TENSITRON BTX-1 Series, BTX-50-1, BTX-100-1, BTX-500-1, BTX-250-1 Operating Instructions Manual

Operating Instructions
BTX-1 Series Digital
Band Tension Meter
TABLE OF CONTENTS
1. WARRANTY POLICY ..................................................................................................... 3
2. SPECIFICATIONS .......................................................................................................... 4
3. SAFETY AND MAINTENANCE ....................................................................................... 5
4. INSTRUMENT FEATURES ............................................................................................. 6
Calibration and Accuracy ........................................................................................ 6
Add-On Options ...................................................................................................... 6
o - A Analog Output option ................................................................................ 6
o - E RS-232 Serial Output option ...................................................................... 6
Features of all Instruments .................................................................................... 6
5. BASIC OPERATION ....................................................................................................... 7
Charging Instrument Batteries ............................................................................... 7
Quick Start Instructions .......................................................................................... 8
Engaging Instrument onto Band ............................................................................. 9
6. DISPLAY SCREENS ...................................................................................................... 10
SETUP Screen ....................................................................................................... 10
o LCD Refresh Rate ............................................................................................. 10
o Data Averaging ................................................................................................ 10
o Custom Names ................................................................................................ 10
o Re-Cal Tension: See description at the end of this booklet. ............................ 11
o Audio ............................................................................................................... 11
o Backlight .......................................................................................................... 11
o Set-Point Menu ............................................................................................... 11
o Version ............................................................................................................ 12
DATA LOGGING Screen ......................................................................................... 12
o View Data Stats ............................................................................................... 12
o View Data Log .................................................................................................. 12
o Clear Single Point Log ...................................................................................... 12
TENSION UNITS Screen ......................................................................................... 12
SELECT MATERIAL Screen ..................................................................................... 12
7. ADVANCED OPERATION ............................................................................................ 12
General Calibration Precautions .......................................................................... 12
Check Accuracy .................................................................................................... 13
Calibrate Instrument ............................................................................................ 13
Proprietary Notice
This document contains proprietary information which may not be reproduced in whole or in part without the written permission of Tensitron, 733 South Bowen Street, Longmont, CO 80501.
Tensitron reserves the right to make instrument changes and improvements which may not be reflected in this document. Portions of this document may have been updated to include the latest hardware or firmware version, if applicable. We recommend that this document be read in its entirety before any attempt is made to operate the instrument.
Thank You . . .
For purchasing another fine product from Tensitron
If you have any questions or need assistance, please call us at
303-702-1980 or find us online at www.tensitron.com
1. WARRANTY POLICY
STANDARD EQUIPMENT WARRANTY
Tensitron warrants that all Tensitron-manufactured equipment will be free of any defect in materials or
workmanship for the period of (1) year. Warranty begins from the date of shipment from a Tensitron facility. The warranty is extended to customers and applies to all Tensitron-manufactured equipment purchased, installed, and used for the purpose for which such equipment was originally designed. The above warranties cover only defects arising under normal use and do not include malfunctions or failures resulting from misuse, abuse, neglect, alteration, problems with electrical power, usage not in accordance with product instructions, acts of nature, or improper installation or repairs made by anyone other than Tensitron or a Tensitron­authorized, third-party service provider. Shipping costs to and from Tensitron are not included in the warranty coverage.
2. SPECIFICATIONS
Full Scale Accuracy
For the accuracy of each BTX-1 model, see Section 4.
Power Requirements
For Instrument Input: 9 VDC…2.2A For AC Adapter: 100-240V~50-60Hz 0.48A
Power Supply operates with input voltages from 100 –240V and includes several interchangeable adapters allowing use with European, U.S., Australian, English and other plug configurations.
Battery
Battery: Rechargeable NiMH, custom proprietary design Battery lasts approximately 12 hours between charges, depending on backlighting intensity.
Operating Temperature
32º F to 120 º F. If these values are exceeded, battery charge/discharge rates will decline. However, this could be offset by using the power supply. Charging in direct sunlight or near a heat source will not produce a full charge and may permanently damage battery pack.
Storage Temperature
20º F to 158º F. (Instrument and Charger)
Ambient Humidity
10% to 90% non-condensing
Weight, Dimensions
BTX-1: Weight 3.1 lb. Dimensions 3.8” x 11.4” x 4.7” (See Figure 1)
Environment
Indoor or outdoor use, dust-free environment.
Figure 1: BTX-1 Dimensions
3. SAFETY AND MAINTENANCE
WARNING: When using cordless, electronic instruments, always follow basic
safety precautions to reduce the risk of fire, electric shock and personal injury
USE ONLY A TENSITRON POWER SUPPLY TO AVOID DAMAGE
TO INSTRUMENT.
READ AND SAVE ALL INSTRUCTIONS. Before use, ensure all users
read and understand this manual, as well as labels packaged with or attached to the instrument.
Know your instrument. Read this manual carefully to learn your tension meter’s applications and limitations, as well as potential hazards associated with this type of instrument.
Avoid dangerous environments. Do not use your instrument in explosive atmospheres (gaseous fumes, dust or flammable materials). Do not submerge your instrument in liquids.
Use the right tool or instrument. Do not use this instrument to do a job for which it is not recommended.
Check for damaged parts. Inspect instrument before use. Check for any binding of moving parts, improper mountings, broken parts and any other condition that may affect operation. Do not use a damaged instrument. Tag damaged instrument “DO NOT USE” until repaired. For repair, send instruments directly to Tensitron.
Guard against electric shock.
Maintain instrument carefully. Keep handles dry, clean and free from oil
and grease. Do not lubricate. All roller bearings are sealed.
Do not use instrument if it has received a sharp blow, been dropped or damaged in any way. Do not disassemble. Incorrect reassembly may result in damage to the instrument and risk of electric shock and fire. Return damaged instruments to Tensitron for repair.
WARNING: Only use battery pack assemblies provided by Tensitron with your meter. Other types of batteries might explode, causing personal injury and damage. Unplug charger when not in use.
Tensitron recommends calibration by the manufacturer at one-year intervals, or sooner if the meter is worn, damaged, or reading incorrectly. However, it is the user’s responsibility to establish a suitable calibration interval, considering the user’s accuracy requirements, requirements set by contract or regulation, and environmental factors such as frequency and conditions of the meter’s use.
Loading...