ASSEMBLY INSTRUCTIONS & PARTS MANUAL #1960912
Z-Line Medium Profile Boltless Shelving
Installation Instructions
Tennsco Corp., Dickson, TN 37056-1888 • (615) 446-8000
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE!
Congratulations on your purchase of ZLine Medium Profile Boltless Shelving
from Tennsco! Z-Line's interlocking
keyhole design not only makes
installation fast and easy but eliminates
the need for clips, gussets, sway braces
or other hardware commonly used in
conventional shelving. This allows
completely free access to your stored
materials from all sides of the unit.
Z-Line Medium Profile Shelving is
available in a variety of heights, depths
and widths for virtually any application.
And starter and adder units allow for
joining your shelving units together.
SHELF LOAD CAPACITIES
36" wide units 1000 lbs. per shelf
48" wide units 850 lbs. per shelf
48" heavy duty 1000 lbs. per shelf
GENERAL SAFETY INFORMATION
Some parts may have sharp edges. CARE
must be taken when handling pieces to
avoid injury. For safety, wear a pair of work
gloves when assembling or performing any
maintenance on shelving.
LIMITED WARRANTY
Tennsco warrants goods purchased hereunder to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment,
hereunder. This warranty shall not apply in the event goods are damaged as a result of misuse, abuse, neglect, accident, improper application, modification
or repair by persons not authorized by Seller, where goods are damaged during shipment, or where the date stamps on the goods have been defaced, modified
or removed. UNLESS CONSIDERED UNENFORCEABLE OR UNLAWFUL UNDER APPLICABLE LAW:
a. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY EXCLUDED:
b. BUYERS REMEDY, IF ANY, FOR ANY DEFECTIVE GOODS SHALL BE LIMITED TO A REFUND BY SELLER OR REPLACEMENT OF THE GOODS
AT SELLER’S OPTION, AND SHALL IN NO EVENT INCLUDE DAMAGES OF ANY KIND, WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE.
NO GOODS ACCEPTED FOR RETURN WITHOUT PRIOR APPROVAL. Seller shall have the right to inspect any goods claimed to be defective at Buyers place
of business or require Buyer to return the goods to Seller for inspection on Seller’s premises. Transportation charges covering returned goods will be borne
by Seller only if such goods are proven to be defective, are covered by this warranty and are returned within the warranty period stated above.
TENNSCO CORP., P.O. BOX 1888, DICKSON, TN 37056-1888
(615) 446-8000 (800) 251-8184
PK-1960912
ASSEMBLY OF BOLTLESS MEDIUM PROFILE SHELVING
Tools Needed: A rubber mallet for seating the shelf supports into the uprights.
Two people are recommended for assembly. Approximate assembly time: 15 to 30 minutes per shelving section.
1. The reference numbers used throughout this
sheet refer to the illustration on the back cover.
This is to help you to identify the various parts as
they are mentioned.
2.
Depending upon whether
Angle Post
(EUR)
you are assembling a
single unit or an adder
unit, you may have one
or both of the styles of
upright shown at right:
"T" Post
(ZTP)
A single unit uses EUR posts for all four uprights,
as shown below in Figure A. If you plan on assem-
bling multiple sections, however, you should build
the starter unit with two ZTP "T" posts on
one end, which will
provide common posts
for adjacent sections
as shown in Figure B.
A. Single unit with four
EUR
B. Two or more units with Angle Posts (EUR) on
each end and "T" Posts (ZTP) connecting each unit.
Angle Posts (EUR).
ZTP
3. With help from an associate, or using a wall for
support, connect two EUR uprights (Ref. No. 1a)
together with one front-to-back support (Ref. No. 2).
Be sure the front-to-back
support is fully
seated in the
keyhole
slots, as
shown.
NOTE: The
uprights
must be
positioned
so that the
narrow part
of the keyhole is
toward the
floor, as
shown in the inset.
NOTE: Inset is shown
from opposite side.
IMPORTANT: The
shelf support MUST be
inserted so that the flat
surface is on top as
shown in profile at left!
EUR
4. Place a second front-to-back
shelf support in the
bottom keyholes of
the two uprights.
This forms
one end
of your
shelving
unit.
5. Repeat steps 3 and
4 to construct a second set of unit ends.
NOTE: If you are planning to install an adder
unit, this second end should consist of ZTP
Uprights (Ref. No. 1b) to act as an intermediate
assembly. Carefully
re-read through
step 2 to better
understand
this.
NOTE: If
assembling a
ZTP upright
assembly (for an
adder unit), place
the front-to-back
shelf supports on
both sides of the
"T" post, at all