Teracue DCH-510P User Manual

DCH-510P™ User Guide V1.1
1
DDCCHH--551100PP™™
User Guide V1.1
Teracue AG
Schlossstr. 18 85235 Odelzhausen Germany
Tel: +49 (0)8134-555-10 Fax: +49 (0)8134-555-199
info@teracue.com www.teracue.com
Document Version 1.1/121203
DCH-510P™ User Guide V1.1
2
DCH-510P™ User Guide V1.1
3
C
OPYRIGHT
This document may not be reproduced in any form, in whole or in part, without the prior permission of Teracue. Copyright © 2012 by Teracue, all rights reserved.
D
ISCLAIMER
This publication supersedes all previous publications.
Information and specification in this documentation is subject to change without notice. Please make sure you have the latest document version. Documents are located at: www.teracue.com/support
If you find some points in this document unclear then please let us know, so we can improve this documentation. Thank you! Mail to: documentation@teracue.com
All information within this document is confidential to Teracue costumers and should not be copied or distributed to non Teracue customers.
T
RADEMARKS
All Teracue products and all of its components are registered trademarks licensed to Teracue.
All other logos and trademarks both marked and not, may be trademarks or registered trademarks and therefore property of their respective owners.
DCH-510P™ User Guide V1.1
4
I. Information about the manual
This manual is designed to help administrators and users to install the DCH-510P™ on their computer.
If you received this publication as a PDF, then it's a good idea to print it out for future reference.
It is best to use this user guide directly in front of your computer, by doing so you try out everything at once.
.!. Important features are marked by this sign.
DCH-510P™ User Guide V1.1
5
II. Content
1. BEFORE USING THE DEVICE ....................................................................................................... 6
1.1 F
OR YOUR SAFETY
.................................................................................................................... 6
1.2 WARNINGS ............................................................................................................................. 6
2. MODELS THAT ARE COVERED BY THIS USER MANUAL ......................................................... 7
3. INSTALLATION ............................................................................................................................... 7
3.1 I
NSPECTION
............................................................................................................................... 7
3.2 O
PERATING VOLTAGE
................................................................................................................ 7
3.3 T
HE FUSES
................................................................................................................................ 8
3.4 C
ONNECTING THE DEVICE
.......................................................................................................... 8
3.5 P
OWER ON THE DEVICE
.............................................................................................................. 9
4. NAVIGATING THE FRONT PANEL ................................................................................................ 9
5. MENU STRUCTURE AND OPERATING THE DEVICE ................................................................. 9
5.1 I
NPUT MENU
............................................................................................................................ 10
5.1.1 Status Menu ....................................................................................................................... 10
5.1.2 DVB-S2 Menu .................................................................................................................... 10
5.1.3 RSSI .................................................................................................................................. 10
5.1.4 Ethernet Menu ................................................................................................................... 11
5.2 O
UTPUT MENU
........................................................................................................................ 11
5.2.1 BISS Menu ......................................................................................................................... 12
5.2.2 CI Menu ............................................................................................................................. 12
5.2.3 Decoder ............................................................................................................................. 13
5.2.4 ASI ..................................................................................................................................... 15
5.2.5 ASI2 ................................................................................................................................... 15
5.2.6 SDI ..................................................................................................................................... 15
5.2.7 MUX ................................................................................................................................... 16
5.2.8 Ethernet ............................................................................................................................. 17
5.3 S
YSTEM MENU
......................................................................................................................... 19
5.3.1 Local Setup ........................................................................................................................ 19
5.3.2 Trap IP Address ................................................................................................................. 19
5.3.3 Unit Name .......................................................................................................................... 19
5.3.4 Properties .......................................................................................................................... 20
5.3.5 Factory Setting ................................................................................................................... 20
5.3.6 Optional Function............................................................................................................... 20
5.3.7 Machine Type .................................................................................................................... 20
6. SPECIFICATION ............................................................................................................................ 21
7. IPTV CONFIGURATION QUICK GUIDE ....................................................................................... 23
7.1 H
OW TO RECEIVE A MULTICAST OR UNICAST STREAM
............................................................... 23
7.2 H
OW TO SET THE UNICAST/MULTICAST OUTPUT
......................................................................... 24
8. CONTROL WITH WEB SERVER .................................................................................................. 25
9. STATEMENT OF CONFORMITY .................................................................................................. 30
DCH-510P™ User Guide V1.1
6
1. Before Using the Device
Thank you for purchasing the DCH-510P™ series. This User Manual is written for operators/users of the DCH-510P™ Multi-Format Professional HDTV Processor to assist in installation and operation. Please read this user manual carefully before installation and use of the device.
1.1 For Your Safety
This equipment is provided with a protective earthing ground incorporated in the power card. The main plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor, inside or outside the device, is likely to make the device dangerous.
Do not remove the covers of this equipment. Hazardous voltages are present within this equipment and may be exposed if the covers are removed. Only Teracue trained and approved service engineers are permitted to service this equipment.
No operator serviceable parts inside. Refer servicing to Teracue trained and approved service engineers.
For the correct and safe use of the device, it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual.
Whenever it is likely that safety protection is impaired, the device must be made in-operative and secured against unintended operation. The appropriate servicing authority must be informed. For example, safety is likely to be impaired if the device fails to perform the intended measurements or shows visible damage.
1.2 WARNINGS
The mounting environment should be relatively dust free, free of excessive vibration and the
ambient temperature between 0 °C to 40 °C. Relative humidity of 20% to 80% (non­condensed) is recommended.
Avoid direct contact with water. Never place the equipment in direct sunlight. The outside of the equipment may be cleaned using a lightly dampened cloth. Do not use any
cleaning liquids containing alcohol, methylated spirit or ammonia etc.
For continued protection against fire hazard, replace line fused only with same type. Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air
flow should not be obstructed. Therefore, the device has to be placed on a flat surface, leaving some space at the sides of the device.
When in operation, the internal temperature should not exceed the limit of 70 °C.
DCH-510P™ User Guide V1.1
7
2. Models that are Covered by this User Manual
Model DCH-510P™-x DCH-510P™-x-x
Tuner -T2 -C -T -S2 -T2-IP -C-IP -T-IP -S2-IP
ASI Input x2 x2 x2 x2 x2 x2 x2 x2
CI x2 x2 x2 x2 x2 x2 x2 x2
Built-in Re-MUX
ASI-Output (Redundancy)
GbE IP In/Out
HDMI x1 x1 x1 x1 x1 x1 x1 x1
SDI x1 x1 x1 x1 x1 x1 x1 x1
YPbPr x1 x1 x1 x1 x1 x1 x1 x1
Audio L/R x2 x2 x2 x2 x2 x2 x2 x2
AES-EBU x2 x2 x2 x2 x2 x2 x2 x2
CVBS x2 x2 x2 x2 x2 x2 x2 x2
= Standard Configuration
3. Installation
3.1 Inspection
Open the packaging box, check if all appendixes are in the box according to the appendix list, and if the device has any visible damage, please contact the agent.
3.2 Operating Voltage
Do not connect AC power until you have verified that the line voltage is correct and the proper fuses are installed. The device’s power supply is fitted with a wide-ranging power supply. It is suitable for supply voltages of 100-240 Vac -10% +6% at 50/60 Hz nominal. Be sure the supply voltage is within the specified range.
POWER REQUIREMENT
Input voltage 90-250 Vrms auto select Frequency 47 to 63 Hz Power 50 VA max. / 30 VA typical. Current 110 V/0.27A or 240 V/0.125A typical
DCH-510P™ User Guide V1.1
8
3.3 The Fuses
The recognized recommended fuses are size 5 by 20 mm, rate T 2.0A, 250 V (UL and IEC approved).
The line fuse is housed in a small container besides the power connector on the rear panel. To check the fuse, insert the tip of a screwdriver in the slot at the middle of the container and pry gently to extend the fuse where there is a little tap and pull out the fuse gently. The fuse is attached to the line module and cannot be removed.
3.4 Connecting the Device
Always use the specified cables supplied for signal integrity and compliance with EMC requirements.
The rear panel is directly related to the input and output options fitted. Below figure shows a typical rear panel.
TS/IP IP input/output port RS-232 serial port for printing information MANAGEMENT LAN port for software update ASI OUT2 Group2 ASI output port (one for back-up) ASI OUT1 Group1 ASI output port (one for back-up) ASI1 IN ASI1 input port ASI2 IN ASI2 input port SDI2 SDI2 output port SDI1 SDI1 output port HDMI HDMI output port CVBS CVBS BNC output port YPbPr YPbPr output port L-Audio-R1 Group1 RCA audio output port CVBS CVBS RCA output port L-Audio-R2 Group2 RCA audio output port Audio1 AES/EBU and Balance Audio output port1 (need to use the RS232-to-
XRL converting cable in accessories)
AUDIO2 AES/EBU and Balance Audio output port2 (need to use the RS232-to-
XRL converting cable in accessories) TUNER OUT Tuner signal loop through output port TUNER IN Tuner signal input GND Grounding terminal Power Socket AC 90~250V 50-60Hz input Switch Power switch
Management ASI Out2 ASI2 In SDI2 HDMI VBS L-Audio-R2 Audio2 GND Power Socket
TS/IP RS-232 ASI Out1 ASI1 IN SDI1 CVBS YPbPr L-Audio-R1 Audio1 Tuner out Tuner in Switch
DCH-510P™ User Guide V1.1
9
3.5 Power on the Device
Be sure the device is mounted into the rack properly and firmly, and the signal cables are connected well, then power can be applied to the device. The main socket and fuse are located at the rear panel of the device.
When the device is powered on, verify that the display shows the following message:
Digital TV Processor (factory default unit-name) IP: 10.10.60.148 (factory default IP Address for LAN access)
If no message is shown in the display or there is not light in the display, the device is defective and has to be returned for servicing.
4. Navigating the Front Panel
POWER Power indicator, green light means power is OK TUNER LOCK Tuner lock indicator, green light means signal is locked; if there is no light,
which means no signal input or wrong parameters setting. ALARM Alarm indicator LCD 2 × 20 character LCD Operation buttons
[ ] [ ] [ ] [ ]
[ENTER]
[EXIT]
buttons [ ] [ ] are used to up/down pages of menu or increase/decrease value when edit numbers [ ] [ ] are used to move cursor [ENTER] is used to enter sub menu or confirm operation [EXIT] is used to return previous menu or cancel operation
Common Interface PCMCIA Module slot
5. Menu Structure and Operating the Device
The menu structure of the device is showed in below figure. After initialization is completed, press [ENTER] button to enter main menu:
(1) Input Setup Set input parameters (2) Output Setup
Set output parameters
(3) System Set system parameters
Main Menu
Inputs
Outputs System
POWER TUNER LOCK ALARM LCD Operation Buttons Common Interface
DCH-510P™ User Guide V1.1
10
5.1 Input Menu
There are four options: Status, DVB-S2, RSSI and Ethernet (optional):
5.1.1 Status Menu
It contains four options, ASI1, ASI2, TUNER and IP IN, to show the status of signal input:
ASI1: When signal from ASI1 input port is locked, it will display package format and code rate;
if signal is not locked, it will show Unlock.
ASI2: When signal from ASI2 input port is locked, it will display package format and code rate;
if signal is not locked, it will show Unlock.
TUNER: When signal from tuner input port is locked, it will display package format and code
rate; if signal is not locked, it will show Unlock.
IP IN: When signal from IP input port is locked, it will display package format and code rate; if
signal is not locked, it will show Unlock (Note: this option only appears when the External Function is set as “IP IN”. Please refer to chapter 5.3.6 for setting method).
5.1.2 DVB-S2 Menu
There are 6 options to set DVB-S2 parameters. After signal is locked, the TUNER LOCK indicator on front panel will turn green.
LNB Frequency: Input LNB frequency  Satellite Frequency: Input downstream frequency of satellite  Symbol Rate: Input symbol rate of satellite  LNB Voltage: select the correct LNB voltage output of the F-connector: Off, 13 V, 18 V. <A>  LNB 22KHz: activate the LNB 22 kHz control signal to the LNB: On or Off. <B>  DISEQC: Can select OFF/Port A/Port B/Port C/Port D
Note: Please contact the local satellite operator for the satellite frequency and symbol rate.
<A> Normally, 13V switches the LNB to receive Vertical/Left hand
polarization while 18V receive Horizontal/Right hand.
<B> Normally, 22KHz control signal switches the LNB to receive high
band if any.
5.1.3 RSSI
There are two options to show the quality of receiving DVB-S2 signal.
Inputs
Status
DVB-S2
Ethernet
RSSI
DCH-510P™ User Guide V1.1
11
5.1.4 Ethernet Menu
(The Ethernet menu is showed only if the IP streaming in/out board is installed and the TS/IP streaming board is set to “IP IN”. Refer to chapter 5.3.6.)
The Ethernet connector is for receiving transport stream over IP. The Ethernet connector has user­configurable IP address, network mask and default gateway. These must be set to appropriate values for the network over which the transport stream over IP is received.
Stream IP Addr: Enter the IP address for streaming IP input of the unit.
Stream Netmask: Enter the network sub mask for the subnet to which the unit is connected
for IP streaming traffic.
Stream Gateway: Set the gateway for the network to which the unit is connected for IP
streaming traffic.
Stream Mac Address: factory-set MAC addresses are guaranteed to be unique. Therefore
you can not configure the address.
Multicast IP Addr: Enter the IP address of the multicast stream for the transport stream over
IP.
Multicast UDP Port: Enter the UDP port number of the TS over IP stream.
Protocol: select the protocol for multicast: UDP or RTP.
Output Smoothing: set the quality of TS which comes from the TS/IP input.
Auto:
The bit rate is variable.
Disable:
The unit let the TS pass by.
Fixed Rate:
The bit rate is fixed.
TS Bit Rate: set the bit rate of the TS from the TS/IP input. The setting is only valid when the
output smoothing is configured as Fixed Rate.
5.2 Output Menu
Under Output Menu, you can monitor and configure the parameters of the CI, AV decoder, ASI out, ASI2/SDI out, MUX (A), BISS, SDI out and TS over IP output (B).
Note: (A)The MUX menu is showed only if the built-in MUX portion is enabled. Refer to chapter
5.3.6. (B) The Ethernet menu is showed only if the IP streaming in/out board is installed and the TS/IP streaming board is set to “IP Out”. Refer to chapter 5.3.6.
Outputs
BISS CI Decoder ASI1 ASI2 Ethernet Mux
SDI
DCH-510P™ User Guide V1.1
12
5.2.1 BISS Menu
It includes Biss Mode, Biss 1 Setup and Biss E Setup.
Biss Mode: Set Biss mode, can select OFF, Biss E or Biss 1 Biss 1 Setup: Set Biss 1, password is required Biss E Setup: Set Biss E, ID number and password are required
5.2.2 CI Menu
There are two PCMCIA slots for inserting CAM’s for decrypting program from the input signal.
Before setting CI, ensure the signal from ASI input is locked or the Tuner locks on the correct Transponder (this depends on in which signal the encrypted program is carried). The ‘Tuner Lock’ LED is 'on' in green.
There are 3 submenus: ‘CI Source’, ‘Setup’ and ‘CAM name’ which allow you to set or select the parameters of the CI.
CI Source: press the <ENTER>-key, then use < > or < >-key select Tuner or ASI1 input or ASI2 input or TS/IP input (only when the TS/IP is set “IP in”, refer to chapter 5.2.7 for details) to set the signal source of descrambling, press <ENTER>-key to save or press <EXIT>-key to scrap.
Setup: under this sub menu, you can see all program names from the source of CI that was set in ‘CI Source’ previously. All free programs are marked with ‘Free’ in the first row.
To select which program to be decrypted, press the < > or < >-key to roll up and down the program names and press <ENTER>-key to change the status of the corresponding program (only encrypted program could be selected). Three different statuses could be set:
Slot 1 (decrypted with upper CAM inserted) Slot 2 (decrypted with lower CAM inserted) Bypass (no decryption).
The status will be shown in the first row on the LCD display. Confirm this setup when leaving this sub menu, press <ENTER>-key to save or press <EXIT>-key to scrap.
The decrypted program could be delivered to other functional portions, like A/V decoder, ASI1, ASI2, SDI, MUX and TS/IP output (refer to chapter 5.2.3 ~ 5.2.8 for more).
CAM name: under this sub menu, you can see the names of CAM modules.
DCH-510P™ User Guide V1.1
13
5.2.3 Decoder
You can configure the parameters of Video and Audio of the program decoded by AV decoder.
Status: OK or Alarms indicates the status of the decoder. You can use the <ENTER>-key to check detailed information.
Source: Press the <ENTER>-key and use the < > or < >-key to roll up or down to select the signal source of ASI output, there are 5 types of signal source optional:
CI Decrypted:
The decrypted transport stream from CI functional portion will be delivered to the ASI output port on the back panel.
TUNER:
The transport stream from Tuner will be delivered to the ASI output port on the back panel.
ASI1 Input:
The transport stream comes from ASI1 input port will be delivered to the ASI1 output port on the back panel.
ASI2 Input:
The transport stream comes from ASI2 input port will be delivered to the ASI2 output port on the back panel.
MUX TS:
The transport stream comes from built-in MUX will be delivered to the ASI output port on the back panel. (The MUX TS is valid only when the built-in MUX function is enabled and turned on. Refer to chapter 5.2.7 and chapter 5.3.6 for how to set the built-in MUX.)
Press <ENTER>-key to save or press <EXIT>-key to scrap. A few seconds after the source being selected, the TS will be delivered to the ASI output port on the back panel.
Program: under this sub menu, you will see all program names detected by DCH-510P™. The programs could be coming from ASI input, Tuner, TS/IP input, the internal CI decryption portion, BISS
Decryption portion or MUX TS. Use the < > or < >-key to roll up or down between the program names, and use < >-and < >-key to switch among input sources, where a number in front of the
program name indicates the input source:
0-xxxxx:
Displays the program name, which comes from ASI input.
1-xxxxx:
Displays the program name, which comes from TUNER input.
2-xxxxx:
Displays the program name, which comes from TS/IP input
3-xxxxx:
Displays the program name, which comes from the CI.
4-xxxxx:
Displays the program name, which comes from ASI2 input.
5-xxxxx:
Displays the program name, which comes from BISS Decrypted input.
6-xxxxx:
Displays the program name, which comes from MUX TS.
A few seconds after the program being selected, the A/V signal will be delivered to the related connectors on the back panel.
DCH-510P™ User Guide V1.1
14
Video: You can configure the video parameters of programs in this submenu. Press the
<ENTER>-key to confirm or press the <EXIT>-key to cancel.
Video Standard:
You can select Auto/1920x1080i 60/1920x1080i 50/1280x720p 60/1280x720p 50/720x480p 60/720x576p 50/525x480i 60/625x576i 50 for the video output.
Screen:
Select the screen mode: 4:3 Full, 16:9 Full or 4:3 Letterbox.
DVB Subtitle Lang:
Select the language of DVB Subtitle.
EBU Subtitle Lang:
Select the language of EBU Subtitle.
Subtitle Priority:
Configure the priority of Subtitle; choose whether DVB or EBU should be first.
Fail M
ode:
Set the status of decoder video output if the inputted signal fails. You can select Black Screen or No Sync or Still Picture
Audio: You can configure the audio settings in the submenu.
Audio1 Level:
Use the < > < > < > < >-keys to modify the audio1 level within this range: 0~99.
Audio1 Mode:
Select Stereo, Left, Right or Mono for soundtracks.
Audio1 Language:
Select the language of the audio.
Audio2 Level:
Use the < > < > < > < >-keys to modify the audio2 level within this range: 0~99.
Audio2 Mo
de:
Select Stereo, Left, Right or Mono for soundtracks.
Audio2 Language:
Select the language of the audio.
Video Format: the following table shows the available format on different connectors.
Output port Resolution SDI port 1080ix60, 1080ix50, 720px50, 576ix50, 480ix60
HDMI port
1080ix60, 1080ix50, 1280x720px60, 1280x720px50, 720x480px50, 720x576px50, 576ix50, 480ix60
YPbPr port
1080ix60, 1080ix50, 1280x720px60, 1280x720px50, 720x480px50, 720x576px50, 576ix50, 480ix60
CVBS port 576ix50, 480ix60
DCH-510P™ User Guide V1.1
15
5.2.4 ASI
You can configure the settings of ASI1 in this menu.
ASI1 Source: Press the <ENTER>-key and use the < > or < >-key to roll up or down to select the signal source of ASI output, there are 5 optional types of signal source:
CI Decrypted:
The decrypted transport stream from CI functional portion will be delivered to the ASI output port on the back panel.
TUNER:
The transport stream from Tuner will be delivered to the ASI output port on the back panel.
ASI1
Input:
The transport stream comes from ASI1 input port and will be delivered to the ASI1 output port on the back panel.
ASI2
Input:
The transport stream comes from ASI2 input port will be delivered to the ASI2 output port on the back panel.
MUX TS:
The transport stream comes from built-in MUX and will be delivered to the ASI output port on the back panel. (The MUX TS is valid only when the built-in MUX function is enabled and turned on. Refer to chapter 5.2.7 and chapter 5.3.6 for how to set the built-in MUX.)
Press <ENTER>-key to save or press <EXIT>-key to scrap. A few seconds after the source being selected, the TS will be delivered to the ASI output port on the back panel.
5.2.5 ASI2
Here is the same configuration method like chapter 5.2.4.
5.2.6 SDI
You can configure the settings of SDI output in this menu.
Audio PID:
Press the < > < >-keys to choose the audio PID from 1~4.
Embed Audios:
There are 4 options: none, one&two, two, and one.
SDI Output Mode:
Configure output mode HD-SDI or SD-SDI
SDI H Offset:
The range is 0~999
DCH-510P™ User Guide V1.1
16
5.2.7 MUX
Note this MUX menu is shown only when the built-in MUX function is enabled and turned on. And the MUX is alternative (refer to chapter 5.3.6 for how to turn on and set the built-in MUX).
MUX Switch: the internal multiplexer could be switched On/Off. The default value is ‘off’. To activate the re-multiplexing function, you should turn on this built-in MUX function.
Bit Rate: should be set to a specified value that doesn’t exceed the maximum physical limit of the output medium. For example, to deliver the multiplexed TS to an 8MHz DVB 256QAM modulator, it should not exceed 55000Kb/s, otherwise overflow occurs.
TS ID: you can configure the TS ID to mark the multiplexed TS. Default value is 1.
Program List: press the <ENTER>-key to enter ‘MUX List’ sub-menu. It shows all programs detected by DCH-510P™. The programs come from ASI input, Tuner, TS/IP input or the internal CI decryption.
Use < > < >-keys to roll up the program names, and use < > < >-keys to switch among input sources, where a number in front of the program name indicates the input source:
0-xxxxx:
Displays the program name, which comes from ASI input.
1-xxxxx:
Displays the program name, which comes from TUNER input.
2-xxxxx:
Displays the program name, which comes from TS/IP input
3-xxxxx:
Displays the program name, which comes from the CI.
4-xxxxx:
Displays the program name, which comes from ASI2 input.
5-xx
xxx:
Displays the program name, which comes from BISS Decrypted input.
On ‘Program List’ sub-menu, on the first row, all encrypted programs are labeled with a ‘$’ sign. All programs that are being selected to be re-multiplexed are labeled as ‘Pass’, otherwise, the un­selected programs are labeled as ‘Forbid’. Use <ENTER>-key to selected or un-selected the program being shown.
When leaving the ‘Program List’ sub-menu, a new menu will be shown ‘Confirm changed?’ Press
<ENTER>-key to validate all programs selected to be multiplexed or to scrap by pressing <EXIT>­key.
After a few seconds, the multiplexed TS will be generated and delivered to the specified destination(s).
DCH-510P™ User Guide V1.1
17
5.2.8 Ethernet
(Note this menu is shown only when the TS/IP streaming is installed and the board is set to “IP Out”, refer to chapter 5.3.6 for how to set up.)
The TS/IP Ethernet connector could also be configured as the output of the transport stream over IP. The parameters listed below must be set to appropriate values for the network over which the transport stream over IP is broadcasted.
Stream IP Addr: enter the IP address for the IP hardware board (should be the same network
section of the IP Board Gateway, this depends on the characteristic of the gateway).
Stream Netmask: enter the network submask for the IP hardware board.
Stream Gateway: enter the Gateway address for the IP hardware board.
Stream Mac Address: Show the MAC address of this IP hardware board, read only.
Protocol: select the protocol of the output stream. The unit supports UDP or RTP.
TS Pkts per UDP: set the quantity of TS packages that will be carried IP package. The range
goes from 1 ~ 7.
Time To Live: set the TTL for the output IP package.
Type of Service: set the type of service for the output IP stream.
Source: set the wanted stream output via IP. The stream could be from one of the following
combinations:
ASI1
Input
ASI2
Input
CI Decrypted
MUX TS
(note the MUX TS is showed only when the built-in MUX function is enabled and turned on. Refer to chapter 5.2.7 and chapter 5.3.6 for how to set the built-in MUX)
After the operation, the selected transport stream will be delivered to the TS / IP function portion for further operation.
Mode: select the mode of IP stream. You can set it as DVB mode or IPTV mode.
DVB mode:
The transport stream which comes from the ‘source’ selected previously will be packed into IP Stream directly. Therefore the contents inputted via the source will not be touched and be delivered to the specified Multicast or Unicast IP address.
IPTV mode:
The transport stream which comes from the ‘source’ selected previously will be de-MUXed into several SPTS, and each one is packed into one IP stream. Therefore each IP stream carries only one program and be delivered to the specified Multicast or Unicast IP address. You can configure a maximum of 6 or 32 IPTV channels which depends on the model you operate on.
Multicast Setup: use <ENTER>-key to enter sub-menu. The sub-menu is different according
to different ‘mode’ selected in previously. See below:
DCH-510P™ User Guide V1.1
18
DVB mode
Multicast IP: Enter the IP address of the IP stream for the transport stream over IP output.
You can configure the IP stream output mode in Multicast or Unicast.
Multicast
could be established by setting Multicast IP address in the range of
239.255.255.255 to 224.0.0.0.
Unicast
could be established with the same settings of Multicast, the only
differences are the Multicast IP address, and should NOT be in the range of
224.0.0.0 to 239.255.255.255, which is for Multicast. Although the display is 'Multicast IP' on the first row, the stream itself is Unicast. The IP address of receiver device (maybe PC with XPlayer™) needed to be set to as the unicast address on DCH-510P™, please don't use DHCP to get a dynamic IP address for receiver device.
Multicast UDP Port: Enter the UDP port number of the TS over IP stream output.
IPTV mode
Max Channels (<=32): you can configure the number of IPTV channel. The valid range goes
from 0 to 32.
After the configuration, you can use < > < >-keys to roll up and down between the channels. Each channel should be configured independently.
Channel x: ‘x’ stands for the channel number. Press <ENTER>-key to go down to the sub-
menu. There are 4 sub-menus:
x-Multicast IP:
Enter the multicast IP address for the output stream (for the addresses inside 224.0.0.1 to 239.255.255.255 are belonging to multicast, for others else are belonging to unicast, the DCH-510P™ will identify it automatically)
x-Multicast Port:
Enter the port number of the output stream.
x-Switch:
Each channel could be switched On/Off independently. The default value is ‘off’.
x-Program:
it shows all programs carried by the transport stream from the source selected. Press <ENTER>-key and use < > < >-keys to
roll up and down between the program names, where a number in front of the program name indicates the input source:
0-xxxxx:
Displays the program name, which comes from ASI input.
1-xxxxx:
Displays the program name, which comes from TUNER input.
2-xxxxx:
Displays the program name, which comes from TS/IP input
3-xxxxx:
Displays the program name, which comes from the CI.
4-xxxxx:
Displays the program name, which comes from ASI2 input.
5-xxxxx:
Displays the program name, which comes from BISS Decrypted input.
6-xxxxx:
Displays the program name, which comes from MUX TS.
All encrypted programs are labeled with a ‘$’ sign on the first row. Press <ENTER>-key to the program just be selected to be delivered to the specified IPTV channel or to scrap by pressing <EXIT>-key.
DCH-510P™ User Guide V1.1
19
5.3 System Menu
There are seven sub-menus:
5.3.1 Local Setup
Each DCH-510P™ has an IP address, a network sub mask and a gateway. These must be set to an appropriate value for the network over which the unit can be accessed by the remote control system such as the HDMS.
IP Address: set the IP address of the unit.
Network Mask: set the network mask for the subnet to which the unit is connected.
Gateway: set the gateway for the network to which this unit is connected.
5.3.2 Trap IP Address
The DCH-510P™ provides a Monitor Center IP address. You can set this to be the same IP address of the Monitor Center, which is typically a PC in order to allow the device to send messages to the monitor center.
5.3.3 Unit Name
The DCH-510P™ allows you to edit the unit name which is displayed on the front panel LCD. Default name is ‘Digital TV Processor”. The unit name should not be longer than 20 characters in ASCII format.
System
Local Setup
Properties
Factory Setting
Optional
Function
Machine Type
HTTP Login
Unit Name
Trap IP
DCH-510P™ User Guide V1.1
20
5.3.4 Properties
Version: show software version of this device
MAC Address: Factory-set MAC address which is guaranteed to be unique. You cannot
configure this address.
Linux OS version: show Linux OS version
ARM SW version: show ARM software version
Decoder version: show Decoder version
FPGA version: show FPGA version
TS/IP IN (or OUT) NIOS: it’s changed when TS/IP board is set to “IP Out” or “IP IN”.
TS/IP IN (or OUT) FPGA: it’s changed when TS/IP board is set to “IP Out” or “IP IN”.
5.3.5 Factory Setting
All the user configurable parameters will be set to the factory default settings, including IP address and the unit name.
5.3.6 Optional Function
There are two submenus:
External Board Type: Press <ENTER>-key to active the menu, use < > < >-keys to
configure the TS/IP portion as ‘IP in’ or ‘IP out’ or ‘No Exist’, and the option is exclusive. Press <ENTER>-key to confirm or to scrap by pressing <EXIT>-key.
After the operation, you need to reboot the unit to valid the configuration.
IP in:
The TS/IP port is configured as input, you can feed transport stream over IP into the unit. The menu ‘Ethernet’ will be showed under the inputs menu.
IP Out:
The TS/IP port is configured as output, you can set the transport stream over IP output to the IP network. The menu ‘Ethernet’ will be shown under the output menu.
No Exist:
The TS/IP port is invalid. Therefore the menu ‘Ethernet’ will not be shown anywhere.
MUX Function: Press <ENTER>-key to active the menu, use < > < >-keys
to configure the built-in MUX as ‘Enable’ or ‘Disable’. Press <ENTER>-key to confirm or to scrap by pressing <EXIT>-key.
5.3.7 Machine Type
This setting is reserved for factory configuration only.
DCH-510P™ User Guide V1.1
21
6. Specification
DVB-S2 Demodulation
Input frequency range 950~2150MHz Input level 25~-65dBm Input impedance 75 Connector F Connector Symbol rate 2~45MBauds for QPSK; 2~45MBauds for 8PSK Rolling off factor 0.35 for QPSK; 0.35, 0.25, 0.2 for DVB-S2 Punctured rates DVB-S QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9,8/10
DVB-S2 8PSK 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 LNB Level 0, 13V, 18V adjustable 0/22K 0/22KHz selectable DiSEqC DiSEqC 1.0
DVB-C QAM Demodulation
Tuner Input symbol rate 1~7Mbps(PAL), 1~6Mbps(NTSC) Demodulation 16/32/64/128/256 QAM Bandwidth 6MHz or 7MHz or 8MHz Input frequency 48~860MHz Input level -15~15dBmV Input impedance 75, IEC female
DVB-T COFDM Demodulation
Demodulation QPSK, 16QAM, 64QAM Bandwidth 6MHz/7MHz/8MHz FFT mode 2K/8K Guard interval 1/4, 1/8, 1/16, 1/32, off FEC code rate 1/2, 2/3, 3/4, 5/6, 7/8 Input frequency 470-862MHz
UHF ; 174-230MHz
VHF Input level -20~-70dBmV Input impedance 75, IEC Female
TS over IP I/O
Ethernet Connector RJ45, 10/100M Max. bit rate 70Mbits/s Protocol UDP/RTP, Support Multicast or Unicast Multicast control protocol IGMPV2
Other I/O Interface / Common Interface
Type double-deck PCMCIA
Input Interface
Tuner IN 1×input, 1×loop through output ASI OUT 2× BNC Female, 75
Output Interface
ASI OUT 2×2 BNC Female,75 SDI OUT 2×BNC Female,75. Supports HD-SDI/SD-SDI,(one for back-
up)optional HDMI 1x HDMI 1.3 interface YPbPr 1 CVBS 1×RCA,1xBNC AES/EBU 2x9-pins D-sub connector, AES/EBU and XRL audio output ports Serial Port 1xRS-232 9-pin D-sub Ethernet Connector ×RJ45, 10/100M, for network management; 1×RJ45, 10/100M, for TS
over 1 IP (optional)
Output Video format
SDI 1080ix60, 1080ix50, 576ix50, 480ix60, 1280x720Px 50, 1280x720Px 60,
1080ix59.94 HDMI 1080ix60, 1080ix50, 1280x720px60, 1280x720px5, 720x480p60,
720x576p50, 576ix50, 480ix60, 1080ix59.94
DCH-510P™ User Guide V1.1
22
YPbPr 1080ix60, 1080ix50, 1280x720px60, 1280x720px50, 720x480p60,
720x576p50, 576ix50, 480ix60, 1080ix59.94 CVBS port 576ix50, 480ix60
Management
Ethernet Connector RJ45, 10/100M, for NMS and software upgrade Protocol SNMP, TCP/IP, HTTP Front panel control LCD display and keypad
General
Power supply AC 90V~260V 50Hz/60Hz 30W Weight 5Kg Dimensions 44x483x255mm Operating temperature 0~45 °C Humidity <95%
DCH-510P™ User Guide V1.1
23
7. IPTV Configuration Quick Guide
First of all, make sure that your unit is equipped with IP hardware board. If not, please contact your agent for information.
7.1 How to Receive a Multicast or Unicast Stream
Normally, the DCH-510P™ is set to IP Output by the factory. To set the DCH-510P™ to IP input mode, please follow the procedure below:
1. Only on the front panel is accessible, go to Main Menu -> System -> Optional function -> External board type -> IP in
2. Switch off the unit, and then switch it on again. Then the unit will become IP in, and the FACTORY DEFAULT setting will not change this IP direction. And at the same time, the menu structure on front panel & HDMS (the PC management software) will be changed accordingly.
To receive a multicast/unicast stream:
1. Go to the Main menu -> Input -> Ethernet
2. Set the IP address & parameters for the IP hardware board, Stream IP address -> enter the IP address for this IP hardware board (should be the same network section of the Stream Gateway, this depends on the characteristic of the gateway) Stream Netmask -> enter the network submask for this IP hardware board Stream Gateway -> enter the Gateway address for this IP hardware board Stream MAC addr -> Show the MAC address of this IP hardware board, read only.
3. Set the parameters for the incoming IP stream. On the same sub menu: Multicast IP address -> enter the multicast IP address for the incoming stream Multicast UDP port -> enter the port number of the incoming stream Protocol -> enter the protocol of the incoming stream, DCH-510P™ supports UDP and RTP. Output Smoothing -> Clock recover method from IP incoming stream, MUST set to Auto (both Auto & Fixed rate are for experimental test only). TS Bit Rate -> set to the bit rate of incoming stream in experimental test, this value will be ignored by DCH-510P™ if “Output Smoothing = Auto” in previous step.
4. After previous steps, DCH-510P™ will capture the incoming IP stream immediately. Normally it takes 30-60 seconds to lock the stream. You can go to the Main menu -> inputs -> Status-> IP IN to check the bit rate of incoming stream.
5. Finally, if user wants to watch TV decoded from IP incoming stream on the output of DCH­510P™, don’t forget to set the decoder portion of DCH-510P™ to select IP as the program source.
DCH-510P™ User Guide V1.1
24
7.2 How to set the Unicast/Multicast output
If the IP hardware board is configured as IP Input, please follow below procedure to change it to IP output:
1. Only on the front panel is accessible, go to Main Menu -> System -> Optional function -> External board type -> IP Out
2. Switch off the unit, and then switch it on again. Then the unit will become IP Out, and the FACTORY DEFAULT setting will not change this IP direction. And at the same time, the menu structure on front panel & HDMS (the PC management software) will be changed accordingly.
To set Unicast/Multicast output, please follow the procedure below:
1. Go to the Main menu -> Output -> Ethernet
2. Set the IP address & parameters for the IP hardware board: Stream IP address -> enter the IP address for this IP hardware board (should be the same network section of the Stream Gateway, this depends on the characteristic of the gateway) Stream Netmask -> enter the network submask for this IP hardware board Stream Gateway -> enter the Gateway address for this IP hardware board Stream MAC address -> Show the MAC address of this IP hardware board, read only.
3. Set the universal parameters for the output IP stream. On the same sub menu: Gate MAC address -> here the MAC address must be set as the MAC address of the Gateway where DCH-510P™ is located. Protocol -> enter the protocol of the output stream, DCH-510P™ supports UDP and RTP. TS Pkts per UDP -> set the quantity of TS packages that will be carried IP package. The range goes from 1 ~ 7 Time to Live -> set the TTL for the output IP package. Type of Service -> set the type of service for the output IP stream Source -> set the wanted stream output via IP. Mode -> Set the IP output mode as IPTV mode or DVB mode.
4. If the mode is set to be DVB mode, please follow below procedure ‘DVB mode’. If the mode is set to be IPTV mode, please go to procedure ‘IPTV mode’ directly.
DVB mode:
Unicast/Multicast Setup -> set the address and port parameters for the IP stream. Press Enter to go to the submenu. As below:
Multicast IP -> enter the multicast IP address for the output stream.
Multicast UDP Port -> enter the port number of the output stream.
Target Mac address-> set the MAC address of the receiving device. The parameter will be
used only when the receiving device is located under the same gateway. The parameter will be ignored by DCH-510P™ if the receiving device is located under other remote network or under different gateway.
DCH-510P™ User Guide V1.1
25
IPTV mode:
Unicast/Multicast Setup -> Press Enter to go to the submenu. As shown below:
Max Channels -> set the quantity of multicast/unicast channels. Channel 0 -> set the private parameters for Multicast / Unitcast channel 0. Press Enter to go to
the submenu.
0-Unicast/Multicast IP -> enter the multicast IP address for the output stream.
0-Unicast/Multicast Port -> enter the port number of the output stream.
0-Target MAC address -> set the MAC address of the receiving device. The parameter
will be used only when the receiving device is located under the same gateway. The parameter will be ignored by DCH-510P™ if the receiving device is located under other remote network or under different gateway.
0-Switch -> turn on/off channel 0.
0-Program -> select the programs that want to be outputted via channel 0.
For other channels, please refer to IPTV mode settings.
8. Control with Web Server
To control the unit via Web server, type in the unit IP address in the web browser. Default username and password are as following.
Username: root Password: 12345
DCH-510P™ User Guide V1.1
26
DCH-510P™ User Guide V1.1
27
DCH-510P™ User Guide V1.1
28
DCH-510P™ User Guide V1.1
29
DCH-510P™ User Guide V1.1
30
9. Statement of Conformity
state that our products, where they bear the CE marking illustrated above, are in conformity with the following standards:
EN 55022:2006 + A1:2007 Electromagnetic compatibility for equipment –
Cabled
distribution systems for television and sound signals.
EN 55024:1998 + A1:2001 + A2:2003 Information technology equipment – Immunity characteristics –
Limits and methods of measurement
EN 61000-3-2:2006 Electromagnetic compatibility Limits –
Limits for harmonic
current emissions (equipment input current <= 16 A per phase).
EN 61000-3-3:2008 Electromagnetic compatibility Limits –
Limitation of voltage
changes, voltage fluctuations and flicker in public low-
voltage
supply systems, for equipment with rated current <= 16 A p
er
phase and not subject to conditional connection.
EN 60950-1:2006 + A11:2009 Information technology equipment – Safety –
Part 1: General
requirements
This regards to the following Teracue products: DCH-510P-S2, DCH-510P-S2-IP DCH-510P-C, DCH-510P-C-IP DCH-510P-T, DCH-510P-T-IP DCH-510P-T2, DCH-510P-T2-IP
Compliance to those standards are required for the following Directives:
- Directive 2004/108/EC Electromagnetic Compatibility
- Directive 2006/95/EC Low Voltage
Loading...