and handle it properly.
For the sake of safety, never modify the Ring Blow. We take no responsibility for the troubles caused by repairing or modifying the product.
Hand over this instruction manual surely to the end users, who actually install, operate and maintain the Ring Blow.
After having read the instruction manual, keep it at the place, where can be accessed by the persons, who use it.
The specification of the product may be changed without prior notification.
Page 2
Introduction --------------------------------------------------------------------
Thank you for your purchasing of the Ring Blow.
It is required for the Ring Blow for give full play to its performance, for preventing troubles from occurring and for continuing its satisfactory operation for a long period not only to maintain and inspect it after putting it into service but also to handle it properly in every stage after its delivery until its actual operation. This instruction manual illustrates the essential items for handling the Ring Blow.
If you find any question, please inquire of our special agent, dealer or business office about it.
Cautions for safety -----------------------------------------------------------
Read this instruction manual and the other attached documents carefully before you use (install, transport, maintain, inspect etc.) the Ring Blow and then use it properly. Acquire first the machine knowledge, safety information and all caution items and use the machine. Keep this instruction manual at the place, where can be accessed by the persons, who use it.
The ranks for safety items are classified into alarms and cautions and described in this instruction manual.
Alarm
Caution
Even those items marked with situation.
As every item describes serious contents, be sure to keep it always. Furthermore, the following symbols are applied according to necessity in this instruction manual, so that the essential points of indication can be grasped at a glance.
Symbol Meaning Symbol Meaning
Notification of a general prohibition
those items, for which the possibility of human DEATH and
HEAVY INJURY
those items, for which hazardous condition may occur and
MEDIUM HAZARD and SLIGHT INJURY are feared and/or
material damage are feared, if they are mishandles.
may lead to serious results depending upon the
Caution
are feared, if they are mishandles.
Do not touch!
Take care of a high
Always connect a protective earthing terminal!
Take care of an electrical shock!
1
Take care of ignition!
temperature!
Page 3
General
Installation, Adjustment
Piping,
Wiring
Alarm
The works of transport, installation, piping, wiring, operation, control, maintenance
and inspection may only be executed by the experts, who are well skilled of
handling the Ring Blows. Otherwise, an ELECTRIC SHOCK, an INJURY or a FIRE
is feared.
Hot line works are forbidden. Work always with the power supply switched off.
Otherwise, an ELECTRIC SHOCK or a FIRE is feared.
Do not use the Ring Blow in an explosive atmosphere.
Otherwise, an INJURY or a FIRE is feared.
Ground the protective earthing terminal surely. Otherwise, an ELECTRIC SHOCK or a FIRE is feared.
In the Ring Blow is used as mounted on a ceiling or a wall, its fall is feared
depending on its mounting condition. Observe the catalog or instruction manual for
the details of usable range. An INJURY due to a FIRE is feared.
Connect it to the power supply cable according to the wiring diagram within
terminal box and the instruction manual. An ELECTRIC SHOCK or a FIRE due to
incorrect connection is feared.
Use it always at the voltage and frequency indicated in the nameplate on its main
body. A BURNOUT or a FIRE is feared.
Do not bend, stretch or pinch the power supply cable and the lead wire for the Ring
Blow by force. An ELECTRIC SHOCK or a FIRE is feared.
Operation
General
Restore the cover for terminal box to the original position after completion of every
work. Otherwise, an ELECTRIC SHOCK is feared.
Never access or touch any rotating body (cooling fan etc.) during running. A
CATCH-IN on an INJURY is feared.
Switch off the power supply always in case of power failure. An INJURY is feared
due to sudden work of the machine at restoration of power supply.
Switch off the power supply always when the Ring Blow is stopped because the
protection unit belonging to it worked. An INJURY is feared due to sudden work of
Ring Blow at recovery of the protection unit.
Caution
Do not use the Ring Blow out of the specifications described in the nameplate,
catalog and instruction manual. An ELECTRIC SHOCK, an INJURY or a DAMAGE
is feared.
Do not use the damaged Ring Blow. An ELECTRIC SHOCK, an INJURY or a FIRE
is feared.
Do not insert any foreign material or finger into the opening (opening in fan cover,
admission and discharge ports) of Ring Blow. An ELECTRIC SHOCK an INJURY or DAMAGE is feared.
We take no responsibility for modification by the customer, as they are out of the
scope of our responsibility.
2
Page 4
Transportation
Caution
Take full care of fall and tumbling down during transportation. An INJURY is feared.
Lift up the Ring Blow equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Blow on a machine, do not lift up the entire machine using the mounted hanger bolt. Verify the mass of motor based in the nameplate, package box, outline drawing, catalog or the like before lifting it and do not lift any more mass than the rated load of lifting tool. The gravity center of the Ring Blow is located at motor side, therefore, the Ring Blow inclines to one side during lift-up. Exert tension gradually on the wire and do not lift up suddenly. This lift-up work may only be executed by the qualified workers. Do not stay under the Ring Blow during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of
these cases
Ambient temperature should be kept –20℃~+60 during transportation.
Open the package after verifying the top and bottom of product. An INJURY is
feared.
.
Opening the
Package
Installation, Adjustment
Piping,
Wiring
Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
Verify if the product is just the ordered one. An INJURY, DAMAGE or a FIRE due
to use of the incorrect product is feared.
Never place any inflammable material around the Ring Blow. A FIRE is feared.
Do not place any obstacle against ventilation around the Ring Blow. A BURN or a
FIRE caused by abnormal heating due to disturbed cooling is feared.
Fasten the foundation bolts surely.
Insufficient fastening may cause an INJURY and DAMAGE due to shift of the Ring
Blow.
Never get on or hang on the Ring Blow. An INJURY is feared.
Ring Blow shell be always mounted on suitable place in order to see its nameplate
easily and do not put any obstacle in front of it. Do not dismount the nameplate.
Construct the piping and wiring according to the technical standard for electrical
equipment and the internal wiring provisions. A BURNOUT or a FIRE is feared.
For wiring to the terminal base in terminal box, fasten the terminal screws with a
torque of 1.0 to 1.3 Nm. Otherwise, DAMAGE of the terminal box is feared.
For measuring the insulation resistance, do not touch the terminal. An ELECTRIC SHOCK is feared.
Operation
No protection unit belongs to the Ring Blow except for some models. The installing of overcurrent protection unit is obliged based upon the technical standard for
electrical equipment. For preventing a FIRE and DAMAGE due to a motor burnout,
we recommend to install the protection unit other then overcurrent protection units (including a ground fault interrupter) based upon consulting with us.
If any abnormality occurs, stop the operation immediately and switch off the power
supply. An ELECTRIC SHOCK an INJURY or a FIRE is feared.
The Ring Blow becomes considerably hot during its operation. Take care not to
touch it by your hand or body. A BURN is feared.
Do not insert your finger or any others material into the opening of Ring Blow. An
ELECTRIC SHOCK an INJURY or FIRE is feared.
Wear stopples during operation to shut the big noise.
3
Page 5
Caution
Do not touch the terminal for measuring the insulation resistance. An ELECTRIC SHOCK is feared.
Maintenance
, Inspection
The Ring Blow becomes considerably hot during its operation. Take care not to
touch by your finger and body. A BURN is feared.
Take care, if you use a solvent or the like for cleaning the Ring Blow. A
POISONING is feared. Further, the use of thinner or benzene may cause
discoloring or exfoliation of coating on the Ring Blow.
Disassembly, The repair, disassembling and modification shall be executed only by experts. An
Repair,
Modification
Disposal
INJURY due to the edge of Impeller or key groove, an ELECTRIC SHOCK or a FIRE is feared.
Handle the Ring Blow as a general industrial waste, when it is be disposed.
Package Opening and Product Verification ---------------------------
When the Ring Blow has been delivered, verify the following points.
Caution
1. Verify the top and the bottom of product and open the package.
Otherwise, an INJURY is feared.
2. Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
3. Verify if the delivered product is just the ordered one.
Check the output voltage, frequency, model etc. with the description on face plate. An INJURY, DAMAGE or a FIRE is feared, if an incorrect product is used.
4. Verify if any part is damaged and if any bolt or nut is loosened during the transport.
4
Page 6
Transport-------------------------------------------------------------------------
Take care of the following points for transporting the Ring Blow.
Caution
1. Take full care of fall and tumbling down during transportation. An INJURY is feared.
Lifting method of the Ring Blow
2. Lift up the Ring Blow equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Blow on a machine, do not lift up the entire machine using the mounted hanger bolt. Verify the mass of motor based in the nameplate, package box, outline drawing, catalog or the like before lifting it and do not lift any more mass than the rated load of lifting tool. The gravity center of the Ring Blow is located at motor side, therefore, the Ring Blow inclines to one side during lift-up. Exert tension gradually on the wire and do not lift up suddenly. This lift-up work may only be executed by the qualified workers. Do not stay under the Ring Blow during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of these
.
cases
3.
Ambient temperature should be kept –20℃~+60℃ during transportation.
Hanger bolt (in the case of the upper casing)
(VFC408~VFC 708) (VFC 808、VFC 908)
Gravity Center
Hanger bolt (in the case of the upper motor)
Gravity Center
Safekeeping---------------------------------------------------------------------
Take care of following points for safekeeping the Ring Blow or suspending its operation for a long period.
1. For safekeeping in the packed.
Keep the Ring Blow in an indoor dry place (Ambient temperature: -20℃~+50℃). Do not keep it on such a place, as is exposed to water or dust, or with vibration, or place it on a bare ground directly.
2. For keeping it in the installed condition.
(a) Cover the entire Ring Blow with a sheet for protecting it from invasion of moisture foreign
materials.
(b) Keep the Ring Blow with its hanger bolt mounted. If it is kept with the hanger bolt dismounted,
water may sometimes invade into through the screw hole.
(c) Run the Ring Blow for some minutes keeping it and every 3 months, for protecting the bearings
from rusting.
(d) If the operation of Ring Blow is suspended for a long period, measure the insulation resistance
of its winding every 6 months and verify that it is kept at higher than 1 M. If the resistance is not higher then 1 M at normal temperature, such measures are required as to dry the winding.
(e) Keep the Ring Blow in an indoor dry place (Ambient temperature: -20℃~+50℃).
5
Page 7
Gutter
Name of parts-------------------------------------------------------------------
Silencer
Fan cover
Cooling fan
Terminal box
Oil seal
Motor
Casing
End cover
Casing cover
Suction port Delivery
port
Impeller
Cross section of VFC508A
Installation and Piping --------------------------------------------------------
1 Take care of the following points for installing and adjusting the Ring Blow.
Alarm
1. Ground the protective earthing terminal surely.
An ELECTRIC SHOCK or a FIRE is feared.
2. In case of using the Ring Blow mounted on a ceiling or wall, its fall is feared depending upon the condition. Follow the catalog or instruction manual for details of usable range.
INJURY caused by its FALL is feared.
Caution
3. Never place any inflammable object around the Ring Blow.
A FIRE is feared.
4. Do not place any obstacle, which disturbs the ventilation, around the Ring Blow.
A BURN or a FIRE caused by abnormal heating are feared, due to the disturbed
ventilation.
5. Fasten the foundation bolts surely before starting the operation. An INJURY or DAMAGE due to shift of the Ring Blow is feared, if the fastening is insufficient.
6. Never step on or hang from the Ring Blow
An INJURY is feared.
7. Make the nameplate for the Ring Blow always easily legible and do not place any obstacle In front or it. Do not dismount the face plate.
6
Page 8
2 Take care of the following ranges for the installation site and the gas to be transported.
φ
φ
φ
φ
Caution
1. Outdoor/indoor
2. Ambient temp./
transport gas
3. Relative humidity /
altitude
4. Atmosphere /
gas to be transported
Install at an indoor site, which is exposed to no wind and rain
Otherwise, an ELECTRIC SHOCK or a FAULT is feared.
Use it in the range from -10 to 40 and a
FAULT
is feared. (No freezing is allowed.)
. Otherwise, shortening of life
Use relative humidity in 80% or less and 1000m above sea level
or less. Shortening of life or FAULT
is feared.
If can neither be used in a place, where any such corrosive liquid or gas as an acid or an alkali or any inflammable or explosive
gas exists, nor trans port such material. A FIRE, a FAULT or a INJURY is feared.
5.
Dusts
Evade a place, where a lot of dusts, wastes or thread chips exist. If inevitable, clean the dusts and wastes adhered in the blower regularly.
A FIRE or a FAULT is feared
6.
Ventilation
7.
Ambient air
8. Vibration
Select a well ventilated place. It shell not be used in a closed room or in a case. A
FIRE, a BURN or a FAULT is feared.
Evade a narrow place, for the convenience of maintenance and inspection.
Select a place, where no external vibration is added to the blower. If inevitable, take anti-vibration measures for protecting
from addition of vibration the blower. A FAULT, DAMAGE or an INJURY is feared. The value in Figure 1 is recommended as the
tolerable vibration value.
Size and tightening torque (recommendation value) of the anchor bolt
Anchor hole
mm
10 M8 11.7
12 M10 23.4
15 M12 41.3
19 M16 105
Bolt size
mm
※ Bolt materials are recommended
values in case of SS, SWRM
Tightening torque
N・m
9. Install the Ring Blow so as to be used in horizontal shaft condition. For installing it in vertical or slant shaft condition, install it so that its blower side lies under its motor side (Figure 2).
<Good!> <No good!>
(Figure 1)
(Figure 2)
7
Page 9
10. Use such pipes as PVC-pipes, gas pipes, flexible hoses etc., which can hold the Ring Blow
f
g
yp
r
pressure and hoses other then metallic one for discharge side, use those once, which have a sufficient high-temperature resistance.
Lay piping so surely as to have no leakage (Figure 3).
Kind of piping for suction port and delivery port.
Type exclusively used for house T
e from VFC088A toVFC308A
Fasten surely using a hose band
Type for house and screwed pipes (Type from VFC408A to VFC608A)
In case of flexible house In case of screwed pipes
Fasten surely using a hose band
Commercial pipe
Type for companion flanges
Type from VFC708A to VFC908A Type from VFC708A to VFC908A
Flexible house
Type exclusively used for screw pipes
Companion
flange
Flange
Flexible house
In case of piping to companion flanges, companion flanges must be remove form the Ring Blow before piping, it should be assembled afte piping. Take care of the breakage by tighten pipes too much.
Plastic or steel pipe
Plastic or steel pipe
Figure 3
Piping for Ring Blow
Ideally, use pipes having the same diameter as standard pipes.
Use large diameter pipes for long piping having many bends
Pipe joint
Pipe support
Caution Arrange pipe-supports properly, so that no sel
weight and external load concentrate on pipe connections.
11. Do not allow any foreign material to intrude into the blower.
Economical for high pressure and small Air flow, as small pipes may be used.
Construct piping surely with no leakage. Pressure and Air flow will be reduced by leaka
e.
Figure 3
8
Page 10
12. The rotation direction shall be the arrow direction on the casing. The rotation direction can be seen at the shaft end at counter-blower side and it is also correct, if the wind direction coincides with the IN and OUT indicated at the pipe connection port. Reverse rotation is allowed, although the performance is reduced.
13. Connect the power cables by using gland or electrical conduit at wiring hole of the terminal box to protect dust, foreign objects, water and etc. into the terminal box inside.
14. Take care of edge of wiring holes at the terminal box. An INJURY is feared.
Operation ------------------------------------------------------------------------
Verify the following points for operating the Ring Blow.
Alarm
1. Never access or touch the rotating body (cooling fan etc.) during running.
CATCH-IN or INJURY is feared.
2. Turn the power supply switch off in case of power failure.
INJURY is feared, when the machine runs suddenly at the power restoration.
3. Be sure to turn the power supply switch off, in the Ring Blow has been stopped
because the attached protection unit has been activated. An INJURY is feared, as the
machine may run suddenly at the power restoration.
4. If any abnormality occurs, stop the operation immediately and turn the power supply
switch off. An ELECTRIC SHOCK, an INJURY or a FIRE is feared.
5. During operation the Ring Blow, it becomes considerably hot. Take care not to touch
by your hand or body. A BURN is feared.
6. During its operation, do not insert your finger or any other object into the opening (fan cover, admission and discharge ports etc.) of the Ring Blow.
An ELECTRIC SHOCK, an INJURY or a FIRE is feared.
7. If the Ring Blow is operated with closed condition, the motor and blower temperature rises drastically and its distortion or damage after long time operation is feared.
8. If the Ring Blow is operated at a wind flow rate not more then continuous operation range, the motor and blower temperature rises drastically and its distortion or damage is feared, if the operation is continued for along time.
9. The temperature of the air passing through the Ring Blow rises. Especially it reaches a high temperature at a nearly closed condition. Take care not to touch it by your
hand or body. A BURN is feared. Figure 6 shows the temperature rise.
Alarm
10. During its operation, the Ring Blow and discharged air will reach a considerably high
temperature. Do not use it in a narrow closed room. A BURN, a FIRE or DAMAGE is
feared. (Inquire of us, if you use it in closed operation.)
9
Page 11
11. The Ring Blow will be continuously at within the operation range shown on the wind flow rate to
(Fig
static pressure curve (shown in the catalog). This operation range is so wide that the machine can be operated at nearly closed pressure but, if you operate it at high pressure, especially take care not to exceed the operation range. If you must operate it at closed condition, arrange a bypass hole on the way, so that a more wind than required range flows through the blower even if the suction port is closes (Figure 4).
Item
Model
Delivery Suction
sec
Q ② sec ①Q ②
VFC088A,088P Cont. 0 Cont. 0
VFC108A,108P 600
0.05 /
0.1
600
0.05 /
0.1
VFC208A,208P 240 0.1 / 0.1 240 0.1 / 0.1
VFC308A,308P 120 0.3 / 0.4 120 0.3 / 0.4
VFC408A,408P 120 0 / 0.1 120 0 / 0.1
VFC508A,508P 60 0.2 / 1.3 60 0.2 / 1.2
VFC608A 60 0.8 / 1.6 60 0.8 / 1.6
VFC708A 30 1.8 / 2.5 30 1.5 / 2.0
VFC808A 30 2.5 / 4.0 30 2.0 / 3.0
VFC908A 30 4.0 / 5.5 30 3.0 / 4.0
Shut-off allowable time(sec)starting at a normal temperature.
Minimum required air flow at 50/60Hz
Q=㎥/min
For using with the suction side closed
Bypass hole
Valve
For using with the discharge side closed
Bypass hole
Valve
ure 4
12. For using air intermittently, the switching by means of a valve is recommended rather than the switching on and off of the motor (Figure 5). The standard for start and stop frequency of Ring Blow shall be not higher than the values in table below.
Valve
Release
Valve
Suction
ProductLoad
Blow
(Suction)
(Blow)
Figure 5
10
Switch suction and blow using the valve.
Page 12
Tolerable start/stop frequency for Ring Blow[Sw/Hr]
Model Value for frequency of 50/60Hz VFC088 – VFC308 30/20 VFC408 – VFC608 20/15 VFC708 – VFC908 15/10
*1 switchone cycle of ON and OFF
13. The characteristics differ a little when the machine is used at suction side and when used at discharge side, as shown in the characteristics curve. As the air specific weight becomes larger, when the discharge side is throttled, the static pressure becomes also larger.
14. Remove any solid object, dust, thread chip, water drop or the like before entering into the Ring Blow. Even if make no dust be sucked directly, take measures not to suck any dust staying around by mistake. Use of the dust staying around by mistake. Use of the dust collection sack in a vacuum cleaner or the like is recommended. Also, it is recommended to use a filter having considerably large space. Remove sometimes the dust collected in the filter. It may also be possible to make the dust blow off by reversing the Ring Blow, if it is possible.
15. If dusts adhered inside and outside of the blower (especially in the cooling air path for cooling fan cover), remove them. If adhered dusts increase, it causes such troubles as a temperature rise, a sink of wind flow rate and an increase vibration.
16. As the motor load (current) changes depending upon the air flow used by the Ring Blow, refer to the characteristics curve for setting the wiring capacity and protection relay.
17. The bearing, oil seal and silencer are consumables and need to be changed when their lives are arrived. Depending on the environment, in which the machine was used, the Impeller, casing, casing cover, and wire net are also included in consumables.
Intervals for inspection and exchange of consumables
Part name Inspection/exchange interval
Bearing 2 years
Oil seal At the same time as bearings
Silencer 2 years
*Standard for use in a standard environment. They may be shorter depending on the environment.
Table of bearing and oil seal
Model Grease
Load side No-load side Model Material
Bearing Oil seal
Urea VFC088A 6201ZZ 6201ZZ - -
Urea VFC108A 6202ZZ 6202ZZ 20-30-5 Nitrile rubber
Urea VFC208A 6202ZZ 6202ZZ 20-30-7 Nitrile rubber
Common to VFC-A, VFC-P,VFC-PN, VFC-AN, VFC-A-4Z
11
Urea VFC308A 6202ZZ 6202ZZ 20-30-7 Nitrile rubber
Urea VFC408A 6203ZZ 6203ZZ 22-35-7 Nitrile rubber
Urea VFC508A 6205ZZC3 6205ZZ 35-47-7 Nitrile rubber
Urea VFC608A 6205ZZC3 6205ZZ 35-47-7 Nitrile rubber
Urea VFC708A 6306ZZC3 6206ZZ 38-58-8 Nitrile rubber
Urea VFC808A 6308ZZC3 6207ZZ 50-64-10 Silicon rubber
Urea VFC908A 6309ZZC3 6306ZZ 55-72-9 Silicon rubber
Page 13
(Figure 6) Discharged air-temperature rise curve
Common to VFC-PF,VFC-PN, VFC-AN, VFC-A-4Z
18. Wire the power cables with motor terminals surely according to wiring figure in the terminal box or
Figure 7.
(※Wiring type of VFC808 and VFC908 is direct start type at shipping, therefore, change wiring type
Model VFC808, VFC908
Wires 2 wires 3 wires 6 wires
Connecting
method
VFC088PVF508P VFC088VFC708
Motor terminal
U V
R S
Power supply
Motor terminal
U VW
R S T
Power supply
Direct start type
(At shipping)
Motor terminal
V2
U1 V1 W1
R S T
W2
U2
Star-delta start type
Motor terminal
V2
U1
W2 W1U2
U1 V2 V1
W2 W1U2
Power supply
V1
Power supply
from direct start type to star-delta start type in case of using star-delta start type.)
(Figure 7) Wiring diagram
19. Confirm below items at test running, if inverter is applied for the Ring Blow operarion.
Resonance is feared by install condition of the Ring Blow. Avoid the frequency of the resonance
Vibration and noise become bigger by using inverter. Stop the operation immediately, if abnormal
temperature rise or vibration occurs.
Do not use over 60Hz to protect motor burning.
(Maximum frequency of the 50Hz exclusive model is 50Hz.)
12
Page 14
Faults and Countermeasures-----------------------------------------------
In case of occurrence of any fault in the Ring Blow, handle it properly referring to Table 1 “Fault States of Ring Blow and Countermeasures” (page 12) and taking care of the following points.
Caution
1. Always only the expert shall investigate, repair, disassemble and modify the fault. An
INJURY due to the Impeller edge or key groove, an ELCTRIC SHOCK or a FIRE is
feared.
2. If the Ring Blow must be abandoned as the result of investigation in a rare possibility, dispose it as a general industrial waste.
3. If the investigation result shows that the machine cannot be easily repaired, if you will request any spare part or you have any trouble, contact our agent, dealer or business office at any time. In case of contacting us, please verify following items in advance:
(a) Model indicated in the nameplate, (b) SER. No., (c) Details of the fault, (d) Name of faulty part, name of spare parts, (e) Required quantity and (f) Kind of gas to be transported (e.g.Air)
13
Page 15
Table - 1 Fault States of Ring Blow and Countermeasures
States of Fault Causes Countermeasures
Switch-contact fault Repair switch-contact.
Fuse blown Replace it.
Does not
rotate
Rotates
Whining sound
No sound
Fuse blown
Motor overheated
Whining sound
One phase of power supply connection wires disconnected.
One phase of stator coils disconnected.
Stator and rotor come into contact due to bearing fault.
Foreign material involved in blades. Remove it.
Power failure Consult with utility company.
2 phases of power supply connection wires disconnected.
2 phases of stator coils disconnected. Request factory to repair them.
Switch fault Replace or replace it.
Insufficient fuse capacity Replace it with lager capacity.
Short-circuit in circuit Repair or replace it.
Power supply voltage fell Consult with utility company.
Single phase operation Request factory to repair it.
Impeller rubbing Adjust wheel.
1 phase short circuit in stator coils. Request factory to repair it.
Uneven space between stator and rotor.
Blade wheel rubbing Adjust it.
Replace it.
Request factory to repair it.
Replace bearing.
Replace them.
Request factory to repair it.
Abnormal noise
Motor rotates but fan works improperly.
Blade damaged due to foreign material.
Bearing fault Replace it.
Leakage in piping. Fasten tightly.
Piping blocked Ventilate sufficiently.
Reverse rotation direction Correct connection (2 out of 3
Closure equipment fault Replace it.
Request factory to repair it.
wires).
14
Page 16
Parts List and Disassembled Drawings ----------------------------------
The Parts List of Ring Blow is shown below. The Parts No. in Parts List corresponds to those in Disassembled Drawings. Caution: Some parts are not used for some machine models.
Part No. Name of Part Part No. Name of Part Part No. Name of Part
1-1 2-20 4-14
Casing Cover Washer Silencer Box Nut-Frame
Bolt-Casing Cover Rotor and Shaft Assembly Bolt-Bearing Retainer-Front
1-2 3-1 4-19
1-3 3-4 4-19
Impeller Bearing-Rear Bolt-Bearing Retainer-Front
2-1 3-5 4-20
Casing Bearing-Front Bearing Retainer-Front
2-2 3-6 4-24
Bolt-Casing Bearing Shim Front Frame Cover
2-3 3-7 5-1
Spring Washer Plate Retaining Terminal Box
2-4 3-8 5-2
End Cover Bolt-Impeller Gasket-T.Box
2-5 3-9 5-3
Bolt End Cover Tab Washer Cover-T.Box
2-6 3-11 5-4
Spring Washer Key-Impeller Bolt-T.Box
2-7 3-12 5-5
Silencer Assembly Motor Fan Washer-T.Box Ground
2-8 3-13 5-7
Flange Bolt-Motor Fan Bolt-T.Box Cover
2-9 3-14 5-8
Bolt-Flange Key-Motor Fan Grommet-T.Box
2-10 3-15 5-9
2-11 4-1 6-1
2-12 4-4 6-2
2-14 4-5 6-4
2-15 4-7 6-5
2-16 4-8 6-6
2-17 4-9 6-7
2-18 4-13 6-8
Gasket-Flange Collar Bolt-Ground
Threaded Flange Frame Stator Capacitor and Cap. Assy
Bolt- Threaded Flange Rear Housing Bushing-Capacitor
Shaft Seal Spring Washer Cap-Capacitor Assembly
Silencer Retaining Net Bolt-Rear Housing Washer-Capacitor
Silencer Box Fan Cover Bolt-Cap. Lead
Bolt-Silencer Box Bolt-Fan Cover Bolt-Cap.
Lifting Bolt Bolt-Frame Spring Washer
3-73-83-94-84-9VFC108A,AF(P) : Not applicable
5-15-25-3VFC088A,AF(P,PF), Thru VFC308A,AF(P,PF) And VFC408P : Not applicable
3-15VFC088A,AF(P,PF), 508A,AF(P,PF) Thru VFC708A : Not applicable
15
Page 17
VFC088A~VFC608A, VFC088P~VFC508P
VFC708A~VFC908A
16
Page 18
VFC088AF~VFC608AF, VFC088PF~VFC508PF
17
Page 19
Guarantee Period and Scope of Guarantee ----------------------------
Product guarantee and scope of guarantee
The guarantee period of for product shall be 1 year after shipment to the specified destination. If any
fault has occurred during the guarantee period in a proper use condition within he product specification range, the faulty part will be exchanged or repaired free of charge.
However, if the fault corresponds to any of the following cases, it will be excluded from the scope of
guarantee:
1due to improper handling or use by the User
2due to causes of fault other then of delivered product
3due to improper repair of modification
4due to natural calamity or disaster, which does not belong to the responsibility of supplier. The
said guarantee means the guarantee for supplied product itself and we take no responsibility
for the damage induced from the fault of the product. The guarantee is effective only in Japan.
Charged repair
The investigation and repair after the expiration of guarantee period will be charged. Even during the
guarantee period, we accept the repair of fault and the cause investigation due to reasons out of the scope of guarantee for payment.
18
Page 20
Head Office
230, Moriwake, Miyuki-cho, Fukuyama-city, Hiroshima, 720-0003, Japan
Tel.+81-84-955-1111 Fax.+81-84-955-5777
www.teral.net
2016 06
E‑IMN‑00367‑000‑T
Loading...