Tenmars TM-601N, TM-603, TM-604 User Manual

Page 1
3-Phase / Rotation
User’s
Manual
Motor Tester
TM-601N / 603 / 604
Page 2
Page 3
CONTENTS
1. Preface......................................................... 2
2. Application ................................................... 2
3. Features:...................................................... 3
4. Panel display................................................ 3
5. How to operate............................................. 4
5.1 How to test the 3 phases of AC .................... 4
5.2 How to test the motor’s direction of rotation . 5
6. Easy test ...................................................... 9
7. Electrical specifications ...............................11
8. Accessories included: .................................11
9. Safety precautions and procedures ........... 12
10. The following symbols are used: ................ 14
11. Safety and maintenance standards............ 15
12. Battery Replacement.................................. 16
13. Service ....................................................... 19
14. End of life ................................................... 20
Page 4
TM-601N/603/604
1. Preface
Thank you for buying our excellent product. Products available on the market are not very user-friendly: their test AC phase and motor phase are separated from each other, have two sockets (to be plugged out before use), etc. When you use the you will not have these troubles anymore, and time is saved. So enjoy it !
2. Application
Test for poles of the 3-phase power
source, L1/A, L2/B and L3/C, and identify which phase for which wire.
Determine the 3-phase motor’s direction
of rotation (clockwise or counterclockwise) and the circuit status of the motor wires.
EN-2
Page 5
TM-601N/603/604
3. Features:
In each test, Push “ ” button turn on
the meter, push “ off the meter. or auto shut off after 15 minutes (
Check the 3 wires of the power cord, L1,
L2 and L3 through the 3 red lamps, which indicate if each wire is connected well.
Check if L1, L2 and L3 are in place, the 3
motor wires, the motor’s direction of rotation, and the ER red/green OK indicators.
When the battery is low, an indicator will
turn ON to remind you to replace it.
hold the power button and check the
panel indicator. (TM-603/604)
Two UL 500mA/700V fuse .(TM-601N) Waterproof resist IP67.(TM-601N)
TM-601N)
”button again to turn
4. Panel display
3 red lamps(L1, L2 and L3) ER red/green OK indicators. Low battery indicator (see step 10)
EN-3
Page 6
TM-601N/603/604
5. How to operate
5.1. How to test the 3 phases of AC
Let your crocodile clip clamp the 3-phase power terminal. In each test, hold the power button and check the indicators on the panel. If L1, L2 and L3 are lit, it means normal.
(In this case, skip to step 2.) If one of them remains unlit, L1 for example, it means the wire for L1 is disconnected or in power failure mode. You may check visually or with a multimeter if the wire is connected well.
Next, check if the red or green lamp is lit.
If it is the green lamp, it suggests L1, L2 and L3 are correct for their phases. (In this case, skip to step 6). If it is the ER red lamp, it means L1, L2 and L3 are wired incorrectly. You must correct them before proceeding to step 3.
Exchange L2 and L3. If the green lamp
goes ON, it means the 3 phases are correct. (In this case, skip to step 6.) If the red lamp ER goes ON, it means the 3 phases are wired incorrectly. You must
EN-4
Page 7
TM-601N/603/604
correct them before going to the next step.
Exchange L1 and L3. If the green lamp
goes ON, it means the 3 phases are correct. (In this case, skip to step 6.) If the red lamp ER goes ON, it means the 3 phases are wired incorrectly. You must correct them before going to the next step.
Exchange L1 and L2. If the green lamp
goes ON, it means the 3 phases are correct. (In this case, skip to step 6.)
Note the definition for L1, L2 and L3
each.
5.2. How to test the motor’s direction of rotation
Make sure the motor’s power source has
been removed.
Connect the test wire to the motor
terminal. In each test, press the power button, then check the indicators on the panel: when the motor is not turning, the red lamp is ON.
The green lamp goes ON when the motor
EN-5
Page 8
TM-601N/603/604
turns clockwise, and the red lamp goes ON when it turns counterclockwise. (Normal; skip to step 8.) If the motor turns clockwise and counterclockwise and the red lamp remains ON (the red and green lamps do not go ON alternately), this suggests one wire is disconnected or not connected well. Please measure the motor’s 3 wires with a multimeter and check if there is a disconnection between any 2 wires. (If the motor is disconnected, change it.)
The green lamp goes ON when the motor
turns clockwise, and the red lamp turns ON when it turns counterclockwise. This suggests the wiring of L1, L2 and L3 is normal. (In this case, skip to step 8.) If the red lamp goes ON when the motor turns clockwise, and the green lamp goes ON when it turns counterclockwise, this indicates that the wiring sequence must be corrected. Go to step 5.
Exchange L2 and L3. The green lamp
goes ON when the motor turns clockwise,
EN-6
Page 9
TM-601N/603/604
and the red lamp goes ON when it turns counterclockwise, this suggests the wiring of L1, L2 and L3 is normal. (In this case, skip to step 8.) If the red lamp goes ON when the motor turns clockwise, and the green lamp goes ON when it turns counterclockwise, this indicates the wiring sequence must be corrected. Go to step 6.
Exchange L1 and L3. If the green lamp
goes ON when the motor turns clockwise, and the red lamp goes ON when it turns counterclockwise, skip to step 8. If the red lamp goes ON when the motor turns clockwise, and the green lamp goes ON when it turns counterclockwise, this indicates the wiring sequence must be corrected. Go to step 7.
Exchange L1 and L2. If the green lamp
goes ON when the motor turns clockwise, and the red lamp goes ON when it turns counterclockwise, this suggests the wiring of L1, L2 and L3 is normal. (In this case, skip to step 8.)
EN-7
Page 10
TM-601N/603/604
Once the green lamp goes ON when the
motor turns clockwise, and the red lamp goes ON when it turns counterclockwise, the 3 phases are correct. Then the motor’s R.S.T. can be connected to the power system’s L1, L2 and L3. Now your motor can run correctly.
EN-8
Page 11
TM-601N/603/604
6. Easy test
6.1.1. Motor turning test
6.1.2. Wiring and lamps
EN-9
Page 12
TM-601N/603/604
Off On not defined
Phase indication
L1 L2 L3
phase rotation
Rotate right
Power on
Rotate left
L1 missing
L2 missing
L3 missing
EN-10
Page 13
TM-601N/603/604
7. Electrical specifications
Battery life : about 50 hours Operating Temperature : 5~40,80%RH Storage temp. & RH : -10 ~60℃℃,70%RH. Overvoltage category :
CAT IV 600V, CAT III 1000V.
Dimensions (with holster) : 143×68×35 mm. Weight (including battery) : about 150g. Inter phase voltage : 45V AC up to 600 AC. Signal Frequency Range : 45 to 400 Hz. Test Currents (In per phase) less than :
3.5 mA
Motor POWER6W ~160W
8. Accessories included:
User manual. 9V battery(NEDA 1604 IEC 6F 22 JIS
006P)*1carrying case.
Test leads should be 4 feet long*3.
CE120cm ( 4 feet ).
Test leads should be removable and
have alligator clips*3.
EN-11
Page 14
TM-601N/603/604
9. Safety precautions and
procedures
This instrument conforms with safety Standard EN 61010-1 related to electronic measuring instruments. For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol
CAUTION
For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol
.
When taking measurements:
Avoid doing that in humid or wet places.
Avoid doing that in rooms where explosive gas, combustible gas, steam or excessive dust is present.
.
EN-12
Page 15
TM-601N/603/604
Keep you insulated from the object under
test. Do not touch exposed metal parts such as test lead ends, sockets, fixing objects, circuits etc. Avoid doing that if you notice anomalous
conditions such as breakages,
deformations, fractures, leakages of
battery liquid, blind display etc. Be particularly careful when measuring
voltages exceeding 20V to avoid risks of
electrical shocks.
EN-13
Page 16
TM-601N/603/604
10. The following symbols are
used:
°C AUTION - refer to the instruction manual - an improper use may damage the instrument or its components
Danger high voltage: risk of electric shock
Double insulated meter
AC voltage or current
DC voltage or current
Earth
EN-14
Page 17
TM-601N/603/604
11. Safety and maintenance
standards
The instrument complies with : UL61010-1,and CSA C22.2 No.61010-1 (between ground and input terminal) and EN 61010-1(2001) and EN61557.
Operating altitude : below 2,000m. Operating environment: for indoor use,
expose to pollution level II. This is a precision device. During use or
storage, do not go beyond its spec. to
prevent any possible damage or danger. Do not put this device in direct sunlight or
where it is hot and/or damp. Remember to turn OFF the power after
use. For long storage, remove the battery
to prevent the battery from leaking to
cause damage to the parts inside. Clean the device with a dry soft cloth.
Wet cloths, liquid and water are
prohibited.
EN-15
Page 18
TM-601N/603/604
12. Battery Replacement
Battery Replacement
When the symbol Low battery LED is
displayed, batteries need replacement.
Before replacing batteries disconnect the test leads from any energized circuits to avoid electrical shocks.
Turn OFF the meter and disconnect the test leads from the input terminals. Unscrew the battery cover and remove
the battery. Insert a new battery of the same type (9V
NEDA1604, JIS006P, IEC6F22)
observing the proper polarity, re-screw
the battery cover and reposition the
protective holster.
CAUTION
EN-16
Page 19
TM-601N/603/604
Conditions
This instrument is guaranteed for one year against material or production defects, in accordance with our general sales conditions. During the warranty period the manufacturer reserves the right to decide either to repair or replace the product. Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it. Do not forget to enclose a report describing the reasons for returning (detected fault). Use only original packaging. Any damage occurred in transit due to non original packaging will be charged anyhow to the customer.
The warranty doesn’t apply to:
Accessories and batteries (not covered
Repairs made necessary by improper
by warranty).
use (including adaptation to particular
applications not foreseen in the
instructions manual) or improper
EN-17
Page 20
TM-601N/603/604
combination with incompatible
accessories or equipment. Repairs made necessary by improper
shipping material causing damages in
transit. Repairs made necessary by previous
attempts for repair carried out by non
skilled or unauthorized personnel. Instruments for whatever reason
modified by the customer himself without
explicit authorization of our Technical
Dept.
The contents of this manual may not be reproduced in any form whatsoever without the manufacturer’s authorization.
Our products are patented and our logotypes registered. We reserve the right to modify specifications and prices in view of technological improvements or developments which might be necessary.
EN-18
Page 21
TM-601N/603/604
13. Service
Shouldn’t the instrument work properly, before contacting your distributor make sure that batteries are correctly installed and working, check the test leads and replace them if necessary. Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it. Do not forget to enclose a report describing the reasons for returning (detected fault). Use only original packaging. Any damage occurred in transit due to non original packaging will be charged anyhow to the customer. The manufacturer will not be responsible for any damage to persons or things.
EN-19
Page 22
TM-601N/603/604
14. End of life
Caution : this symbol indicates
that equipment and its accessories shall be subject to a separate collection and correct disposal.
EN-20
Page 23
Page 24
Professional Electrical and
Environment Test & Measurement
Instruments:
Battery Capacity / Impedance Tester, TACHO
Meter ,LED light meter, Temperature & Humidity
meter ,Infrared Thermometer, Sound level
meter ,Light meter, EMF meter, UV Light meter,
RF meter, Hot wire Anemometer, CO meter
Anemometer, Lan cable tester, CO
Solar power meter, Radiation meter,
Clamp meter, Multimeter, Phase Rotation test,
Digital Insulation teste
2
r
meter,
Our products of high quality are selling
well all over the world
TENMARS ELECTRONICS CO., LTD
6F, 586, RUI GUANG ROAD, NEIHU,
TAIPEI 114, TAIWAN.
E-mail: service@tenmars.com
http://www.tenmars.com